EEWORLDEEWORLDEEWORLD

Part Number

Search

NH3AM50V630P-2

Description
Electric Fuse, 630A, 500VAC, 120000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size126KB,3 Pages
ManufacturerMersen
Websitehttps://www.mersen.com/

With over 135 years of experience, more than 50 industrial sites and 18 R&D centers in 35 countries, Mersen Electrical Power is a global expert in power and advanced materials for high-tech industries. They offer a broad portfolio of electrical protection and control products and provide solutions for power management applications. The Mersen team works with customers around the world to design and deliver custom solutions and essential products for the commercial, industrial, renewable energy, power electronics and electric vehicle markets. Mersen's mission is to make its customers' applications safer and more reliable.

Download Datasheet Parametric View All

NH3AM50V630P-2 Overview

Electric Fuse, 630A, 500VAC, 120000A (IR), Inline/holder,

NH3AM50V630P-2 Parametric

Parameter NameAttribute value
MakerMersen
Reach Compliance Codecompliant
ECCN codeEAR99
body width69 mm
body height61 mm
Body length or diameter76 mm
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
method of packingBULK
physical size76mm x 69mm x 61mm
Rated breaking capacity120000 A
Rated current630 A
Rated voltage (AC)500 V
GuidelineIEC; KEMA; OVE; SEV; VDE
surface mountNO
Terminal shapeTAB/BLADE

NH3AM50V630P-2 Preview

General Purpose IEC Fuses
General Purpose IEC Fuses
NH Fuses (Plain Blades)
aM Ceramic body with French striker
aM 690V Size 0 to 3
L216187
aM 500 - 690VAC
Size
Rated current Rated voltage
IN(A)
(V)
Previous ref.
Ref.-no.
Breaking
capacity
Catalog Number
P219272
Y212104
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
3
3
3
3
3
Pack. :
3 pieces
32
40
50
63
80
100
125
160
200
80
100
125
160
200
250
315
125
160
200
224
250
315
355
400
500
315
355
400
500
630
690V
690V
690V
690V
690V
690V
690V
690V
500V
690V
690V
690V
690V
690V
690V
500V
690V
690V
690V
690V
690V
690V
690V
690V
500V
690V
690V
690V
690V
500V
37443
37447
37451
37455
37459
37463
37465
37469
37471
37559
37563
37565
37569
37571
37575
37579
37665
37669
37671
37673
37675
37679
37681
37683
37687
37779
37781
37783
37787
37789
Z213140
R213639
V214148
Y214657
C215167
F215676
L216187
J216691
X217209
C217720
M218235
A218753
P219272
B222480
T223002
A200790
S201335
B201849
Y211069
P211590
Y212104
N212624
A213141
S213640
W214149
Z214658
D215168
G215677
M216188
K216692
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
120kA - 500V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
120kA - 500V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
120kA - 500V
80kA - 690V
80kA - 690V
80kA - 690V
80kA - 690V
120kA - 500V
NH0AM69V32P-2
NH0AM69V40P-2
NH0AM69V50P-2
NH0AM69V63P-2
NH0AM69V80P-2
NH0AM69V100P-2
NH0AM69V125P-2
NH0AM69V160P-2
NH0AM50V200P-2
NH1AM69V80P-2
NH1AM69V100P-2
NH1AM69V125P-2
NH1AM69V160P-2
NH1AM69V200P-2
NH1AM69V250P-2
NH1AM50V315P-2
NH2AM69V125-2
NH2AM69V160-2
NH2AM69V200-2
NH2AM69V224P-2
NH2AM69V250-2
NH2AM69V315P-2
NH2AM69V355-2
NH2AM69V400-2
NH2AM50V500-2
NH3AM69V315P-2
NH3AM69V355P-2
NH3AM69V400P-2
NH3AM69V500P-2
NH3AM50V630P-2
M216188
Dimensions
0
1
2
3
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
GPEU
40
124.5 134.5
66
67
39
40
49
55
14.5
16
15.5 15.5
14
14.5
15
20
6
6
14
14
10
10
59
65
60
61
3
3
41.5
45
47
52
150
67
56
62.5
19
15.5
14.5
26
6
15
10
72.5
61
3
-
60
150
67
69
76
24
15.5
14.5
32
6
16
10
86
61
3
-
60
General Purpose IEC Fuses
General Purpose IEC Fuses
NH Fuses (Plain Blades)
aM Ceramic body with French striker
aM 690V Size 0 to 3
aM 500 - 690VAC
MELTING TIME - CURRENT DATA – 32-630 AMPERES
TIME IN SECONDS
CURRENT IN AMPERES
PEAK LET-THRU CURRENT DATA – 32-630 AMPERES
MAXIMUM INSTANTANEOUS PEAK LET-THRU AMPERES
AVAILABLE CURRENT IN RMS SYMMETRICAL AMPERES
GPEU
41
General Purpose IEC Fuses
General Purpose IEC Fuses
NH Fuses (Plain Blades)
aM Ceramic body with French striker
aM 690V Size 0 to 3
aM 500 - 690VAC
Power Loss (Watts) at Rated Current
Rated current
IN(A)
Size
0
1
2
3
32
40
50
63
80
100
125
160
200
224
250
315
355
400
425
500
630
2.4 W
2.8 W
3.6 W
4.6 W
6.0 W
7.5 W
9.5 W
12.0 W
6.0 W
7.5 W
9.9 W
12.7 W
16.4 W
18.7 W
21.5 W
12.7
16.4
18.7
21.5
29.0
32.0
34.0
W
W
W
W
W
W
W
25.0 W
29.0 W
34.0 W
38.5 W
45.0 W
60.0 W
I
2
T CHARACTERISTICS – DISCRIMINATION
_ _ _ 660V
_ _ _ 500V
_ _ _ 380V
Operating I
2
t
_ _ _ Pre-arcing I
2
t
I
2
T (AMPERE
2
SECONDS)
FUSE-LINK RATED CURRENT IN (A)
GPEU
42
Sound Level Meter MASTECH MS6700 Disassembly Pictures and Information
Product informationDisassembly picture:Device Analysis:Data Sheet:...
littleshrimp Integrated technical exchanges
Design of Multi-channel Data Acquisition System Based on CPLD
[size=4] The data acquisition system has strong versatility and can be widely used in military, industrial production, scientific research and daily life. With the popularization of computers, the app...
Jacktang DSP and ARM Processors
EEWORLD University Hall----Underactuated Robotics MIT 2019 spring 6.382
Underactuated Robotics MIT 2019 spring 6.382:https://training.eeworld.com.cn/course/5371Robots today move far too conservatively, using control systems that attempt to maintain full control authority ...
老白菜 Integrated technical exchanges
Let's talk about what technologies we can use to help in the face of this pneumonia virus? ? ?
The Spring Festival is a time for family reunion and joy, but now we are worried about this virus crisis. I wish everyone well. As engineers, let's talk about what technologies can help from a technic...
okhxyyo Talking
EEWORLD University Hall----C2000 series new products bring convenience to servo and motor drive systems
The convenience brought by the new C2000 series products to servo and motor drive systems : https://training.eeworld.com.cn/course/5803...
hi5 MCU
Wireless positioning principle: TOA&AOA
TOA positioning method: TOA positioning method: It is mainly based on measuring the arrival time of the received signal between the base station and the mobile station, and then converting it into dis...
Jacktang Wireless Connectivity

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号