LIMIT SWITCH LEVER ARM T+FT, Rotary, 9007T/FT
Categoryunclassified   
File Size595KB,12 Pages
ManufacturerETC
Download Datasheet View All

9007TUA12 Overview

LIMIT SWITCH LEVER ARM T+FT, Rotary, 9007T/FT

Presentation, Application
Severe Duty Limit Switches
9007 Mill and Foundry Switches
Conforming to NEMA A600 and UL508
0
Description
9007T Mill Switches
Use the 9007T Mill switches instead of other limit switches in
the following applications:
1
Where the current load exceeds the typical heavy duty limit
switch contact rating of 10 A and falls within the range of
up to 20 A continuous.
2
Where an operating sequence is required that is not
possible on other limit switches. Fifteen sequences are
available. Universal type has twelve different operating
sequences with CW only, CCW only and neutral position.
Standard type has three operating sequences with CW
and CCW operation.
3
Where higher reset forces are required due to foreign
material interfering with lever arm operation, or where long
heavy arms must reset against gravity.
9007FT Foundry Switches
The 9007FT Foundry switches are for use in foundries or mills
where the applications described above are required, and
where falling foundry sand or similar material could build up
and jam the operating mechanism. The shaft has a dust boot
and extends from the switch case, preventing sand build up
around the shaft. The devices can withstand hot falling sand
up to 300° F (149° C.).
9007 (convertible sequence)
9007T Mill Switches
9007FT Foundry Switches
Pages 8 and 9
Pages 10 and 11
Application Information
Type T
— Ideal for applications requiring extra heavy duty contact ratings, or higher
operating and reset forces. Rugged mechanical construction with several different
operating sequences in one basic switch.
Type FT
— Designed specifically for rough foundry application. The shaft is entirely
beyond the switch case to prevent jamming of the lever arm due to build up of sand.
A dust boot is furnished as standard to further prevent sand packing and allow free
movement of the lever arm. An extra long shaft bearing makes the switch extremely
rugged and able to handle the rough applications encountered in foundries, mills,
machine tool and similar industries. The switch will withstand hot falling sand up to
300° F (149
°
C).
Type T and FT
Enclosure
— Oil-tight, dust-tight, water-tight, drip-tight meets NEMA 2, 4, and 13
requirements. Die cast zinc construction.
Operating Sequences
— Fifteen sequences available. Universal type has 12
different operating sequences with CW only, CCW only, and neutral position
operation. Standard type has three operating sequences with CW and CCW
operation. Various sequences will give quick make and break, spring return with
maintained contact, or slow make and break. Most sequences are convertible by
removing the base plate and adjusting the positioning plate and/or latches
Ambient Temperature Range
— 10° F (-12.2° C) to 185° F (85° C) ambient at full
rated load, up to 220° F (104° C) ambient with single coil load.
Lever Arm
— Die cast zinc construction with hardened, oil-impregnated, sintered
iron rollers.
Conduit
— 0.5" standard / 20 mm optional - Form M11
Mounting
— Four baseplates provide end or side mounting holes and/or manifold
mounting. All mounting holes are 0.25" (6.35 mm) diameter. Two tapped holes on
each side of switch allows side mounting.
Contacts
— SPDT, double break and three point double throw single break. Silver
contact tips. Phenolic contact block. Nylon liner. Polarity must be same on double
throw contacts.
Interpretation of Reference Numbers:
pages 31
6
Flying probe test to detect the electrical performance of PCB boards
Flying probe test: Use probes to replace the bed of nails, and use multiple motor-driven, fast-moving electrical probes to contact the pins of the device and perform electrical measurements.During the...
可乐zzZ PCB Design
Correct timing
Many analog circuits require a clock signal or require a task to be performed after a certain amount of time. For such applications, there are a variety of solutions available. For simple timing tasks...
qwqwqw2088 Analog electronics
How to use the crystal oscillator and capacitor in the TaunchPad G2 kit?
The crystal oscillator and capacitors in the TaunchPad G2 kit are used to build an external clock circuit. If they are directly soldered to the board without modifying the original jumpers on the boar...
alenc007 Microcontroller MCU
How to set the PCB wiring to 100 Ω uniform routing?
PCB wiring requires "wiring is 100 Ω", how should it be set at this time? How to calculate the impedance value of the wiring?...
shijizai PCB Design
Hello everyone, I made a microphone, and I need to use a preamplifier, I use MC2830D, the effect is average
The MC2830D used has average effect. If you have used it, you can chat with me....
泉州源达 Analog electronics
GD32L233C-START Review——05.SPI Test——Driving TFT Screen
[i=s]This post was last edited by wadeRen on 2022-2-17 22:32[/i] # GD32L233C-START Review——05.SPI Test—Driving TFT Screen# [Article Navigation] [GD32L233C-START Review——01.Unboxing, Development Kit](h...
wadeRen GD32 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号