Product data sheet
Automation technology - sensors and actuators
Product description
Area
Order number
M12-A connecting cord for food and beverage industry, Contacts: 5, not shielded, moulded on cable, IP69K, M12x1, Standard
cable, PP grey, 5 x 0.34 mm²
M12-A series 763
77 3734 3727 40405-0500
Illustration
Scale drawing
Contact arrangement
Technical data
General values
Connector design
Connector locking system
Termination
Wire gauge (mm)
Wire gauge (AWG)
Upper limit temperature
Lower limit temperature
Customs tariff number
connecting cord for food and
beverage industry
screw
moulded on cable
0.34 mm²
22
105 °C
– 40 °C
85444290
Electrical values
Rated current (40 °C)
Rated voltage
Rated impulse voltage
Pollution degree
Overvoltage category
Insulating material group
Volume resistivity
Insulation resistance
EMC compliance
Degree of protection
Mechanical operation
2 A (0,14mm²), 4 A
60 V
1500 V
3
II
II
≤ 3 mΩ
≥ 10¹⁰ Ω
not shielded
IP69K
> 100 Mating cycles
Cable data
Cable length
Sheath material
Single-lead insulation
Single-lead structure
Cable diameter
Conductor resistance
Temperature range, moving cable, °C from
Temperature range, moving cable, °C to
Temperature range, fixed cable, °C from
Temperature range, fixed cable, °C to
Bending radius, fixed cable
Bending radius, moving cable
UL style 1
5m
PP
PVC
42 x 0,1
4.8 mm
57 Ω/Km
- 5 °C
105 °C
-40 °C
105 °C
≥5xØ
≥ 10 x Ø
AWM2517
Material
Contact material
Contact plating
Contact body material
Housing material
CuSn (bronze) / CuZn (brass)
Au (gold)
PP
PP
Date: 2019-06-03 - Page 1 of 2
Product data sheet
Automation technology - sensors and actuators
Product description
Area
Order number
M12-A connecting cord for food and beverage industry, Contacts: 5, not shielded, moulded on cable, IP69K, M12x1, Standard
cable, PP grey, 5 x 0.34 mm²
M12-A series 763
77 3734 3727 40405-0500
Security notices
The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible
for checking whether the connectors are suitable for use in other applications.
Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the
connectors must be separately protected against corrosion. For further information about IP degrees of protection
refer to ‘Technical support’ in the Download Centre.
To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’
(approx. 50 cNm).