POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
IP117K
IP117AK
IP117HVK
IP117AHVK
IP317K
IP317AK
IP317HVK
IP317AHVK
/
/
/
/
/
/
/
/
LM117K
LM117AK
LM117HVK
LM117AHVK
LM317K
LM317AK
LM317HVK
LM317AHVK
FEATURES
•
•
•
•
•
1.5A Output Current Guaranteed
Internal Thermal Overload Protection
Output Short Circuit Protected
Hermetic Metal TO3 Package
Screening Options Available
APPLICATIONS
•
•
•
Adjustable Power Supplies
System Power Supplies
Precision Voltage / Current Regulators
DESCRIPTION
The 117/317 Series regulators are adjustable 3 terminal voltage regulators capable of supplying in excess of 1.5A over an output
voltage range of 1.25V to 40V (HV Series, 60V). The regulators are exceptionally easy to apply requiring only 2 external resistors
to set the output voltage.
Every effort has been made to make these devices easy to use and difficult to damage. Internal current limiting and power
limiting coupled with true thermal limiting prevents damage due to overloads or shorts, even if the regulators are not fastened
to a heat sink.
ABSOLUTE MAXIMUM RATINGS
(TC = 25°C unless otherwise stated)
VI - VO
IO
PD
TJ
Tstg
Input – Output Voltage Differential
Output Current
Power Dissipation
Operating Junction
Temperature Range
Storage Temperature Range
117 Series
317 Series
Standard
HV Series
40V
60V
Internally Limited
Internally Limited
-55 to +150°C
0 to +125°C
-65 to +150°C
THERMAL PROPERTIES
Symbols
R
θJC
Parameters
Thermal Resistance, Junction To Case
Min.
Typ.
Max.
3
Units
°C/W
** This datasheet supersedes document 2829
Semelab Limited reserves the right to change test conditions, parameter limits and package dimensions without notice.
Information furnished by Semelab is believed to be both accurate and reliable at the time of going to press. However
Semelab assumes no responsibility for any errors or omissions discovered in its use. Semelab encourages customers to
verify that datasheets are current before placing orders.
Semelab Limited
Coventry Road, Lutterworth, Leicestershire, LE17 4JB
Telephone +44 (0) 1455 556565
Fax +44 (0) 1455 552612
Email:
sales@semelab-tt.com
Document Number 8375
Issue 1
Page 1 of 7
Website:
http://www.semelab-tt.com
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
ELECTRICAL CHARACTERISTICS(1)(3)
(TC = 25°C unless otherwise stated)
LM117, IP117, LM117HV, IP117HV
Symbols
VREF
Parameters
Reference Voltage
Test Conditions
IOUT = 10mA
10mA
≤
IOUT
≤
IMAX, P
≤
PMAX,
3V
≤
(VIN-VOUT)
≤
VMAX
3V
≤
(VIN-VOUT)
≤
VMAX,
IOUT = 10mA
VOUT
≤
5V
Min.
1.200
Typ
1.250
1.250
0.010
Max.
