5 W U l t r a min ia ture Medical Enc apsu la ted S witc her s
Universal 90-264VAC Input
High Efficiency
Improved EMI Performance
5656VDC Isolation
EMA5
series
Single , Dual and Triple Outputs
UL60601-1, EN60601-1 & IEC60601-1
Model Number
Output Voltage
Output Amps FL (peak)
Ripple/Noise
Efficiency
SINGLE OUTPUT - PCB Mount
ESMA-5000
3.3 VDC
ESMA-5001
5 VDC
ESMA-5022
9 VDC
ESMA-5002
12 VDC
ESMA-5003
15 VDC
ESMA-5018
18 VDC
ESMA-5005
24VDC
SINGLE OUTPUT - Chassis Mount
ESMC-5000
3.3 VDC
ESMC-5001
5 VDC
ESMC-5022
9 VDC
ESMC-5002
12 VDC
ESMC-5003
15VDC
ESMC-5018
18 VDC
ESMC-5005
24VDC
SINGLE OUTPUT - DIN Rail Mount
ESMC-5000/DRL
3.3 VDC
ESMC-5001/DRL
5 VDC
ESMC-5022/DRL
9 VDC
ESMC-5002/DRL
12 VDC
ESMC-5003/DRL
15VDC
ESMC-5018/DRL
18 VDC
ESMC-5005/DRL
24VDC
1.25A (1.56A)
1A (1.5A)
0.55 (0.82)
0.42A (0.63A)
0.33A (0.5A)
0.27 (0.4A)
0.23A (0.35A)
1.25A (1.56A)
1A (1.5A)
0.55 (0.82)
0.42A (0.63A)
0.33A (0.5A)
0.27 (0.4A)
0.23A (0.35A)
1.25A (1.56A)
1A (1.5A)
0.55 (0.82)
0.42A (0.63A)
0.33A (0.5A)
0.27 (0.4A)
0.23A (0.35A)
165mV pk-pk
100mV pk-pk
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
165mV pk-pk
100mV pk-pk
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
165mV pk-pk
100mV pk-pk
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
60%
70%
70%
73%
74%
75%
76%
60%
70%
70%
73%
74%
75%
76%
60%
70%
70%
73%
74%
75%
76%
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
5 W U l t r a min ia ture Medical Enc apsu la ted S witc her s
Universal 90-264VAC Input
High Efficiency
Improved EMI Performance
5656VDC Isolation
EMA5
series
Single ,Dual and Triple Outputs
UL60601-1, EN60601-1 & IEC60601-1
Model Number
Output Voltage
Output Amps FL (peak)
Ripple/Noise
Efficiency
DUAL OUTPUT - PCB Mount
EDMA-5006
±12 VDC
EDMA-5007
±15 VDC
DUAL OUTPUT - Chassis Mount
EDMC-5006
±12 VDC
EDMC-5007
±15 VDC
DUAL OUTPUT - DIN Rail Mount
EDMC-5006/DRL
±12 VDC
EDMC-5007/DRL
±15 VDC
TRIPLE OUTPUT - PCB Mount
ETMA-5009
5 ±12 VDC
ETMA-5011
5 ±15 VDC
TRIPLE OUTPUT - Chassis Mount
ETMC-5009
5 ±12 VDC
ETMC-5011
5 ±15 VDC
TRIPLE OUTPUT - DIN Rail Mount
ETMC-5009/DRL
5 ±12 VDC
ETMC-5011/DRL
5 ±15 VDC
±0.21A (±0.26A)
±0.17A (±0.21A)
±0.21A (±0.26A)
±0.17A (±0.21A)
±0.21A (±0.26A)
±0.17A (±0.21A)
0.53 ±0.1 A / 0.6 ±0.1 A
0.41 ±0.1 A / 0.45 ±0.1 A
0.53 ±0.1 A / 0.6 ±0.1 A
0.41 ±0.1 A / 0.45 ±0.1 A
0.53 ±0.1 A / 0.6 ±0.1 A
0.41 ±0.1 A / 0.45 ±0.1 A
±100 mV pk-pk
±100 mV pk-pk
±100 mV pk-pk
±100 mV pk-pk
±100 mV pk-pk
±100 mV pk-pk
50 ±75 mV pk-pk
50 ±75 mV pk-pk
50 ±75 mV pk-pk
50 ±75 mV pk-pk
50 ±75 mV pk-pk
50 ±75 mV pk-pk
71%
71%
71%
71%
71%
71%
63%
61%
63%
61%
63%
61%
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
5 W U l t r a min ia ture Medical Enc apsu la ted S witc her s
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
Leakage Current
90-264 VAC
47-63 Hz
20A@115V, 40A@230V Input
*
<500UA @ 264VAC, 50Hz
EMA5
2.28L” x 1.77W” x 0.83H”
3.77L” x 2.16W” x 1.0H”
3.77L” x 2.16W” x 1.35H”
Rynite, 94V-0 Rated
