EEWORLDEEWORLDEEWORLD

Part Number

Search

55.12.8.060.2061

Description
Electromechanical Relay, DPDT-CO, MBB, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.12.8.060.2061 Overview

Electromechanical Relay, DPDT-CO, MBB, AC/DC Output

55.12.8.060.2061 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompli
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)48 V
Coil resistance1200 Ω
Maximum coil voltage (AC)66 V
Nominal coil voltage60 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER CADMIUM OXIDE
Number of terminals8
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count8
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style2 FORM C
Relay functionDPDT-CO
release time5 ms
Terminal length0.0048 inch
Termination typeSOLDER
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
Technical Tutorial: Comparison of Linear and Switching Regulators for Automotive Applications
For years, the automotive demise of low-dropout linear regulators (LDOs) has been predicted. However, LDO regulators continue to survive and even thrive because they are inexpensive and easy to use. I...
frozenviolet Automotive Electronics
Please advise: What is the impact of wireless modules working in a wide voltage range?
The wireless IC data sheet says that the operating voltage range is 1.8V~3.7V. It is powered directly by dry batteries. The battery voltage changes greatly over time, but it is also within this range,...
pcf2000 RF/Wirelessly
EEWORLD University Hall----Live Replay: Microchip Security Series 17 - Pre-configured Wi-Fi? MCUs accelerate time to market and simplify production
Live Replay: Microchip Security Series 17 - Pre-configured Wi-Fi? MCUs accelerate time to market and simplify production : https://training.eeworld.com.cn/course/26653...
hi5 Integrated technical exchanges
A brief introduction to commonly used high-frequency electromagnetic field simulation software
Commonly used high-frequency electromagnetic field simulation software include the following: Ansoft HFSS, Designer, Emsenble. Ansoft has always used FEM (finite element method), and HFSS has an absol...
JasonYoo RF/Wirelessly
About Allegro copper plating
Is this how the guys who use Allegro lay out the copper skin? Lay a whole piece of copper sheet and buckle it to doubt life...
summer2019 PCB Design
MS430G2755 Code transplantation process for MSPBoot
1 Generation of MS430G2755 CMD fileFirst, use the Per tool to generate CMD files (Generating Linker Files). The Per tool will generate two CMD files, one for the MSP430G2755 Bootloader and the other f...
fish001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号