Series AM2Q-Z
2 Watt | DC-DC Converter
FEATURES:
•
•
•
•
RoHS Compliant
Wide 2:1 input range
High Efficiency up to 83%
Continuous short circuit
•
•
•
•
Operating Temperature -40ºC to 85ºC
Input / Output Isolation of 500VAC
No Tantalum capacitors used inside
Over voltage protection
Models
Dual output
Model
AM2Q-0512DZ
AM2Q-0515DZ
AM2Q-1212DZ
AM2Q-1215DZ
AM2Q-2412DZ
AM2Q-2415DZ
AM2Q-4812DZ
AM2Q-4815DZ
Input Voltage (V)
4.5-9
4.5-9
9-18
9-18
18-36
18-36
36-75
36-75
Output Voltage
(V)
±12
±15
±12
±15
±12
±15
±12
±15
Output Current
max (mA)
±65
±50
±65
±50
±65
±50
±65
±50
Isolation
(VAC)
500
500
500
500
500
500
500
500
Efficiency
(%)
82
81
83
83
81
82
80
79
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
No Load Input Current
Input reflected current
Nominal
5
12
24
48
Typical
4.5-9
9-18
18-36
36-75
LC Type
20
30
20
Maximum
4.5-9
9-18
18-36
36-75
Units
VDC
ms
mA
mA
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
3sec
Typical
50
500
Rated
500
Units
VAC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
Short Circuit protection
Short circuit restart
Line voltage regulation (Dual)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Minimum Load Current
25% load on one output –
100% load on the other output
Zener Diode Clamp
Conditions
Typical
±1
Maximum
Units
%
%
±5
±12
±15
Continuous
Auto Recovery
±0.5
±1
±0.02
50
0
±15
±18
V
LL-HL
Load:0-100% unbalanced
20MHz Bandwidth
% of Vin
%
%/
o
C
mV p-p
% of Max
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2Q-Z
2 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions
(L x W x H)
MTBF
Transient recovery deviation
Conditions
100% load
Derating above 60ºC
Typical
100
-40 to +85
-40 to +125
Maximum
Units
KHz
o
C
o
C
o
C
% RH
g
100
Free Air Convection
95
Nickel Coated Copper
10
1.08 x 0.70x 0.28 inches
27.50 x 18.00 x 7.00 mm
>1.6Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C )
±3
%
Safety Specifications
Parameters
Standards
Designed to meet IEC/EN 60950-1
Pin Out Specifications
Pin
1
2
3
4
5
500 VAC
Dual
-V Input
+V Input
+V Output
Common
-V Output
Dimensions
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2Q-Z
2 Watt | DC-DC Converter
Derating
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only