Encapsulated. Soft Pot
4 oz (112g) / 8.5 oz (238g)
11.5 oz (326g)
series
PHYSICAL SPECIFICATIONS
Size
PCB Mount
Chassis Mount
Din Rail
Case Material
Construction
Weight
PCB / CHA
Din Rail
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation (Note7)
See Selection Chart
Singles/Duals ± 3%,
Triple: 0.5 / ± 0.5% (max)
Line Regulation (Note 8)
Singles 0.1~1%, typ
Duals ± 0.3~1%, typ
Triple: 0.6 / ± 0.2% (max)
Cross Regulation (Note 11)
Duals 2%
Triple NA / ± 0.1%
Preset Accuracy (Note 9)
1%
Temperature Coefficient
±0.03%/°C
Ripple/Noise (Note 1, 2, 10)
See Selection Chart
Over Voltage Protection
Clamp
Over Temp. Protection
Latching, recover after cooling and
power is restored
Short Circuit Protection (Note 3) Indefinite
Hold Up Time
30 mS, typ (Nom. Input, 100% load)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature (Note 5)
Storage Temperature
Relative Humidity
EMC / EMI
MTBF
0 to +50°C (See Derate)
-25 to +71°C
*
0 to + 95%, non-cond
*
FCC/A, VDE 0871/A , CISPRB
(Mil Std 217, 25°C)
180,000 Hrs
NOTES
1. All measurements should be made directly at the terminals of the
power supply.
2. Ripple and Noise depend upon output voltage as specified par par-
ticular model.
3. Short Circuit Protection is self-recovering when overcurrent condition
is removed.
4. Isolation for up to 1minute duration.
5. Specified for free-air convection cooling.
6. Minimum load is NOT required for proper operation. However, auxil-
iary outputs should be reduced as a function of primary output minimum
load or load regulation will be higher.
7. Load regulation measured from 20% to FL.
8. Line regulation measured from 90VAC 264VAC.
9. Preset accuracy measured at nominal load, 120 VAC input.
10. O/P noise measured directly at pins/terminals at nom. load, 0.1uF
bypass, pk-pk @20MHz bandwidth.
11. Cross Reg-Triples: Measured at nom. load with the 5V output varied
between 60% and 100% of nim. load.
12. 100% Production Tested.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
GENERAL SPECIFICATIONS
Isolation (Note 4)
5656VDC Input-Output
3535VDC I/P-Ground
1414VDC O/P-Ground
See Selection Chart
100Khz, (fixed, typical)
UL60601-1, EN60601-1
EN55022
Efficiency
Switching Frequency
Safety
EMC
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
*
These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
5 W U l t r a min ia ture Medical Enc apsu la ted S witc her s
MECHANICAL DIMENSIONS - CHASSIS MOUNT
EMA5
series
4
1
2
3
5
6
7
8
9
Model
Type / Pin#
Single
ACN
N/C
ACL
N/C
-Vout
-Vout
+Vout
+Vout
N/C
Dual
ACN
N/C
ACL
N/C
-Vout
Com
Com
+Vout
N/C
Dual (5008) Triple
ACN
N/C
ACL
N/C
Com
Com
+5V
+12V
N/C
ACN
N/C
ACL
N/C
+5VRTN
+5Vout
-Vout
Com
+Vout
MECHANICAL DIMENSIONS - DIN RAIL
0.350 [8.89]
1
2
3
4
5
6
7
8
9
0.100 [2.54]
DIN Rail mounting kit available for Chassis-mount modules, specify part #
M-DRL-01. Kit includes mounting plate, DIN Rail cliip and assembly hardware.
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458