EEWORLDEEWORLDEEWORLD

Part Number

Search

X1550BLBB602AW

Description
Rocker Switch, DPST, Latched, Solder Terminal, Through Hole-straight, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size159KB,2 Pages
ManufacturerBULGIN
Websitehttp://www.bulgin.co.uk/
Environmental Compliance
Download Datasheet Parametric View All

X1550BLBB602AW Overview

Rocker Switch, DPST, Latched, Solder Terminal, Through Hole-straight, ROHS COMPLIANT

X1550BLBB602AW Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerBULGIN
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
body height16.2 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact voltage (AC)250 V
Manufacturer's serial number1550
Installation featuresTHROUGH HOLE-STRAIGHT
sealSPLASH PROOF
surface mountNO
Switch actionLATCHED
switch functionDPST
Switch typeROCKER SWITCH
Termination typeSOLDER
1550 Standard & 1350 High Inrush Switches
150A to EN61058-1 and 16A 250Vac
Standard rocker switch
1350/53 high inrush
Choice of switching
circuits including 3
position
Push-on, solder and
PCB terminals
Choice of bezel styles
Choice of panel cut outs
Matching indicator
Double pole
Splashproof option
Bezel size ‘A’ style
30.2 x 25.0
B
BLACK
R
RED
W
WHITE
In house test
In house test
1550 Series 16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp, 125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp, 125Vac 1/4hp.
UL 85˚C, file E45221, CSA file LR10990.
20A 28Vdc.
1350 series 16(4)A 250Vac T85 1E4 (10,000 Ops.)
On request 16(6)A 250Vac T125 5E4 (50,000 Ops.)
150A Inrush to EN61058-1.
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp.
UL 72Vdc 7A, 36Vdc 14A.
UL 85˚C, file E45221, CSA file LR10990.
20A 24Vdc
RoHS compliant
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 66 (indicators).
RoHS
NON-LIT
B
BLACK
R
RED
W
WHITE
A
C
G
R
LIT
AMBER
CLEAR
GREEN
RED
‘X’ ROCKER COLOR R,G,W,B
2
125V NEON
3
250V NEON
7
12V INCANDESCENT
C 1353 A L B R 2 602AW
ORDER FORMAT
TERMINAL
C
9.1
TERMINAL
CODE
FUNCTION
CODE
FUNCTION
ROCKER
CODE
BODY BODY
CODE COLOR
ROCKER
COLOR
LAMP VOLTAGE
OR “ON LIGHT”
ROCKER
A
Softline Matt
LEGEND &
OPTIONS
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
1
4
2
5
3
6
6.3 x 0.8
Standard
1550
1551
9.1
HP rating N/A
H
High Inrush
1350
Lit (not momentary)
ON - OFF
ON - OFF
(momentary ON)
ON - OFF
(momentary OFF)
Gloss only
Lit (not momentary)
W
Splashproof (with Arcshield)
P
Lit window Matt
Matt or gloss
B
Splashproof (with Arcshield)
V
Curved
1552
4.8 x 0.8*
HP rating N/A
K
9.1
2.0
1.2
1553
Not W, X or B rocker
1353
Not W, X or B rocker
ON - OFF
Lit
ON - ON
ON - ON
(momentary 1 side)
2 Circuit
ON - ON
ON - OFF - ON
ON - OFF - ON
(momentary 1 side)
ON - OFF - ON
(momentary 2 sides)
6
5
4
6
5
4
6
5
4
1560
µ
2.8 x 0.8*
1561
µ
HP rating N/A
Lit (not momentary)
T
1562
µ
7.0
Ø2.1
In house tests only
X
Two color Matt
1570
µ
Solder
125V & 250V 1/2 HP
H terminal rated T100 only
(ON OFF only - not momentary)
F
Flat lens Gloss (0480 only)
U
3.2
Ø2.1
1571
µ
HP rating N/A
H terminal rated T100 only
Top view
A
Softline lens Matt (0480 only)
as F but with raised profile
3
2
1
3
2
1
3
2
1
1572
µ
HP rating N/A
H terminal rated T100 only
Right angle T Solder (Not DP)
X
9.1
4.0
1484
µ
In-house tested to 10(3)A 250Vac
(B rocker only)
3 position selective
OFF - A - A+B
1487
µ
In-house tested to 10(3)A 250Vac
(B rocker only)
3 position selective
A - B - C (
link not supplied
)
3
Indicator
Technical data on page 66
6
5
4
6
5
4
6
5
4
R
Round
2
1
3
2
1
3
2
1
PCB 0.8Sq*
*Contact factory for details on 1350 series
0480
X terminal N/A
26
ARCOLECTRIC CORPORATION
31-315 Plantation Drive, Thousand Palms, CA 92276 Tel: 760-343-3650 Fax: 760-343-3651 email: info@arcolectric.com
Microstrip————Microstrip line
Microstrip What is Microstrip? The problem of wiring layout in low-frequency circuit boards emphasizes the concept of efficient space layout. This is because the impact on production cost is greatly a...
btty038 RF/Wirelessly
Can the master device send data to the slave device?
I am using bluetooth master module and CC2541 slave to connect. Can the master module send data to the slave module? If so, where is the TIperipheral routine that receives and processes the data? I ca...
chenbingjy Wireless Connectivity
MOSFET tube "fully saturated conduction"?
I often see people say that MOSFET is fully saturated and turned on. Can anyone provide a MOSFET that can be fully saturated and turned on? Thinking is completely stuck in BJT. Using BJT to understand...
PowerAnts Analog electronics
EEWORLD University -- Interview on Digi-Key and DFRobot's maker project
Digi-Key and DFRobot's maker project interview : https://training.eeworld.com.cn/course/4606...
hi5 Talking
[Sipeed LicheeRV 86 Panel Review] 4-Building the Compilation Environment
This article refers to the tutorial of the Allwinner Development Community: https://d1.docs.aw-ol.com/study/study_6helloword/ , and tries to run a hello word program on the board. Although the operati...
DDZZ669 Domestic Chip Exchange
DIY multifunctional STM32 mini remote control (with engineering files, can be used directly as a board)
I made a multifunctional STM32 mini remote control in my spare time during the holiday. Because the PCB company was having a promotion, I could get the board for 5 yuan! After receiving the board, I o...
bqgup Innovation Lab

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号