EEWORLDEEWORLDEEWORLD

Part Number

Search

FLU1-60-3AD

Description
OPEN-FRAME SWITCHING POWER SUPPLIES
File Size837KB,4 Pages
ManufacturerSLPOWER
Websitehttp://www.slpower.com/
Download Datasheet View All

FLU1-60-3AD Overview

OPEN-FRAME SWITCHING POWER SUPPLIES

50-60W
O
PEN
-F
RAME
S
WITCHING
P
OWER
S
UPPLIES
Single, Dual and Triple Output Models
Models with Universal AC Input or DC Input
CE
Mark: UL/CSA/EN60950 Approvals
Models to UL544/CSA C22.2-601/EN60-601
Medical Safety Standards
EN55022/FCC Class B Input Line Filters
0% Minimum Load Requirement
Over-Current/Short-Circuit Protection
2-Year Warranty
Minimum 200,000-Hour MTBF
C
HARACTERISTICS
Input Voltage ................................FLU and MDU models, universal input
voltage range 85-265 VAC single
phase or 100-370 VDC. DC-input mod-
els, see ratings table.
Input Line Frequency ...................47-440 Hz (ac input models).
Input Line Protection ....................FLU and MDU models, MOV transient
protected, input line fuse on-board.
(See Note 1.)
EMI Filter ......................................Standard (FLU and MDU models).
Performance surpasses conducted EMI
requirements of EN55022/FCC Class B
by 10 dB, typical.
Continuous Output Power ............FLU1-50, MDU1-50, FLU2-50, FLU3-
50, and DC50 series, 50W, max.
FLU1-60 and DC60 series, 60W, max.
Leakage Current...........................MDU series, non-patient contact rating:
300 µA, maximum.
Output Voltage Adjust...................Primary output adjustable ±5%.
Auxiliary outputs fixed.
Efficiency ......................................62-76%, typical (nominal input voltage,
nominal load conditions).
Hold-Up Time ...............................16 ms (115 VAC input), 32 ms (230
VAC input), minimum, at full load.
Overload Protection......................Power-limit circuit.
Short-Circuit Protection ................Continuous.
Over-Voltage Protection ...............FLU and MDU series, primary output
only (120% of rated output, typical).
Soft Start ......................................Standard on all ac-input models.
Design Topology...........................Flyback converter with current-mode
control.
Frequency of Operation ...............FLU1-50 and MDU1-50 series, 40 kHz,
fixed. DC50 and DC60 series, 100
kHz, fixed. FLU1-60, FLU2-50, FLU3-
50 series, 33 kHz, fixed.
Hi-Pot Isolation .............................FLU Series: 5300 VDC, input-to-output
for one minute.
MDU Series: 5700 VDC, input-to-output
for one minute.
DC50 and DC60 Series, 2500 VDC
input-to-output for one minute. (See
Note 2.)
Noise, Ripple and Spike...............FLU and MDU models, 1% peak-to-
peak, maximum. (See Notes 4, 5.)
Temperature Range......................-20°C to +70°C.
Output Power De-Rating ..............De-rate output power and current lin-
early 2%/°C from +50°C to +70°C.
Temperature Coefficient ...............±0.05%/°C over the entire operating
temperature range.
Relative Humidity .........................0 to 95%, non-condensing.
Altitude .........................................0 to 10,000 feet.
Cooling .........................................Convection cooling is adequate.
Moving air is recommended for opera-
tion in a confined area.
Storage Temperature....................-40°C to +85°C.
Storage Humidity..........................0 to 95%, non-condensing.
Mean Time Between Failures.......>200,000 hours. (Note 6.)
Model
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
Output (V)
(A) (A)
(A)
Tol. Reg. Reg. Reg.
AC-DC 50W Singles
FLU1-50-1AD
FLU1-50-2AD
FLU1-50-3AD
FLU1-50-4AD
FLU1-50-5AD
FLU1-50-6AD
V1
V1
V1
V1
V1
V1
5
9
12
15
24
28
0.00
0.00
0.00
0.00
0.00
0.00
10.0
5.60
4.20
3.33
2.10
1.75
10.0
5.60
4.20
3.33
2.10
1.75
85-265 VAC Input
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
AC-DC 50W Singles
To UL544/EN60-601/CSA 22.2-601.1
MDU1-50-1AD
MDU1-50-2AD
MDU1-50-3AD
MDU1-50-4AD
MDU1-50-5AD
MDU1-50-6AD
V1
V1
V1
V1
V1
V1
5
9
12
15
24
28
0.00
0.00
0.00
0.00
0.00
0.00
10.0
5.60
4.20
3.33
2.10
1.75
10.0
5.60
4.20
3.33
2.10
1.75
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
AC-DC 60W Singles
FLU1-60-1AD
FLU1-60-2AD
FLU1-60-3AD
FLU1-60-4AD
FLU1-60-5AD
FLU1-60-6AD
V1
V1
V1
V1
V1
V1
5
9
12
15
24
28
0.00
0.00
0.00
0.00
0.00
0.00
12.0
6.70
5.00
4.00
2.50
2.10
12.0
6.70
5.00
4.00
2.50
2.10
85-265 VAC Input
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
AC-DC 50W Duals
FLU2-50-1AD
FLU2-50-2AD
V1
V2
V1
V2
+5
+12
+5
+24
85-265 VAC Input
0.00 5.00 6.00 1.0% 0.2% 1.0% —
0.00 2.10 3.00* 5.0% 1.0% 3.0% 5.0%
0.00 5.00 6.00 1.0% 0.2% 1.0% —
0.00 1.10 1.50
5.0% 1.0% 3.0% 5.0%
* Peak output current rating = 5.0A (<60 seconds, duty cycle <10%).
† Peak output current rating = 2.5A (<60 seconds, duty cycle <10%).
Optional L-bracket enclosures for the FLU1-50
series are available. For details, see dimension
drawings for the Power General 40W series.
12
POWER GENERAL
152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号