6
SERIES SOLID STATE RELAYS
F E AT U R E S
SOLID STATE CIRCUITRY
OPTICALLY COUPLED CIRCUIT
INTERNAL SNUBBER
C
US
B E N E F I T S
NO MOVING PARTS
ISOLATE INPUT FROM OUTPUT
PROTECTS RELAY FROM TRANSIENTS
VERIFY PRESENCE OF INPUT VOLTAGE
PROTECTION FROM ACCIDENTAL CONTACT
UL Recognized
File No. E52197
RED L. E. D. STATUS LAMP
CLEAR PLASTIC COVER
COMPLIES WITH REQUIREMENTS OF
*
IEC STANDARDS 947-4-1 AND
947-5-1 LOW VOLTAGE DIRECTIVE
MANUFACTURED
UNDER ISO 9002
*
IEC = INTERNATIONALCOMMISSION
ELECTROTECHNICAL
EVALUATION
*
CE TESTING ANDTHE UNDERWRITERS
PERFORMED BY
LABORATORIES AS A THIRD PARTY
PARTICIPANT
ALL CURRENT RATINGS ON THE FOLLOWING PAGES
ARE BASED ON USE OF A SUITABLE THERMALLY
CONDUCTIVE COMPOUND
(E.G. SILICONE GREASE BETWEEN THE SSR
MOUNTING BASE AND THE MOUNTING SURFACE
OF A SUITABLE HEAT SINK).
RED L. E. D.
STATUS LAMP
SAFETY COVER STANDARD
ON ALL MODELS EXCEPT
DUAL OUTPUT
FAMILY
ASX
DSX
DTX
DDX
INPUT-
CONTROL
AC
DC
DC
DC
OUTPUT-
LOAD
AC
AC
AC
DC
CONTROL-
METHOD
SCRs
SCRs
TRIAC
MOSFET
INPUT & OUTPUT
SCREW SIZE
UP TO 40 AMP
INPUT
M 3.5
ABOVE 40 AMP
M 3.5
M6
OUTPUT
M4
9/04
PHONE: ( 843 ) 393-5778
FAX: ( 843 ) 393-4123
EMAIL: info@magnecraft.com
2...
7
6
SERIES
SOLID STATE RELAYS
DTX - DC/AC
SPST & DPST, 10 TO 40 AMPS
C
US
WIRING DIAGRAM
(VIEWED FROM PIN END)
UL Recognized
File No. E52197
GENER AL SPECIFICATIONS (@ 25 ºC )
INPUT CHARACTERISTICS
Style:
Control Voltage Range:
Typical Input Current:
Must Release Voltage:
Maximum. Reverse Control Voltage:
OUTPUT CHARACTERISTICS
Style:
Load Voltage Range (50/60 Hz):
Rated Load Current:
Maximum Off-State Voltage dv/dt:
Minimum Load Current:
Non -Repetitive Surge Current (1 Cycle):
Maximum Off State Leakage current (Rms):
Typical On-State Voltage Drop (Rms):
Maximum I
2
T for Fusing (A
2
Sec):
Suggested Heatsink
ºC/W:
Maximum Turn - On Time:
Maximum Turn - Off Time:
MISCELLANEOUS CHARACTERISTICS
Dielectric Strength (Input/Output/Base):
Insulation Resistance:
Operating Temperature Range:
Storage Temperature Range:
Weight:
DTX
3 - 32 VDC
2 mA (62 series), 16 mA (64 series)
1 VDC
YES
INPUT
DTX - 3
40 Amp 10 Amp
250 uS 200 uS
50 mA
50 mA
100 A
250 A
10 mA
10 mA
1.6 VAC 1.6 VAC
35
438
3.2
1.4
W64
48 - 480 VAC
40 Amp
25 Amp
250 uS
250 uS
250 mA
20 mA
250 A
250 A
10 mA
10 mA
1.6 VAC
1.6 VAC
250
200
0.2
0.5
DIMENSIONS SHOWN IN INCHES & (MILLIMETERS)
.
W62
24 - 280 VAC
10 Amp
25 Amp
250 uS
250 uS
50 mA
120 mA
100 A
250 A
10 mA
10 mA
1.6 VAC
1.6 VAC
52
300
3.2
0.5
8.3 mS
8.3 mS
4000 V rms
100 megohms minimum @ 500 VDC
-40
ºC
to +80
ºC
-40
ºC
to +100
ºC
100 grams approx.
OUTLINE DIMENSIONS
2.250
(57.2)
1.87
(47.49)
4-
1
1
.750
(44.5)
6
OUTPUT
RE
L.E.
+3
INPUT
ORDERING CODE
6
CLASS:
LOAD VOLTAGE RANGE:
24 - 280 VAC:
CODE 2
48 - 480 VAC:
CODE 4
RATED LOAD CURRENT:
10 AMPS, 25 AMPS, 40 AMPS,
INPUT/OUTPUT STYLE:
DTX:
DC - INPUT / AC OUTPUT
2
10
DTX-
1
0.800 MAX. (20.32)
STANDARD
PART NUMBERS
*W6210DTX-1
*W6225DTX-1
*W6240DTX-1
*W6410DTX-1
*W6425DTX-1
*W6440DTX-1
W6210DTX-3
W6210DTX-4
*W6225DTX-4
W6240DTX-4
2
OUTPUT
INPUT 0.187 (4.74)
QUICK CONNECT
2 PLACES
RED L.E.D.
STATUS LAMP
-3 OPTION CODE
OUTPUT 0.250 (6.35)
QUICK CONNECT
4 PLACES
INPUT
RATED LOAD
CURRENT
10 AMPS
25 AMPS
40 AMPS
10 AMPS
25 AMPS
40 AMPS
10 AMPS
10 AMPS
25 AMPS
40 AMPS
9/04
OPTIONS:
-1 = ZERO CROSS, NORMALLY OPEN
-2 = RANDOM TURN ON, NORMALLY OPEN
-3 = DOUBLE POLE, RANDOM TURN ON, NORMALLY OPEN
-4 = RANDOM TURN ON, NORMALLY CLOSED
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
*
Approved
5
2...
11