FEATURES
Small Size
–
Safety Agency Approved
–
Metalized Polypropylene
EMI filters
–
Across the Line
APPLICATIONS
Operating Temperature Range
Capacitance Tolerance
AC voltage
(50/60 Hz)
Dissipation Factor
at 1 kHz and 20°C
(Not for use in Series with Mains; See MPXB)
-40°C to +110°C
+10% at 1 kHz, 20°C
UL/CSA
250/275/310
ENEC
250/275/310
Tan δ
.1% Max
Capacitance
Terminal to Terminal
15000 MΩ
Terminal to Case
>30000 MΩ at 100VDC
>5000 MΩ at 500VDC
>30000 MΩ at 100VDC
>0.33uF
5000 MΩxuF
>5000 MΩ at 500VDC
<1 nano-Henry per mm of lead spacing
1333VDC (4.3*310) VDC applied for 60 seconds
Terminal to Terminal
Cut-off current: 10mAdc
Current limiting resistance: 1Ω/V
2050VDC (50/60 Hz) applied between the terminals and case for 60
Terminal to case
Seconds and 20°C
1000 hours at 110°C at 125% of rated voltage with once every hour the voltage is
increased to 1000 VAC for 0.1 seconds
Capacitance change
<10% of initially measured value
Dissipation Factor
<0.8% at 1kHz
Insulation Resistance
>50% of initially specified value (T-T)
<0.33uF
Capacitance change
Dissipation Factor
Insulation Resistance
56 days at 90 to 95% RH, 40C
<10% of initially measured value
<0.8% at 1kHz
>50% of initially specified value (T-T)
C< 1uF Vp=2.5kVDC
C> 1uF Vp=2.5kV √C
-200ppm/°C, +100ppm/°C
Metallized Polypropylene film
Vacuum deposited Metal layers
Flame retardant Solvent resistant plastic case with epoxy end fill (UL94V-0)
tinned copper clad steel leads
CQC
310
Insulation Resistance
@20°C (<70% RH)for 1 minute
at 100VDC applied
Self Inductance
Dielectric Strength
Life Expectancy
Humidity test
Impulse voltage
(24 pulses)
Capacitance temperature
coefficient
Construction
Electrodes
Coating
Lead terminations
Nov-18
All Dimensions in (mm)
*17mm lead length available upon request
X capacitors are used to suppress electrical noise by reducing the input impedance of
the device incorporating the capacitor.
X capacitors are connected across the supply line where failure of the capacitor will
not result in personal exposure to electrical shock.
X2 capacitors are to be used in applications where the peak voltage is <1200V.
Safety
agency
Standard
ANSI/UL 60384-14
Voltage
250/275/310
Class
FOWX2
Certificate
number
E317135
UL/CSA
CSA E60384-1
250/275/310
FOWX8
E317135
VDE/ENEC
DIN EN 60384-14 (VDE 0565 (1-1),
EN60384-14:2013-08, IEC60384-14
(ED 4)
GB/T6346.14-2015 (.0022 to 10uF)
250/275/310
X2
40040758
CQC
310
X2
CQC14001115428
Nov-18