SEPARABLE CONNECTORS STICK-OP WINDOW-OP
,
600 SERIES DEADBREAK
Elastimold’s 600 Series Window-Op~
and Stick-Op~ deadbreak connector
systems incorporate provisions for
hotstick operation of DE-ENERGIZED
primary feeder or network circuits.
The Window-Op and Stick-Op connec-
tors allow direct testing and grounding
with no required cable movement.
Window-Op is ideal for equipment
applications which include viewing
windows to provide an internal visible
break that does not require hot stick
removal of the elbows.
Stick-Op provides an external visible
break by hot stick removal of the elbow.
Window-Op and Stick-Op connectors
are bolted and installed using torque
controlled tools.
STICK-OPERABLE
BOLTED CONNECTION
LOADBREAK REDUCING
TAP PLUG
INSULATED
CAP
RATINGS OVERVIEW
See page 2 for complete information.
STICK-OP & WINDOW-OP SYSTEM – 600 SERIES DEADBREAK
SEE PAGE 26 FOR
SURGE ARRESTER
APPLICATIONS
STICK-OP
CURRENT RATINGS
600 & 900 Amp Continuous
25kA sym.,10 cycles
NOTE: 900 Amp ratings require copper cable
and copper current-carrying components.
CONTINUOUS
VOLTAGE RATINGS
15kV Class
8.3kV Phase-to-Ground
14.4kV Phase-to Phase
95kV BIL
34kV AC Withstand
53kV DC Withstand
11kV Corona Extinction
25kV Class
15.2kV Phase-to-Ground
26.3kV Phase-to Phase
125kV BIL
40kV AC Withstand
78kV DC Withstand
19kV Corona Extinction
35kV Class
21.1kV Phase-to-Ground
36.6kV Phase-to-Phase
150kV BIL
50kV AC Withstand
103kV DC Withstand
26kV Corona Extinction
INTEGRAL
BUSHING
600 SERIES
ELBOW
LOADBREAK
REDUCING
TAP PLUG
INSULATED CAP
WINDOW-OP
THREADED
COMPRESSION LUG
STICK-OP
OR
COMPRESSION LUG
WINDOW-OP
CABLE ADAPTER
SEE CABLE NOTES
TEST ROD
STAND-OFF
PLUG
ASSEMBLY TOOL
(WINDOW-OP)
ASSEMBLY TOOL
(STICK-OP)
GROUNDING
ELBOW
STICK-OP
600DB / 200LB
BUSHING/ELBOW
ADAPTER
GROUNDING
PLUG
OPERATING ACCESSORIES
ELASTIMOLD
CATALOG 2001 Page
16
ID: 0198
SEPARABLE CONNECTORS
DEADFRONT
LIVEFRONT
TERMINATIONS
SURGE ARRESTERS
600 SERIES DEADBREAK
35kV
FUSED ELBOWS
CABLE JOINTS
200 AMP LOADBREAK
200 AMP DEADBREAK
5-15kV
25kV
PART #
Part numbers that contain
the letters
W
or
X
are size
sensitive. To complete the
part number, refer to the
W
or
X
tables indicated.
STICK-OP™ & WINDOW-OP™
Illustration
(not to scale)
Description
WINDOW-OP
CONNECTOR
KIT
Voltage ELASTIMOLD
Class Part Number
15kV
25kV
35kV
STICK-OP
CONNECTOR
KIT
15kV
25kV
35kV
WINDOW-OP
Loadbreak
Reducing
Tap Plug
STICK-OP
Loadbreak
Reducing
Tap Plug
STICK-OP
Bushing
Adapter
Compression
Lug
WINDOW-OP
Threaded
Compression
Lug
STICK-OP
15kV
25kV
35kV
15kV
25kV
35kV
15kV
25kV
35kV
ALL
ALL
ALL
ALL
655ETP-W0X-DRG
Use Tables W7 and X6
Notes
N1,3,4,5,
6,13
K655ETP-W0X-DRG
Use Tables W7 and X6
755ETP-W0X-DRG
Use Tables W9 and X6
N1. Window-Op Kit includes: insulated cap; Window-Op reducing tap plug;
600 Series elbow housing; cable adapter; and 0370 style compression
lug.
