SMALL DIMENSION (ELECTRONIC) FUSES
1/4” x 1-1/4” Fast-Acting Fuses
AGC
Fast-Acting
1/4” x 1-1/4”
(6.3mm x 32mm)
Construction:
Glass Tube, Nickel-
plated brass endcaps.
Voltage Rating:
See Below
Interrupting Rating:
See Below
Agency Approvals:
UL Listed product meets standard 248-14
UL Listed Card: AGC 1/500-10
UL Recognition Card: AGC 11-30
CSA Component Acceptance Card
(Class No. 1422 30)
CSA Certification Card (Class No.
1422 01)
Electrical Characteristics
Current Rated
AC Interrupting
Rating Voltage
Rating
1
AC (Max.) 250V
125V
32V
1/20
250V
35V 10000A 1000A
1/16
250V
35V 10000A 1000A
1/10
250V
35V 10000A 1000A
1/8
250V
35V 10000A 1000A
3/16
250V
35V 10000A 1000A
2/10
250V
35V 10000A 1000A
1/4
250V
35V 10000A 1000A
3/10
250V
35V 10000A 1000A
3/8
250V
35V 10000A 1000A
45/100 250V
35V 10000A 1000A
1/2
250V
35V 10000A 1000A
3/4
250V
35V 10000A 1000A
1
250V
35V 10000A 1000A
1-1/4
250V
100A 10000A 1000A
1-1/2
250V
100A 10000A 1000A
2
250V
100A 10000A 1000A
2-1/4
125V
100A 10000A 1000A
2-1/2
125V
100A 10000A 1000A
3
125V
100A 10000A 1000A
4
125V
200A 10000A 1000A
5
125V
200A 10000A 1000A
6
125V
200A 10000A 1000A
7
125V
200A 10000A 1000A
8
125V
200A 10000A 1000A
9
125V
200A 10000A 1000A
10
125V
200A 10000A 1000A
15
32V
–
–
1000A
20
32V
–
–
1000A
25
32V
–
–
1000A
30
32V
–
–
1000A
1
Interrupting ratings were measured at 70% - 80% power factor on
AC, and at a time constant described in UL 198L.
ABC
Fast-Acting
Physical Size:
1/4” x 1-1/4”
(6.3mm x 32mm)
Construction:
Ceramic Tube
Voltage Rating:
See Below
Interrupting Rating:
See Below
Agency Approvals:
UL Listed product meets standard 248-14
UL Listed Guide & File numbers (ABC
1/4-15A): JDYX & E19180.
UL Recognition Guide & File numbers
(ABC 20-30A): JDYX2 & E19180.
CSA Certification Record No: 053787
C 000 & Class No: 1422 01 & 1422
30.
Electrical Characteristics
Current
Rated
Rating
Voltage
AC (Max.) DC (Max.)
1/4
250V
125V
1/2
250V
125V
3/4
250V
125V
1
250V
125V
1-1/2
250V
125V
2
250V
125V
2-1/2
250V
125V
3
250V
125V
4
250V
125V
5
250V
125V
6
250V
125V
7
250V
125V
8
250V
125V
10
250V
125V
12
250V
125V
15
250V
125V
20
250V
125V
25
125V
125V
30
125V
125V
AC Interrupting
Rating
1
250V 125V
35A 10000A
35A 10000A
35A 10000A
35A 10000A
100A 10000A
100A 10000A
100A 10000A
100A 10000A
200A 10000A
200A 10000A
200A 10000A
200A 10000A
200A 10000A
200A 10000A
200A 10000A
750A 10000A
400A 1000A
–
1000A
–
1000A
GBB
Very Fast-Acting
1/4” x 1-1/4”
(6.3mm x 32mm)
Construction:
Ceramic Tube
Voltage Rating:
See Below
Agency Approvals:
UL recognized product meets standard 248-
14
UL Recognized Card: GBB 1-30A (JFHR2,
E56412)
CSA Component Certified Card (Class
1422-01 File 53787)
Product Code & Voltage Rating
Product
Voltage
Code
Rating
AC
GBB-1
250V
GBB-1-1/4
250V
GBB-2
250V
GBB-3
250V
GBB-4
250V
GBB-5
250V
GBB-6
250V
GBB-7
250V
GBB-8
250V
GBB-9
250V
GBB-10
250V
GBB-12
250V
GBB-15
250V
GBB-20
250V
GBB-25
125V
GBB-30
125V
Physical Size:
Physical Size:
DC
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
NEW
EDISON
GBB
CROSS REFERENCE
OLD
EDISON BUSS
GOULD
—
GBB
None
LF
322
1
Interrupting ratings were measured at 70% - 80% power factor on
AC, and at a time constant described in UL 198L.
NEW
EDISON
ABC
CROSS REFERENCE
OLD
EDISON BUSS
GOULD
BBC
ABC
GAB
LF
314
NEW
EDISON
AGC
CROSS REFERENCE
OLD
EDISON BUSS
GOULD
BGC
AGC
GGC
LF
312
45