Surge Protection Circuit, ROHS COMPLIANT PACKAGE-2
CategoryWireless rf/communication    Telecom circuit   
File Size250KB,2 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2027-9B19LF Overview

Surge Protection Circuit, ROHS COMPLIANT PACKAGE-2

2027-9B19LF Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Parts packaging codeMODULE
package instruction,
Contacts2
Reach Compliance Codecompli
JESD-30 codeX-XXSS-X2
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeUNSPECIFIED
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal surfaceTIN
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
V E S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
8 mm diameter, 6 mm long
UL Recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* versions available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
2027 Series - 2-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Model No.
2027-20
200 V
Characteristic
DC Sparkover ±15 %
(±20 % for Models 2027-07 & 2027-09) @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±15 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2027-07
75 V
2027-09
90 V
2027-15
150 V
2027-23
230 V
2027-25
250 V
300 V
500 V
300 V
500 V
350 V
575 V
400 V
600 V
450 V
675 V
475 V
700 V
2027-30
300 V
550 V
800 V
2027-35
350 V
600 V
875 V
Model No.
2027-40
2027-42
400 V
420 V
650 V
925 V
675 V
950 V
2027-47
470 V
725 V
1000 V
2027-60
600 V
850 V
1100 V
Insulation Resistance .........................100 V (50 V for Models 2027-07 and 2027–09) ...................... > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................> 1A ........................................................................................ ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance .......................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage
**
.......................135 V, (52 V for Models 2027-07 and 2027-09,
80 V for Model 2027-15) ........................................................ < 150 ms
Impulse Discharge Current .................25000 A, 8/20 µs
***
................................................................. 1 operation minimum
10000 A, 8/20 µs .................................................................... > 10 operations
2500 A, 10/350 µs .................................................................. 2 operations
500 A, 10/1000 µs ................................................................. > 400 operations
100 A, 10/1000 µs or 10/700 µs ............................................. > 1000 operations
Alternating Discharge Current ............65 Arms, 11 cycles
***
.............................................................. 1 operation minimum
10 Arms, 1 s ........................................................................... > 10 operations
Operating Temperature....................................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1) ........................................................................................................ 40/90/21
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 27-xxxV.
• Sparkover limits ±20 % after life, IR >10
8
Ω
(-25 %, +30 % for Models 2027-07, 2027–09 and 2027–60).
• At delivery AQL 0.65 Level II, DIN ISO 2859.
**
Network applied.
***
DC Sparkover may
exceed ±20 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
How UWB calculates location
The application of UWB is also very clear. There are three main applications: imaging, communication and measurement, and vehicle-mounted radar systems. Looking at it from a macro perspective, the hig...
兰博 RF/Wirelessly
[Repost] When choosing a finished power module, should you use an isolated or non-isolated power solution?
When designing a power supply circuit for an embedded system or selecting a finished power supply module, one of the important issues to consider is whether to use an isolated or non-isolated power su...
皇华Ameya360 Power technology
Qorvo Q&A on Connectivity: Reducing Wi-Fi Interference
Q: What are the main concerns for customers regarding interference?For 2.4 GHz Wi-Fi, both interference and coexistence are very importantPrimarily because our mobile products emit many surrounding si...
Jacktang RF/Wirelessly
What device is used to heat the chip on the motherboard in low temperature outdoor conditions?
Has anyone had experience with this? When the device is taken outdoors in the north, the temperature of the motherboard may be lower than -20 degrees. Some components on the board are 0-70 degrees, wh...
yeahelton Discrete Device
CB5654 Development Board Evaluation 3 - Building a Development Environment
Following the step-by-step instructions in the documentation, I installed the CDK environment on Windows . There were no errors during the installation, but unfortunately I couldn't seem to connect to...
tobot Domestic Chip Exchange
Two-phase brushless DC motor speed control system based on DSP and CPLD
Rare earth permanent magnet brushless DC motor uses high-performance rare earth permanent magnet materials and non-contact commutation technology. It is small in size, high in efficiency, without elec...
Aguilera DSP and ARM Processors

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号