KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
FEATURES
· 0...-1 to 0...400 bar
0...-15 to 0...6000 psi
gage
1
or absolute
· For many industrial gases and liquids
· 0...10 V, 0.5...4.5 V, 0...5 V and
4...20 mA output
· Field interchangeable
· For industrial use
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L), ceramic Al
2
O
3
, NBR
9
,
TPE
9
Housing:
stainless steel, protection class IP 65 (according to
DIN EN 60529) respectively NEMA 4X
1
SPECIFICATIONS
11,12
Maximum ratings
ELECTRICAL CONNECTION
0...10 V, 0.5...4.5 V, 0...5 V output
Supply voltage (reverse polarity protection)
KTx6...0
12...30 V
KTx6...6, KTx6...7
9...30 V
2
KTx6...4
9...30 V
Maximum load current (source)
KTx6...0, KTx6...6, KTx6...7
Temperature limits
Storage
Operating
Compensated
Humidity limits
Vibration (5 to 500 Hz)
Mechanical shock
Proof pressure
3
400 bar (6000 psi)
all others
December 2008 / 550
+Vs
1
Vout
3
-Vs
2
12 (9) to 30 V
sensor
V
1 mA
GND
-55 to 100°C
-40 to 100°C
0 to 70°C
0 - 95 %RH
10 g
RMS
50 g
4...20 mA output
+Vs
1
N/C
3
-Vs
2
9 to 30 V
sensor
V
R
L
GND
1.5 x rated pressure
2 x rated pressure
1/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
V
S
= 15 V, R
L
> 100 kΩ, t
amb
= 25°C
Characteristics
Operating pressure
KTE6001...
KTE6N01G...
KTE6P01G...
KTE6002...
KTE6005...
KTE6010...
KTE6016...
KTE6020...
KTE6025...
KTE6035...
KTE6050...
KTE6070...
KTE6100...
KTE6150...
KTE6200...
KTE6300...
KTE6400...
KTU6015...
KTU6N15G...
KTU6P15G...
KTU6030...
KTU6050...
KTU6100...
KTU6200...
KTU6300...
KTU6500...
KTU61K0...
KTU61K5...
KTU62K0...
KTU63K0...
KTU64K5...
KTU66K0...
Offset
Span
Offset
Span
> 200 bar (3000 psi)
all others
Min.
0
-1
-1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-15
-15
0
0
0
0
0
0
0
0
0
0
0
0
Typ.
Max.
1
1
0
2
5
10
16
20
25
35
50
70
100
150
200
300
400
15
15
0
30
50
100
200
300
500
1000
1500
2000
3000
4500
6000
0.05
0.05
Unit
bar
p si
Thermal effects
(0 to 70°C)
4
Thermal effects
(-40 to 0°C, 70 to 100°C)
Non-linearity, hysteresis (BSL)
and repeatability
5
Long term stability
6
Output noise (0 < f < 1 kHz)
Response time (10 to 90 %)
Power supply rejection
0.02
0.02
0.03
0.03
±0.2
±0.1
±0.3
±0.04
1
%FSO/°C
±0.4
±0.3
%FSO
5
ms
%FSO/V
Offset
Span
KTx6...0, ...6, ...7
KTx6...4
KTx6...0, ...6, ...7
KTx6...4
0.002
0.05
0.002
0.08
December 2008 / 550
2/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output
(V
S
= 15 V, R
L
> 100 kΩ, t
amb
= 25°C)
Characteristics
Zero pressure offset
Full scale span
7
Output impedance
Current consumption (no load)
KTx6N...
all others
KTx6N...
all others
Min.
4.9
4.9
9.9
Typ.
5
0.03
5
10
Max.
5.1
0.1
5.1
10.1
25
Unit
V
Ω
mA
3
5
0.5...4.5 V output
(V
S
= 15 V, R
L
> 100 kΩ, t
amb
= 25°C)
Characteristics
Zero pressure offset
Full scale span
7
Output impedance
Current consumption (no load)
KTx6N...
all others
KTx6N...
all others
Min.
2.450
0.450
1.950
3.950
Typ.
2.5
0.5
2
4
Max.
2.550
0.550
2.050
4.050
25
Unit
V
Ω
mA
3
5
0...5 V output
(V
S
= 15 V, R
L
> 100 kΩ, t
amb
= 25°C)
Characteristics
Zero pressure offset
Full scale span
7
Output impedance
Current consumption (no load)
KTx6N...
all others
KTx6N...
all others
Min.
2.45
2.45
4.95
Typ.
2.5
0.03
2.5
5.0
Max.
2.55
0.08
2.55
5.05
25
Unit
V
Ω
mA
3
5
4...20 mA output
(V
S
= 15 V, R
L
= 100
Ω,
t
amb
= 25°C)
Characteristics
Zero pressure offset
Full scale span
7
Power consumption (I
L
= 20 mA)
KTx6N...
all others
KTx6N...
all others
Min.
11.9
3.9
7.9
15.9
Typ.
12.0
4.0
8.0
16.0
250
Max.
12.1
4.1
8.1
16.1
Unit
mA
mW
December 2008 / 550
3/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
OUTPUT CHARACTERISTICS
0...10 V output version
10
Vout
V 9
8
7
6
5
4
3
2
1
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 %
operating pressure
KTx6P...
all other
KTx6N...
0.5...4.5 V output version
10
Vout 9
V
8
7
6
5
4
3
2
1
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 %
operating pressure
KTx6P...
all other
KTx6N...
0...5 V output version
10
Vout
V 9
8
7
6
5
4
3
2
1
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 %
operating pressure
all other
KTx6P...
KTx6N...
4...20 mA output version
20
Iout 18
mA
16
14
12 KTx6P...
10
8
6
4
2
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 %
operating pressure
all other
KTx6N...
LOAD LIMITATION
4...20 mA output version
1400
Ohm
1200
1000
800
op
e
ra ratin
ng g
e
RECOMMENDED ACCESSORY
Plug
DIN EN 175301-803 A
and profile washer included
in delivery. For a complete connector/cable assembly
use order no.
ZK000110-x
(x=cable lenghts in m).
50
34
600
400
200
0
5
9
Profile washer
M3
31
16 20
25 30 V
supply voltage
dimensions in mm
Note:
For proper function of all gage devices the
gage port must be vented to the atmosphere
through the connector/cable assembly.
4/6
December 2008 / 550
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
OUTLINE DRAWING
KTE6...T
4.5
(0.18)
HEX 27 (1.06)
G1/2"
(1/2" BSP)
23 (0.90)
17
(0.67)
8.5 (0.33)
27.0 (1.06)
diam.
NOM 68 (2.68)
12
(0.47)
vent hole
3
6.0
2
1
KTE6...Q
4.5
(0.18)
HEX 27 (1.06)
12
(0.47)
NOM 68 (2.86)
8.5 (0.33)
G1/4"
(1/4" BSP)
27.0 (1.06)
diam.
12
(0.47)
vent hole
3
2
1
KTE6...L
4.5
(0.18)
HEX 27 (1.06)
17
(0.67)
NOM 68 (2.68)
8.5 (0.33)
27.0 (1.06)
diam.
12
(0.47)
vent hole
3
1/4"NPT
2
1
KTE6...O (flush mount)
12
(0.47)
13
(0.51)
NOM 68 (2.68)
8.5 (0.33)
12
(0.47)
vent hole
3
Hex 32 (1.26)
27.0 (1.06)
diam.
G3/4"
2
1
mass:
210 g
December 2008 / 550