EEWORLDEEWORLDEEWORLD

Part Number

Search
 PDF

MWDM1L-67GP-0K2-18M1

Description
Interconnection Device
CategoryThe connector    Connector bracket   
File Size176KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

MWDM1L-67GP-0K2-18M1 Overview

Interconnection Device

MWDM1L-67GP-0K2-18M1 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerGlenair
Reach Compliance Codecompliant
ConnectorSide1MICRO-D
ConnectorSide2MICRO-D
Connector bracket typeWIRE AND CABLE
structureSOLID
DIN complianceNO
IEC complianceNO
length5.486 mm
MIL complianceNO
Number of conductors2
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
shieldNO
Wire gauge30 AWG
Wire and Cable NamesCABLE ASSEMBLY
Discussion on Current Detection Circuit in Switching Power Supply
Abstract: This paper introduces the implementation method of the current detection circuit, and discusses the problems of current transformer saturation and secondary current droop that are often enco...
zbz0529 Test/Measurement
I would like to ask about the problem of PWM control LED based on register configuration.
I just want to ask if I need to use the IO port to turn on the LED light after the PWM registers are configured?Or can I just use PWM to dim and brighten the LED, turn the light on and off?Why can I o...
一百年后的自己 51mcu
Design of Practical Low-Power Switching Voltage-Regulated Power Supply
Abstract: This paper introduces the design process of a practical low-power switching voltage-stabilized power supply. Its output voltage is highly stable, the source effect and load effect are small,...
zbz0529 Power technology
EEWORLD University Hall----Electromagnetic interference of power converters and related electromagnetic foundations
Power converter electromagnetic interference and related electromagnetic foundations : https://training.eeworld.com.cn/course/4590...
hi5 Power technology
Snapdragon 845 CPU
How to buy Xiaolong 845 CPU directly?...
2716261560 Buy&Sell
LIN communication, checksum error.
When communicating via LIN, the host sometimes displays a checksum error in response to the slave (DSP 28035). What could be the cause? Since the checksum is calculated by the 28035 LIN itself, how co...
喜鹊王子 TI Technology Forum

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号