2. *Diode type is available. (DC coil Plug-in type with LED indication only)
3. The LED indication color is green for the DC coil and red for the AC coil.
F
–1–
ASCTB114E 201709-T
HL
TYPES
1. Plug-in type
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-H-AC6V-F
HL1-H-AC12V-F
HL1-H-AC24V-F
HL1-H-AC48V-F
HL1-H-AC100V-F
HL1-H-AC120V-F
HL1-H-AC200V-F
HL1-H-AC240V-F
HL1-H-DC6V-F
HL1-H-DC12V-F
HL1-H-DC24V-F
HL1-H-DC48V-F
HL1-H-DC100V-F
2 Form C
Part No.
HL2-H-AC6V-F
HL2-H-AC12V-F
HL2-H-AC24V-F
HL2-H-AC48V-F
HL2-H-AC100V-F
HL2-H-AC120V-F
HL2-H-AC200V-F
HL2-H-AC240V-F
HL2-H-DC6V-F
HL2-H-DC12V-F
HL2-H-DC24V-F
HL2-H-DC48V-F
HL2-H-DC100V-F
To Be Discontinued
Last time buy: September 30, 2018
2. Plug-in type (with LED indication)
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-L-AC6V-F
HL1-L-AC12V-F
HL1-L-AC24V-F
HL1-L-AC48V-F
HL1-L-AC100V-F
HL1-L-AC120V-F
HL1-L-AC200V-F
HL1-L-AC240V-F
HL1-L-DC6V-F
HL1-L-DC12V-F
HL1-L-DC24V-F
HL1-L-DC48V-F
HL1-L-DC100V-F
2 Form C
Part No.
HL2-L-AC6V-F
HL2-L-AC12V-F
HL2-L-AC24V-F
HL2-L-AC48V-F
HL2-L-AC100V-F
HL2-L-AC120V-F
HL2-L-AC200V-F
HL2-L-AC240V-F
HL2-L-DC6V-F
HL2-L-DC12V-F
HL2-L-DC24V-F
HL2-L-DC48V-F
HL2-L-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3. Plug-in type (with LED indication and diode)
Nominal coil
voltage
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-L-DC6V-D-F
HL1-L-DC12V-D-F
HL1-L-DC24V-D-F
HL1-L-DC48V-D-F
HL1-L-DC100V-D-F
2 Form C
Part No.
HL2-L-DC6V-D-F
HL2-L-DC12V-D-F
HL2-L-DC24V-D-F
HL2-L-DC48V-D-F
HL2-L-DC100V-D-F
4. PC board type
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-HP-AC6V-F
HL1-HP-AC12V-F
HL1-HP-AC24V-F
HL1-HP-AC48V-F
HL1-HP-AC100V-F
HL1-HP-AC120V-F
HL1-HP-AC200V-F
HL1-HP-AC240V-F
HL1-HP-DC6V-F
HL1-HP-DC12V-F
HL1-HP-DC24V-F
HL1-HP-DC48V-F
HL1-HP-DC100V-F
2 Form C
Part No.
HL2-HP-AC6V-F
HL2-HP-AC12V-F
HL2-HP-AC24V-F
HL2-HP-AC48V-F
HL2-HP-AC100V-F
HL2-HP-AC120V-F
HL2-HP-AC200V-F
HL2-HP-AC240V-F
HL2-HP-DC6V-F
HL2-HP-DC12V-F
HL2-HP-DC24V-F
HL2-HP-DC48V-F
HL2-HP-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
5. PC board type (with LED indication)
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-PL-AC6V-F
HL1-PL-AC12V-F
HL1-PL-AC24V-F
HL1-PL-AC48V-F
HL1-PL-AC100V-F
HL1-PL-AC120V-F
HL1-PL-AC200V-F
HL1-PL-AC240V-F
HL1-PL-DC6V-F
HL1-PL-DC12V-F
HL1-PL-DC24V-F
HL1-PL-DC48V-F
HL1-PL-DC100V-F
2 Form C
Part No.
HL2-PL-AC6V-F
HL2-PL-AC12V-F
HL2-PL-AC24V-F
HL2-PL-AC48V-F
HL2-PL-AC100V-F
HL2-PL-AC120V-F
HL2-PL-AC200V-F
HL2-PL-AC240V-F
HL2-PL-DC6V-F
HL2-PL-DC12V-F
HL2-PL-DC24V-F
HL2-PL-DC48V-F
HL2-PL-DC100V-F
6. TM type
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-HTM-AC6V-F
HL1-HTM-AC12V-F
HL1-HTM-AC24V-F
HL1-HTM-AC48V-F
HL1-HTM-AC100V-F
HL1-HTM-AC120V-F
HL1-HTM-AC200V-F
HL1-HTM-AC240V-F
HL1-HTM-DC6V-F
HL1-HTM-DC12V-F
HL1-HTM-DC24V-F
HL1-HTM-DC48V-F
HL1-HTM-DC100V-F
2 Form C
Part No.