1.300
Units
V
•
1.200
1.300
0.020
0.050
15
0.3
50
1.0
0.070
∆
V
OUT
∆
V
IN
Line Regulation (2)
•
%/V
mV
%
mV
%
%/W
dB
0.020
5
0.1
∆
VOUT
∆
IOUT
Load Regulation (2)(3)
10mA
≤
IOUT
≤
IMAX
VOUT
≥
5V
VOUT
≤
5V
VOUT
≥
5V
•
•
20
0.3
0.030
65
66
80
50
0.2
3.5
3.5
1.5
0.3
2.2
0.5
0.1
1.0
0.3
0.001
Thermal Regulation
Ripple Rejection
IADJ
Adjust Pin Current
Adjust Pin Current Change
VIN = 14.58V, IOUT = 1.5A,
PD = 20W, TA = 25°C, 20ms Pulse
VOUT = 10V
f = 120Hz
CADJ = 0
CADJ = 10µF
•
•
10mA
≤
IOUT
≤
IMAX,
2.5V
≤
(VIN-VOUT)
≤
VMAX
(VIN - VOUT)
=
40V
(VIN - VOUT)
=
60V (HV Series)
(VIN - VOUT)
≤
15V
100
µA
5
5
7
∆
IADJ
IMIN
•
•
•
•
•
•
•
Minimum Load Current
mA
ICL
Current Limit
(VIN - VOUT) = 40V
(VIN - VOUT) = 60V (HV Series)
A
∆
VOUT
∆
TEMP
∆
VOUT
∆
TIME
en
Temperature Stability
Long Term Stability
RMS Output Noise
(% of VOUT)
TA = 125°C, 1000Hrs
TA = 25°C, 10Hz
≤
f
≤
10KHz
1.0
%
Notes
The
●
denotes the specifications which apply over the full operating temperature range.
(1)
(2)
Test conditions unless otherwise stated: VIN - VOUT = 5V, IOUT = 0.5A, PMAX = 20W, IMAX = 1.5A
Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating
effects are covered under thermal regulation specifications. Load regulation is measured at
1
/
8
” below the bottom of the package.
VMAX = 40V for LM117, IP117, LM117A, IP117A, LM317, IP317, LM317A, IP317A
VMAX = 60V for LM117HV, IP117HV, LM117AHV, IP117AHV, LM317HV, IP317HV, LM317AHV, IP317AHV
(3)
Semelab Limited
Coventry Road, Lutterworth, Leicestershire, LE17 4JB
Telephone +44 (0) 1455 556565
Fax +44 (0) 1455 552612
Email:
sales@semelab-tt.com
Website:
http://www.semelab-tt.com
Document Number 8375
Issue 1
Page 2 of 7
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
ELECTRICAL CHARACTERISTICS(1)(3)
(TC = 25°C unless otherwise stated)
LM117A, IP117A, LM117AHV, IP117AHV
Symbols
VREF
Parameters
Reference Voltage
Test Conditions
IOUT = 10mA
10mA
≤
IOUT
≤
IMAX, P
≤
PMAX,
3V
≤
(VIN-VOUT)
≤
VMAX
3V
≤
(VIN-VOUT)
≤
VMAX,
IOUT = 10mA
VOUT
≤
5V
Min.
1.238
Typ
1.250
1.250
0.005
Max.
1.262
Units
V
●
1.225
1.270
0.010
0.020
15
0.3
50
1.0
0.020
mV
%
mV
%
%/W
%/V
∆
V
OUT
∆
V
IN
Line Regulation (2)
●
0.010
5
0.1
∆
VOUT
∆
IOUT
Load Regulation (2)(3)
10mA
≤
IOUT
≤
IMAX
VOUT
≥
5V
VOUT
≤
5V
VOUT
≥
5V
●
●
15
0.3
0.002
65
66
80
50
0.2
3.5
3.5
1.5
0.3
2.2
0.5
0.1
1.0
0.3
0.001
Thermal Regulation
VIN = 14.58V, IOUT = 1.5A,
PD = 20W, TA = 25°C, 20ms Pulse
VOUT = 10V
f = 120Hz
CADJ = 0
CADJ = 10µF
●
Ripple Rejection
IADJ
Adjust Pin Current
Adjust Pin Current Change
dB
100
µA
5
5
7
●
10mA
≤
IOUT
≤
IMAX,
2.5V
≤
(VIN-VOUT)
≤
VMAX
(VIN - VOUT)
=
40V
(VIN - VOUT)
=
60V (HV Series)
(VIN - VOUT)
≤
15V
∆
IADJ
IMIN
•
●
●
●
●
●
●
Minimum Load Current
mA
ICL
Current Limit
(VIN - VOUT) = 40V
(VIN - VOUT) = 60V (HV Series)
A
∆
VOUT
∆
TEMP
∆
VOUT
∆
TIME
en
Temperature Stability
Long Term Stability
RMS Output Noise
(% of VOUT)
TA = 125°C, 1000Hrs
TA = 25°C, 10Hz
≤
f
≤
10KHz
2
1.0
%
Notes
The
●
denotes the specifications which apply over the full operating temperature range.