N2. Stick-Op Kit includes insulated cap; Stick-Op Loadbreak reducing tap
plug; 600A Elbow Housing; cable adapter; and threaded 0360 style
compression lug.
N3. 600AT assembly tool required for operation and/or installation.
N4. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656; K675
for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756
and 2X for 0X in the part number. The 900 Amp rating requires copper
current-carrying connector components and copper conductor cable.
N5. Add suffix symbol from page 29 to include cable shield grounding kit
and/or cable jacket sealing kit.
N6. Aluminum lug for use on aluminum or copper conductors. DO NOT
substitute threaded 03600X lug.
N7. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT
substitute 03602X threaded lug.
N8. Threaded aluminum lug (Stick-Op only) for use on copper or aluminum
conductors. DO NOT substitute unthreaded 03700X lugs. DO NOT use
with 675, 676, K675, K676, 775 or 776 part numbers.
N9. Threaded copper lug (Stick-Op only) for use on copper conductors only.
DO NOT substitute unthreaded 03702X lugs.
655LRTP-W0X-DRG
Use Tables W7 and X6
N2,3,4,5,
8,13
K655LRTP-W0X-DRG
Use Tables W7 and X6
755LRTP-W0X-DRG
Use Tables W9 and X6
650ETP
K650ETP
750ETP
650LRTPA3
K650LRTPA2
750LRTPA2
650BEA3
K650BEA2
750BEA2
03700X
Use Tables X6
N4,15
N4,15
N4,15
N3,4
N3,4
N10. Required to disassemble Stick-Op loadbreak reducing tap plug from the
threaded compression lug and 600 Series elbow after the shear-pin is
broken during assembly.
N11. Stick-Op Operating Kit includes accessories that enable visible break
direct testing, isolation, and grounding functions to be performed. Kit
includes: 3-insulated parking bushings; 3-grounding elbows; 3-
600DB/200LB bushing/elbow adapters; 1-assembly tool; 1-test rod;
1-carry case; l-lubricant; 1-instructions.
N12. Window-Op Operating Kit includes accessories that enable visible
grounding and direct testing functions to be performed. Kit includes:
3-grounding elbows; 1-test rod; 1-carry case; 1-lubricant; 1-instructions.
N13. 600 Series Elbows and Straight Receptacles with IEEE Std. 386
capacitive test points are available by substituting 656 for 655; K656 for
K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776
for 775 in the part number.
N14. Rated for both 25kV and 35kV applications.
N15. 600ATM assembly tool required for Window-Op assembly.
N6
N7
N8
N9
N5
N5
N5
N5
N3,10
03702X
Use Tables X6
03600X
Use Tables X6
03602X
Use Tables X6
WINDOW-OP 15/25kV
Size Sensitive Kit
(Cable Adapter 35kV
& Lug)
STICK-OP
15/25kV
Size Sensitive Kit
(Cable Adapter 35kV
& Threaded Lug)
Extraction Tool
Grounding
Elbow
(1/0 AWG x 6'
Ground Lead)
Test Rod
Assembly Tool
(Stick-Op)
Assembly Tool
(Window-Op)
STICK-OP
OPERATING
KIT
WINDOW-OP
OPERATING
KIT
ALL
15kV
25kV
35kV
655CK-W0X
Use Tables W7 and X6
755CK-W0X
Use Tables W9 and X6
655TCK-W0X
Use Tables W7 and X6
755TCK-W0X
Use Tables W9 and X6
600ET
160GLR
370GLR
370GLR
N14
N14
ALL
ALL
ALL
15kV
25kV
35kV
15kV
25kV
35kV
370TR
600AT
600ATM
650STICK-OK
K650STICK-OK
750STICK-OK
650WINDOW-OK
K650WINDOW-OK
750WINDOW-OK
N3
N15
N11
N11
N11
N12
N12
N12
Refer to the
W
and
X
tables on pages 32 and 33 for sizing to cable
insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page 28.
CATALOG 2001 Page
17
ID: 0198