Off-line systems with auto-ranging or PFC front ends, industrial and process control,
distributed power, medical, ATE, communications, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V300C12T150BL2
300C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
V
OUT
P
OUT
2V
50W
3.3V
75W, 50W
5V
100W, 50W
8V
100W
12V
150W, 75W
15V
150W, 75W
24V
150W, 75W
28V
150W, 75W
36V
150W, 75W
48V
150W, 75W
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
2
= 2V
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
Finish
Pin Style
Tin/Lead
Blank:
Short
Tin/Lead
L:
Long
Gold
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Baseplate
Blank:
S
lotted
2:
Threaded
3:
Through-hole
300V Micro Family
Page 1 of 14
Rev 9.9
03/2017
vicorpower.com
800 927.9474
300V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
147.4
378.7
174.6
152.8
393.8
412.6
1.2
Min
180
Typ
300
Max
375
400
178.2
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
300V Micro Family
Page 2 of 14
Rev 9.9
03/2017
vicorpower.com
800 927.9474
300V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
300V Micro Family
Page 3 of 14
Rev 9.9
03/2017
vicorpower.com
800 927.9474
300V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
2V
OUT
, 50W (e.g. S300C2C50BL, V300C2C50BL)
Parameter
Efficiency
S300C2C50BL (enhanced efficiency)
V300C2C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
75.1
72.5
2.7
Typ
82.0
73.9
120
2.8
3.5
±0.02
28.8
28.8
Max
Unit
%
150
2.9
4.5
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
3.3V
OUT
, 75W (e.g. S300C3V3C75BL, V300C3V3C75BL)
Parameter
Efficiency
S300C3V3C75BL (enhanced efficiency)
V300C3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.0
80.0
4.14
Typ
85.0
81.2
120
4.3
3.4
±0.06
26.2
26.2
Max
Unit
%
150
4.46
5.1
±0.4
22.7
31.8
31.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.2
15.9
3.3V
OUT
, 50W (e.g. S300C3V3C50BL, V300C3V3C50BL)
Parameter
Efficiency
S300C3V3C50BL (enhanced efficiency)
V300C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.0
76.7
4.14
Typ
83.5
77.7
160
4.3
2.7
±0.02
17.5
17.5
Max
Unit
%
200
4.46
4
±0.2
15.15
20.6
20.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 100W (e.g. S300C5C100BL, V300C5C100BL)
Parameter
Efficiency
S300C5C100BL (enhanced efficiency)
V300C5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.2
82.0
6.03
Typ
86.0
83.2
105
6.25
4.4
±0.1
23
23
Max
Unit
%
132
6.47
6.6
±0.4
20
27
27
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
14
300V Micro Family
Page 4 of 14
Rev 9.9
03/2017
vicorpower.com
800 927.9474
300V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 50W (e.g. S300C5C50BL, V300C5C50BL)
Parameter
Efficiency
S300C5C50BL (enhanced efficiency)
V300C5C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.1
81.0
6.03
Typ
85.0
82.3
72
6.25
2.8
±0.02
11.5
11.5
Max
Unit
%
90
6.47
4
±0.2
10
13.5
13.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
7
8V
OUT
, 100W (e.g. S300C8C100BL, V300C8C100BL)
Parameter
Efficiency
S300C8C100BL (enhanced efficiency)
V300C8C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.6
82.5
9.36
Typ
86.0
83.7
220
9.7
3.8
±0.02
14.4
14.4
Max
Unit
%
275
10.1
4.4
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 150W (e.g. S300C12C150BL, V300C12C150BL)
Parameter
Efficiency
S300C12C150BL (enhanced efficiency)
V300C12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.4
85.5
13.7
Typ
88.0
86.6
170
14.3
5
±0.02
14.4
14.4
Max
Unit
%
213
14.9
7.5
±0.2
12.5
16.3
16.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 75W (e.g. S300C12C75BL, V300C12C75BL)
Parameter
Efficiency
S300C12C75BL (enhanced efficiency)
V300C12C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.2
85.0
13.7
Typ
88.0
86.4
200
14.3
4
±0.02
7.19
7.19
Max
Unit
%
250
14.9
5.3
±0.2
6.25
8.44
8.44
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Shaanxi Xi'an design unit recruits registered electrical power generation, transmission and transformation engineers
We are also recruiting registered first-class architects (full-time or part-time), ...
Python for S60, also known as PyS60 (Unix name), is Nokia's port of the general-purpose Python programming language to its S60 software platform, originally based on Python 2.2.2 of 2002. The latest f...
There are only two words that can describe my feelings: proud and moved.Share with everyone:Space station launch process:Space station development history:Tianhe core module:Robotic Arm:...
The problem is this, in order to manually set the input level state of some pins of the STM32F103 series microcontroller (statement: because a certain function is to be completed, it is randomly set b...
I have a Cadence 16.6 BRD file. After importing it using the AD13 version Import Wizard, it shows blank. I don’t know what’s going on. Can anyone help me convert it to a format that can be opened by D...
Series of articles:
【BLE 5.3 wireless MCU CH582】1. Getting to know the CH582 development board (unboxing)
【BLE 5.3 wireless MCU CH582】2. MounRiver IDE first experience
【BLE 5.3 wireless MCU CH582】3. N...