(1)
(2)
Test conditions unless otherwise stated: VIN - VOUT = 5V, IOUT = 0.5A, PMAX = 20W, IMAX = 1.5A
Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating
effects are covered under thermal regulation specifications. Load regulation is measured at
1
/
8
” below the bottom of the package.
VMAX = 40V for LM117, IP117, LM117A, IP117A, LM317, IP317, LM317A, IP317A
VMAX = 60V for LM117HV, IP117HV, LM117AHV, IP117AHV, LM317HV, IP317HV, LM317AHV, IP317AHV
(3)
Semelab Limited
Coventry Road, Lutterworth, Leicestershire, LE17 4JB
Telephone +44 (0) 1455 556565
Fax +44 (0) 1455 552612
Email:
sales@semelab-tt.com
Website:
http://www.semelab-tt.com
Document Number 8375
Issue 1
Page 3 of 7
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
ELECTRICAL CHARACTERISTICS(1)(3)
(TC = 25°C unless otherwise stated)
LM317, IP317, LM317HV, IP317HV
Symbols
VREF
Parameters
Reference Voltage
Test Conditions
IOUT = 10mA
10mA
≤
IOUT
≤
IMAX, P
≤
PMAX,
3V
≤
(VIN-VOUT)
≤
VMAX
3V
≤
(VIN-VOUT)
≤
VMAX,
IOUT = 10mA
VOUT
≤
5V
Min.
1.200
Typ
1.250
1.250
0.010
Max.
1.300
Units
V
●
1.200
1.300
0.040
0.070
25
0.5
70
1.5
0.070
mV
%
mV
%
%/W
dB
100
µA
5
10
12
∆
V
OUT
∆
V
IN
Line Regulation (2)
%/V
●
0.020
5
0.1
∆
VOUT
∆
IOUT
Load Regulation (2)(3)
10mA
≤
IOUT
≤
IMAX
VOUT
≥
5V
VOUT
≤
5V
VOUT
≥
5V
●
●
20
0.3
0.030
65
66
80
50
0.2
3.5
3.5
1.5
0.15
2.2
0.4
0.1
1.0
0.3
0.003
Thermal Regulation
Ripple Rejection
IADJ
Adjust Pin Current
Adjust Pin Current Change
VIN = 14.58V, IOUT = 1.5A,
PD = 20W, TA = 25°C, 20ms Pulse
VOUT = 10V
f = 120Hz
CADJ = 0
CADJ = 10µF
●
●
10mA
≤
IOUT
≤
IMAX,
2.5V
≤
(VIN-VOUT)
≤
VMAX
(VIN - VOUT)
=
40V
(VIN - VOUT)
=
60V (HV Series)
(VIN - VOUT)
≤
15V
∆
IADJ
IMIN
•
●
●
●
●
●
●
Minimum Load Current
mA
ICL
Current Limit
(VIN - VOUT) = 40V
(VIN - VOUT) = 60V (HV Series)
A
∆
VOUT
∆
TEMP
∆
VOUT
∆
TIME
en
Temperature Stability
Long Term Stability
RMS Output Noise
(% of VOUT)
TA = 125°C, 1000Hrs
TA = 25°C, 10Hz
≤
f
≤
10KHz
1.0
%
Notes
The
●
denotes the specifications which apply over the full operating temperature range.
(1)
(2)
Test conditions unless otherwise stated: VIN - VOUT = 5V, IOUT = 0.5A, PMAX = 20W, IMAX = 1.5A
Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating
effects are covered under thermal regulation specifications. Load regulation is measured at
1
/
8
” below the bottom of the package.
