MPU-400E
Series
Single Output 400W
Power Factor Corrected
AC/DC Power Supplies
Key Features:
•
Small 400W Supply
•
PFC to EN 61000-3-2 “D”
•
EN 60950 Approved (UL)
•
CE Certified
•
FCC Class B Emissions
•
Universal AC Input
•
Compact Case w/End Fan
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current
Power Factor Correction
Input Protection
Conditions
Universal
Min.
90
47
Typ.
Max.
264
63
35
70
1.0
Units
VAC
Hz
A
A
mA
90 VAC
6
110 VAC
220 VAC
264 VAC
Meets EN 61000-3-2 Class D
T8A/250V Fuse
Conditions
By Trim Pot
Min.
Typ.
±5.0
±1.0
Output
Parameter
Output Voltage Adjustment
Output Regulation, See Note 1
Hold Time
Ripple & Noise (20 MHz), See Note 2
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time, See Note 4
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Max.
Units
%
%
mSec
%
ºC
%/ºC
mS
%
%
S
120 VAC, 80% Load
20
See Model Selection Guide
Foldback Circuit, Autorecovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
Autorecovery
+110
±0.04
2.5
50% Load Change
5
At Turn On/Off
±5.0
120 VAC
1
Continuous With Autorecovery
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
General
Parameter
Isolation Voltage, See Note 5
Switching Frequency
Units
VAC
23
kHz
Interface Signals
Power Supply On
Fan Fail
Power Good Signal
Green LED on the PCB
An open collector output rated for 15V/5 mA sink current maximum.
Goes high if a fan failure is detected
Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
before the loss of regulation. Will sink 100 mA.
A TTL low signal inhibits the output. Hiccup mode.
Conditions
Min.
Typ.
Max.
Units
0
+25
+70
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
Ambient
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Remote On/Off
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950, EN 60950
Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3
EN 6100-4-2,3,4,5,6,11; EN 55024; CE Marked (LVD)
Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s
2
on X, Y & Z Axis
www.micropowerdirect.com
Model Selection Guide
Model
Number
Output Voltage
(VDC)
PreSet
Range
10.0 - 13.8
21.0 - 26.0
43.0 - 50.0
Output
Current
(Max A)
www.micropowerdirect.com
Max.
Output
Power
(W)
Ripple
&
Efficiency
Noise
(%)
(% p-p)
MPU-400S-12
YE
12 VDC
MPU-400S-24
YE
24 VDC
MPU-400S-48
YE
48 VDC
33.33
16.67
8.33
400
400
400
±1%
±1%
±1%
85%
85%
85%
Model Number
Notes:
1. Output regulation includes line & load.
2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit is made
with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in
parallel.
3. A 1% minimum load is required to maintain regulation & ripple specifications.
4. Transient recovery is measured to within a 1% error band for a load step of 50%
to 100%.
5. Isolation specifications are production HI-Pot tested for 3 seconds.
6. The full output range (see table) is covered in the safety agency certification.
Standard models are factory set to the Preset voltage, but may be set to other
levels within the range without affecting the agency certification. For more
information, contact the factory.
7. Output power is given for the factory preset voltage. All models provide a peak
power level of 700W for a maximum duration of 500
µS.
For more information,
contact the factory.
8. Each unit includes an input fuse (T8A/250V). Since this fuse is not field replace-
able, it is recommended that an external fuse of the same size be used on the
input of the power supply for protection.
Mechanical Dimensions
Models with other output voltage levels
are available (i.e. 15 VDC, 36 VDC, etc)
Contact the factory for details at:
sales@micropowerdirect.com
Connections
I
nput/Output Connector (CN1):
•
Terminal Block:
Howder No. HB-95-7P
7 pins, M3.5 Screw, 9.5 mm Centers
•
JST Mating Part No:
VHR5N or equivalent (two pins removed)
VHR10N
Crimp Terminals: SVH41T-P1.1
Pin T Block
1
+V
OUT
2
+V
OUT
3
-V
OUT
4
-V
OUT
5 Field Grnd
6 AC-Neutral
7
AC-Line
Pin
1
2
3
4
5
6
7
8
9
10
1
3
5
JST
+V
OUT
+V
OUT
+V
OUT
+V
OUT
+V
OUT
-V
OUT
-V
OUT
-V
OUT
-V
OUT
-V
OUT
Field Grnd
AC-Neutral
AC-Line
Logic Signal Connector (CN2):
•
JST Mating Part No:
XHP-4 or equivalent
•
Mating Pins: JST SXH-002T-PO.6
For AWG 30 to 26
Pin
1
2
3
4
Function
Remote On/Off
Fan Fail
Common
Power Good
Fan Driver Connector (CN3):
•
JSTMating Part No:
JST XHP-2 or equivalent
•
Mating Pins: JST SXH-002T-PO.6
Pin
1
2
Function
Plus
Minus
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.02 (
±
0.50)
FAX: (781) 344-8481
•
TEL: (781) 344-8226
•
E-Mail: sales@micropowerdirect.com