EEWORLDEEWORLDEEWORLD

Part Number

Search

SV400M1R50B1F31012

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 400V, 20% +Tol, 20% -Tol, 1.5uF, Through Hole Mount, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size60KB,2 Pages
ManufacturerYAGEO
Websitehttp://www.yageo.com/
Environmental Compliance  
Download Datasheet Parametric View All

SV400M1R50B1F31012 Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 400V, 20% +Tol, 20% -Tol, 1.5uF, Through Hole Mount, ROHS COMPLIANT

SV400M1R50B1F31012 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerYAGEO
package instruction,
Reach Compliance Codecompli
ECCN codeEAR99
capacitance1.5 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
dielectric materialsALUMINUM (WET)
leakage current0.046 mA
Manufacturer's serial numberSV
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-25 °C
Package shapeCYLINDRICAL PACKAGE
method of packingBULK
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)400 V
ripple current30 mA
surface mountNO
Delta tangent0.2
Terminal shapeWIRE
YAGEO CORPORATION
ALUMINUM ELECTROLYTIC CAPACITORS
Miniature Size Aluminum
Electrolytic Capacitors
SV
[ For adapter and power supply applications
Series ]
105°C Single-Ended Lead Aluminum Electrolytic Capacitors For High Frequency Applications
ELECTRICAL CHARACTERISTICS
Operating Temperature : -40° ~ +105°C
Working Voltage :
160V
-25° ~ +105°C
450V
10 ~ 150µF
Rate Capacitance Range : 22 ~ 220µF
Capacitance Tolerance : -20 ~ +20%
DC Leakage Current (µA) : I = 0.06 CV + 10(µA)
whichever is greater.( After 2 minutes application of rated voltage at 25°C )
Dissipation Factor : at 120 Hz, 25°C
DESCRIPTION
Used in switching regulator applications in com-
puters. Especially for high frequency.
Low impedance and E.S.R., high permissible ripple
current at high frequency and higher operating
temperature (-40°C to +105°C).
WV (V) : 160
D.F (%) : 15
WV (V)
:
200
15
250
15
350
20
400
20
200
3
6
400
5
__
450
20
Impedance : Z - 25°C / Z + 20°C
Impedance : Z - 40°C / Z + 20°C
Load Life : After apply rated voltage with rated ripple current for 2000hrs at 105°C the capacitors
shall meet the following reuirements.
(a) Capacitance Change : Within 20% of Initial Value
(b) Dissipation Factor : Not Exceed 200% of Initial Requirement
(c) Leakage Current : Not Exceed the Initial Requirement
Shelf Life : 1000 Hours, No Voltage Applied, at 105°C
(a) Capacitance Change : Within 20% of Initial Value
(b) Dissipation Factor : Not Exceed 200 % of Initial Requirement
(c) Leakage Current : Not Exceed 200% of Initial Requirement
Frequency(Hz)
120
500
1K
10K~100K
Temperature(°C)
Factor
65
2.10
85
1.70
105
1.00
DIAGRAM OF DIMENSIONS
Rubber Stand-off
4.0
5.0
Rubber End Seal
Dimensions : mm
F
1.5
2.0
2.5
3.5
5.0
0.45
0.5
Vinyl Sleeve
(P.V.C)
Rubber End Seal
Vinyl Sleeve
(P.V.C)
L
15Min.
5Min.
D 0.5
L
0.4Max.
15Min.
5Min.
D 0.5
6.0
8.0
10.0
12.0
13.0
16.0
18.0
22.0
F 0.5
F 0.5
0.6
7.5
10.0
0.8
0.8

Recommended Resources

How smart stores equipped with multiple sensors make shopping a breeze
It's a Friday evening and you decide to make fish tacos, so you pop into your local supermarket on your way home from get off work. It only takes a few minutes to find the cilantro, or, more accuratel...
alan000345 TI Technology Forum
[If you could choose again] If you could choose again, would you choose to continue working as an EE, or choose a state-owned enterprise that can provide you with retirement benefits?
1. I want to go to a retirement home, and I want to go to various retirement units, such as state-owned enterprises, civil servants, and public institutions near my home. 2. I still insist on my choic...
wb930129 Talking
ROHM R Classroom: Power supply design technical information is continuously updated. Click to download
Recently, Rohm's R Classroom was officially launched, focusing on power supply design technical information, including: basic knowledge, TECH INFO, design materials, product information, seminar infor...
EEWORLD社区 Power technology
Power Management
The power management feature allows the monitor to consume no more than 5 watts of power when it recognizes the yesa dpms (power management message) signal output from the vesa dprs video display card...
zbz0529 Power technology
TPS546D24_C23 dynamic voltage regulation
According to the PMBUS 1.3.1 version protocol, Section 2, Part 8.2, this article will briefly describe how to dynamically adjust the output voltage through VOUT_COMMAND. This method is applicable to a...
qwqwqw2088 Analogue and Mixed Signal
Sampling Theorem-------------What is the relationship between the detected signal and the ADC sampling rate?
Sampling Theorem-------------What is the relationship between the detected signal and the ADC sampling rate? Since the frequency of the electrical signal of the pelvic floor muscles is between 20Hz an...
QWE4562009 Test/Measurement

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号