VMAX = 40V for LM117, IP117, LM117A, IP117A, LM317, IP317, LM317A, IP317A
VMAX = 60V for LM117HV, IP117HV, LM117AHV, IP117AHV, LM317HV, IP317HV, LM317AHV, IP317AHV
(3)
Semelab Limited
Coventry Road, Lutterworth, Leicestershire, LE17 4JB
Telephone +44 (0) 1455 556565
Fax +44 (0) 1455 552612
Email:
sales@semelab-tt.com
Website:
http://www.semelab-tt.com
Document Number 8375
Issue 1
Page 4 of 7
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
ELECTRICAL CHARACTERISTICS(1)(3)
(TC = 25°C unless otherwise stated)
LM317A, IP317A, LM317AHV, IP317AHV
Symbols
VREF
Parameters
Reference Voltage
Test Conditions
IOUT = 10mA
10mA
≤
IOUT
≤
IMAX, P
≤
PMAX,
3V
≤
(VIN-VOUT)
≤
VMAX
3V
≤
(VIN-VOUT)
≤
VMAX,
IOUT = 10mA
VOUT
≤
5V
Min.
1.238
Typ
1.250
1.250
0.005
Max.
1.262
Units
V
●
1.225
1.270
0.010
0.020
25
0.5
50
1.0
0.020
mV
%
mV
%
%/W
%/V
∆
V
OUT
∆
V
IN
Line Regulation (2)
●
0.010
5
0.1
∆
VOUT
∆
IOUT
Load Regulation (2)(3)
10mA
≤
IOUT
≤
IMAX
VOUT
≥
5V
VOUT
≤
5V
VOUT
≥
5V
●
●
15
0.3
0.002
65
66
80
50
0.2
3.5
3.5
1.5
0.15
2.2
0.4
0.1
1.0
0.3
0.003
Thermal Regulation
VIN = 14.58V, IOUT = 1.5A,
PD = 20W, TA = 25°C, 20ms Pulse
VOUT = 10V
f = 120Hz
CADJ = 0
CADJ = 10µF
●
Ripple Rejection
IADJ
Adjust Pin Current
Adjust Pin Current Change
dB
100
µA
5
10
12
●
10mA
≤
IOUT
≤
IMAX,
2.5V
≤
(VIN-VOUT)
≤
VMAX
(VIN - VOUT)
=
40V
(VIN - VOUT)
=
60V (HV Series)
(VIN - VOUT)
≤
15V
∆
IADJ
IMIN
•
●
●
●
●
●
●
Minimum Load Current
mA
ICL
Current Limit
(VIN - VOUT) = 40V
(VIN - VOUT) = 60V (HV Series)
A
∆
VOUT
∆
TEMP
∆
VOUT
∆
TIME
en
Temperature Stability
Long Term Stability
RMS Output Noise
(% of VOUT)
TA = 125°C, 1000Hrs
TA = 25°C, 10Hz
≤
f
≤
10KHz
2
1.0
%
Notes
The
●
denotes the specifications which apply over the full operating temperature range.
(1)
(2)
Test conditions unless otherwise stated: VIN - VOUT = 5V, IOUT = 0.5A, PMAX = 20W, IMAX = 1.5A
Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating
effects are covered under thermal regulation specifications. Load regulation is measured at
1
/
8
” below the bottom of the package.
VMAX = 40V for LM117, IP117, LM117A, IP117A, LM317, IP317, LM317A, IP317A
VMAX = 60V for LM117HV, IP117HV, LM117AHV, IP117AHV, LM317HV, IP317HV, LM317AHV, IP317AHV
(3)
Semelab Limited
Coventry Road, Lutterworth, Leicestershire, LE17 4JB
Telephone +44 (0) 1455 556565
Fax +44 (0) 1455 552612
Email:
sales@semelab-tt.com
Website:
http://www.semelab-tt.com
Document Number 8375
Issue 1
Page 5 of 7