CIT RELAY
™
FEATURES:
•
Switching capacity up to 10A
•
Small size and light weight
•
Low coil power consumption
•
High contact load
•
Strong resistance to shock and vibration
WJ105
18.2 x 10.6 x 14.7 mm
CONTACT DATA
Contact Arrangement
Contact Rating
1A = SPST N.O
1C = SPDT
5A @ 250VAC
10A @ 125VAC Resistive
¼ hp, 250VAC
TV-5, 120VAC
< 50 milliohms initial
AgCdO
150W 1250VA
277VAC, 30VDC
10A
Contact Resistance
Contact Material
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
COIL DATA
Coil Voltage
VDC
Coil Resistance
Ω ±
10%
Pick Up Voltage
VDC (max)
75%
of rated voltage
Release Voltage
VDC (min)
10%
of rated voltage
Coil Power
W
Operate Time
ms
Release Time
ms
Rated
Max.
3
3.9
2.25
0.3
5
6.5
3.75
0.5
6
7.8
4.50
0.6
.20
10
10
9
11.7
6.75
0.9
.45
12
15.6
9.00
1.2
24
31.2
18.00
2.4
48
62.4
36.00
4.8
CAUTION:
1. The use of any coil voltage less than the rated coil voltage may compromise the operation of the relay.
2. Pickup and release voltages are for test purposes only and are not to be used as design criteria.
.20W
45
125
180
400
720
2800
11520
.45W
20
55
80
180
320
1280
5120
GENERAL DATA
Electrical Life @ rated load
Mechanical Life
Insulation Resistance
Dielectric Strength, Coil to Contact
Contact to Contact
Shock Resistance
Vibration Resistance
Terminal (Copper Alloy) Strength
Operating Temperature
Storage Temperature
Solderability
Weight
100K cycles, typical
10M cycles, typical
100MΩ min @ 500VDC
300V rms min. @ sea level
750V rms min. @ sea level
100m/s
2
for 11ms
1.50mm double amplitude 10-40Hz
10N
-40
°C
to + 85
°C
-40
°C
to + 155
°C
230
°C ±
2
°C
for 10
±
0.5s
9.5g
CIT RELAY
Website:
www.citrelay.com
Tel: 763-535-2339
Fax: 763-535-2194