I1000RU
Series
Ultra-Miniature 10W
Wide 4:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
10W Output Power
•
4:1 Input Range
•
Ultra- Miniature Case
•
Remote On/Off Control
•
1,500 VDC Isolation
•
>350 kHour MTBF
•
Standard Pin-Out
Input
Parameter
Input Voltage Range
Start-Up Voltage
Under Voltage Shutdown
Input Filter
Conditions
Min.
Typ.
Max.
24 VDC Input
9.0
24.0
36.0
48 VDC Input 18.0
48.0
75.0
24 VDC Input
9.0
48 VDC Input
18.0
24 VDC Input
8.5
48 VDC Input
17.0
(Pi) Filter, Meets EN55022 Class A
Conditions
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 15% to 100%
Over Line, Load & Temperature
25% Load Step Change
300
±3.0
110
150
±0.01
Continuous (Autorecovery)
Min.
1,500
1,000
Typ.
Min.
Typ.
±1.0
±1.0
±0.3
±0.5
60
Max.
±2.0
±2.0
±1.0
±1.2
100
150
600
±6.0
±0.02
Units
VDC
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz), See Note 1
Transient Recovery Time, See Note 2
Transient Response Deviation
Output Power Protection
Temperature Coefficient
Output Short Circuit
Units
%
%
%
%
mV P - P
µSec
%
%
%/ºC
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Max.
Units
VDC
M
pF
kHz
Units
ºC
ºC
ºC
1,500
450
Min.
-40
Typ.
+25
Max.
+80
+100
+125
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Derating
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
-50
Free Air Convection
See Curve
RH, Non-condensing
95
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
1.00 x 1.00 x 0.40 Inches (25.4 x 25.4 x 10.16 mm)
Six-Sided Shielded Aluminum With Non-Conductive Base (UL94-V0)
0.52 Oz (15g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
350
Min.
-0.7
-0.7
Typ.
Max.
Units
kHours
Units
VDC
ºC
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Typ.
Max.
50.0
100.0
260
Caution:
Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
I1001RU
I1002RU
I1003RU
I1004RU
I1005RU
I1006RU
I1007RU
I1011RU
I1012RU
I1013RU
I1014RU
I1015RU
I1016RU
I1017RU
Voltage
(VDC)
Nominal
24
24
24
24
24
24
24
48
48
48
48
48
48
48
Range
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
Current
(mA)
Full-Load No-Load
352
496
483
474
496
477
474
180
248
241
237
248
238
237
30
30
30
30
30
30
30
20
20
20
20
20
20
20
Voltage
(VDC)
www.micropowerdirect.com
Output
Current
(mA, Max)
Current
(mA, Min)
Efficiency
(%, Typ)
Capacitive Fuse Rating
Load
Slow-Blow
(µF
Max)
(mA)
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
2,200
2,000
830
660
±1,000
±410
±330
2,200
2,000
830
660
±1,000
±410
±330
330
300
125
100
±150
±61
±50
330
300
125
100
±150
±61
±50
86
84
86
87
84
86
87
85
84
86
87
84
86
87
560
560
150
150
±220
±100
±100
560
560
150
150
±220
±100
±100
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
Notes:
1. Output ripple is measured with a 0.47 µF ceramic capcitor connected across the outputs.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
3. Operation at no-load will not damage the unit, but they may not
Min
Max
meet all specifications.
On
2.5 VDC 50 VDC
4. The On/Off Control input (Pin 3) is referenced to -Vin (Pin 2). If it is
not used, the control pin should be left open. If the pin is shorted to
Off
0.0 VDC 1.0 VDC
-V
IN
, the unit will turn off.
In. Current (on)
0.5 mA
6. It is recommended that a fuse be used on the input of a power
In. Current (off)
-0.5 mA
supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin
1
2
3
Single
Dual
Pin
4
5
6
Single
+Vout
No Pin
-Vout
Dual
+Vout
Common
-Vout
+Vin
+Vin
-Vin
-Vin
Remote ON/OFF
Mechanical Dimensions
Derating Curve
- Without HeatSink
Mechanical Dimensions
- With HeatSink
Derating Curve
- With HeatSink
Notes:
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.01 (
±
0.25)
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com