SIOLSV2
Current Sensors
Features
Hall effect measuring principle
Galvanic isolation between primary and
secondary circuit
Low power consumption
Extended measuring range
Isolation voltage 3000V
I
PN
= 200…2000A,V
out
=±4V
Advantages
Easy installation
Small size and space saving
Only one design for wide current
ratings range
High immunity to external interference
Industrial applications
DC motor drives
Switched Mode Power Supplies(SMPS)
AC variable speed drives
Uninterruptible Power Supplies(UPS)
Battery supplied applications
Power supplies for welding application
Type
SIOLS200V2
SIOLS400V2
SIOLS600V2
SIOLS800V2
SIOLS1000V2
SIOLS2000V2
TYPES OF PRODUCTS
Primary nominal current
Primary current measuring range
r. m. s I
PN
(A)
I
P
(A)
200
400
600
800
1000
2000
±400
±800
±1200
±1600
±2000
±3000
General Description
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between
the primary circuit (high power) and the secondary circuit (electronic circuit)
1
V2.00 May 1, 2012
SIOLSV2
Current Sensors
Parameters Table
PARAMETERS
Supply voltage(±5%)
(1)
Current consumption
Output voltage
Isolation resistance
Output internal resistance
Load resistance
(2)
Linearity
(3)
(0…±I
PN
)
Accuracy
Electrical offset voltage
Hysteresis offset voltage
Temperature coefficient of V
OE
Temperature coefficient of
V
OUT
Response time
Frequency bandwidth
(4)
SYMBOL
V
C
I
C
V
out
R
IS
R
OUT
R
L
ε
L
X
G
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
BW
UNIT
Electrical data
V
mA
V
MΩ
Ω
KΩ
% of I
PN
% of I
PN
mV
mV
mV/K
%/K
μS
kHz
VALUE
±15
±15
±4
>1000
100
>10
<±1
<±1
<±20
<±10
<±1
<±0.1
<5
DC~25
@ 90% of I
PN
@-3dB
@ ± I
PN
, R
L
= 10 kΩ,
T
A
= 25°C
@ 500 VDC
CONDITIONS
Accuracy - Dynamic performance data
@ I
PN
, T
A
= 25°C
@ I
PN
, T
A
= 25°C
(excluding offset)
@T
A
= 25°C
@ I
P
= 0
Ambient operating temperature
Ambient storage temperature
Mass
Rated isolation voltage rms
Rms voltage for AC
isolation test
General data
T
A
°C
-40 ~ +85
T
S
°C
-40 ~ +105
m
g
300
Isolation characteristics
Vb
V
1000
Vd
kV
3
@50 Hz, 1 min
Notes:
1) Operating at
±12V
≤VC<±15V
will reduce the measuring range.
2) If the customer uses 10KΩ of the load resistor, the primary current has to be limited as the
nominal.
3) Linearity data exclude the electrical offset.
4) Please refer to derating curves in the technical file to avoid excessive core heating at high
frequency.
2
V2.00 May 1, 2012
SIOLSV2
Current Sensors
Dimensions SIOLSV2
(
in mm. 1 mm = 0.0394 inch
)
Instructions of use
1) When the test current passes through the sensors you can get the size of the output
voltage.(Warning: wrong connection may lead to sensors damage)
2) Based on user needs, the sensors output range can be appropriately regulated.
3) According to user needs, different rated input currents and output voltages of the sensors can be
customized.
3
V2.00 May 1, 2012
SIOLSV2
Current Sensors
RESTRICTIONS ON PRODUCT USE
The information contained herein is subject to change without notice.
SEC ELECTRONICS INC. (for short SEC) exerts the greatest possible effort to ensure high quality
and reliability. Nevertheless, semiconductor devices in general can malfunction or fail due to their
inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer,
when utilizing SEC products, to comply with the standards of safety in making a safe design for the
entire system, including redundancy, fire-prevention measures, and malfunction prevention, to prevent
any accidents, fires, or community damage that may ensue. In developing your designs, please ensure
that SEC products are used within specified operating ranges as set forth in the most recent SEC
products specifications.
The SEC products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic
appliances, etc.). These SEC products are neither intended nor warranted for usage in equipment that
requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause
loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy
control instruments, airplane or spaceship instruments, transportation instruments, traffic signal
instruments, combustion control instruments, medical instruments, all types of safety devices, etc..
Unintended Usage of SEC products listed in this document shall be made at the customer’s own risk.
4
V2.00 May 1, 2012