HL2-HTM-AC6V-F
HL2-HTM-AC12V-F
HL2-HTM-AC24V-F
HL2-HTM-AC48V-F
HL2-HTM-AC100V-F
HL2-HTM-AC120V-F
HL2-HTM-AC200V-F
HL2-HTM-AC240V-F
HL2-HTM-DC6V-F
HL2-HTM-DC12V-F
HL2-HTM-DC24V-F
HL2-HTM-DC48V-F
HL2-HTM-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
–2–
ASCTB114E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HL
RATING
1. Coil data
1) AC coils
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
Nominal coil current
(mA)
50Hz
60Hz
224
111
56
28
13.4/14.7
12.2/13.5
6.7/7.4
200
100
50
25
12/13.2
10.9/11.9
6/6.6
1.3
1.2
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
Nominal operating power
(VA)
50Hz
60Hz
Pick-up voltage
(at 20°C
68°F)
Drop-out voltage
(at 20°C
68°F)
Inductance (H)
When drop-out
0.078
0.312
1.243
4.974
23.75
27.19
85.98
When operating
0.074
0.295
1.181
4.145
20.63
25.57
81.76
110%V of
nominal voltage
Max. applied
voltage
(at 70°C
158°F)
Notes: 1. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
In particular, for AC operation, if the applied voltage drops to 80% V or more below the nominal voltage, humming will occur and a large current will flow leading
possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2) DC coils (at 20°C
68°F)
Nominal coil
voltage
6V DC
12V DC
24V DC
48V DC
100/110V DC
Nominal coil current
(mA)
150
75
37
18.5
10
1.0
Nominal operating
power (W)
Coil resistance
(Ω)
40
160
650
2,600
10,000
Pick-up voltage
(at 20°C
68°F)
80%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C
68°F)
10%V or more of
nominal voltage
(Initial)
Max. applied voltage
(at 70°C
158°F)
0.9
110%V of
nominal voltage
Notes: 1. The nominal operating current is
±10%
(20°C
68°F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C
68°F.
Compensate
±0.4%
for every
±1°C
change in temperature.
3. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
nominal voltage.
4. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
5. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Characteristics
Contact
Rating
Item
Contact resistance (Initial)
Contact material
Nominal switching capacity*
4
Min. switching capacity (Reference value)*
1
Insulation resistance (Initial)
Between open contacts
Between contact sets
Between contact and coil
Temperature rise (coil)
Breakdown voltage
(Initial)
Electrical
characteristics
Operate time (at 20°C
68°F)*
2
Release time (at 20°C
68°F)*
2
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Shock resistance
AC load
Electrical
DC load
Conditions for operation, transport and storage*
3
Max. Operating speed
Unit weight
Specifications
Max. 50 mΩ (By voltage drop 6 V DC 1A)
AgSnO
2
type
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)
2 Form C: 10A 250V AC (resistive load)
100mA 5V DC
Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
Max. 80°C
176°F
(By resistive method, nominal voltage)
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 196 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 2 mm
AC type: 5×10
7
(at 180 times/min.), DC type: 10
8
(at 180 times/min.)
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 5×10
5
2 Form C: 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 3×10
5
1 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×10
5
2 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×10
5
Ambient temperature: –50°C to +70°C
–58°F to +158°F
(Without LED indication);
–50°C to +60°C
–58°F to +140°F
(With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at max. rating)
Approx. 35g
1.23 oz
Mechanical
characteristics
Expected life
Conditions
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50°C to +40°C
–58°F to +104°F
(AC type).
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using the socket, be sure to verify the max. continuous current.
–3–
ASCTB114E 201709-T
HL
REFERENCE DATA
Switching capacity range (1 Form C)
15
10
AC resistive load
Contact current, A
10
AC inductive
load (cosϕ=0.4)
DC resistive
load
To Be Discontinued
Last time buy: September 30, 2018
Switching capacity range (2 Form C)
AC resistive load
Contact current, A
1 DC inductive
load (L/R=7ms)
AC inductive
load (cosϕ=0.4)
DC resistive
load
1 DC inductive
load (L/R=7ms)
0.1
10
100
500 1,000
0.1
10
100
500 1,000
Contact voltage, V
Contact voltage, V
With diode type (For DC)
1. DC coil surge voltage waveform
(without diode)
2. DC coil surge voltage waveform
(with diode)
Diode characteristics;
Reverse breakdown voltage: 1,000V,
Forward current: 1A
ON
OFF
ON
OFF
260V
+
+
12V DC
12V DC
To digital
memory
–
(
–
To digital
memory
Reverse breakdown voltage: 1,000 V
Forward current: 1 A
(
DIMENSIONS
(mm
inch)
1. Plug-in type
1 Form C
CAD Data
20.8
.819
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/