EEWORLDEEWORLDEEWORLD

Part Number

Search

RSB6RM05200114NN

Description
Barrier Strip Terminal Block, 20A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size146KB,4 Pages
ManufacturerThomas & Betts Corporation
Websitehttp://www.tnb.com/
Download Datasheet Parametric View All

RSB6RM05200114NN Overview

Barrier Strip Terminal Block, 20A, 1 Row(s), 1 Deck(s)

RSB6RM05200114NN Parametric

Parameter NameAttribute value
MakerThomas & Betts Corporation
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberRSB6
Installation typeBOARD
Number of layers1
Rows1
Number of channels5
Rated current20 A
Rated voltage300 V
safety certificateUL
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge14 AWG
Barrier Strips
Tri-Barriers
0.375" PITCH
SERIES RSB6
P
HYSICAL
P
ROPERTIES
H
OUSING
M
ATERIAL
:
Polypropylene
F
LAMMABILITY
:
UL94V-2
C
OLOR
:
Black
T
ERMINAL
T
ERMINALS
:
Brass, bright acid tin over copper plating
S
CREW
:
Steel w/Zinc + Chromate plating
C
LAMP
:
Steel w/Zinc + Chromate plating
RSB6RP##1102
Dimensions
M
ECHANICAL
P
ITCH
(T
ERMINAL
S
PACING
):
.375"
S
CREW
S
IZE
:
6-32
R
ECOMMENDED
PCB H
OLE
D
IA
.:
.062"
W
IRE
S
TRIP
L
ENGTH
:
.38"
R
ECOMMENDED
T
IGHTENING
T
ORQUE
:
9 in lbs.
R
ECOMMENDED
S
CREWDRIVERS
:
Stanley 1006-4,
Sears Craftsman 41581, Any #2 Phillips-Head
W
IRE
L
UG
W
IDTH
(M
AX
.):
8,1mm (.320")
CIRCUITS
(NOT
POSITIONS)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
C1
IN.
L1*
IN.
C2
IN.
.75
L2*
IN.
1.22
1.59
1.97
2.34
2.72
3.09
3.47
3.84
3.84
4.59
4.97
5.34
5.72
6.09
6.47
6.84
7.22
7.59
7.97
8.34
8.72
9.09
9.47
9.84
10.22
10.59
10.97
11.34
11.72
12.09
12.47
12.84
13.22
13.59
13.97
14.34
.37
.75
1.13
1.50
1.88
2.25
2.63
3.00
3.37
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
12.00
12.38
12.75
13.13
.84
1.22
1.59
1.97
2.34
2.72
3.09
3.47
3.84
4.22
4.59
4.97
5.34
5.72
6.09
6.47
6.84
7.22
7.59
7.97
8.34
8.72
9.09
9.47
9.84
10.22
10.59
10.97
11.34
11.72
12.09
12.47
12.84
13.22
13.59
1.13
1.50
1.88
2.25
2.63
3.00
3.37
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.75
9.75
10.13
10.50
10.88
11.25
11.63
12.00
12.38
12.75
13.13
13.50
13.88
E
LECTRICAL
P
ROPERTIES
M
AXIMUM
C
URRENT
:
20A
O
PERATING
V
OLTAGE
:
300V
W
IRE
R
ANGE
:
(Clamp Screw) #12 max AWG
(Binding Head Screw) #14 max AWG
D
IELECTRIC
W
ITHSTAND
:
3500V
E
NVIRONMENTAL
P
ROPERTIES
O
PERATING
T
EMPERATURE
R
ANGE
:-60ºC
to +105ºC
(-76ºF to +221ºF)
Recommended PCB Hole Pattern
34
35
36
C
OMPUTING
RSB B
LOCK
L
ENGTHS
.
D
IRECT
M
OUNTING
Use C1 & L1 for VP, SP, RP, HP mounting
options
E
ND
P
OSITION
M
OUNTING
Use L2 & C2 for VM, SM, RM, VE,
SE, RE mounting options
LR49571
E60980
Thomas & Betts Electronics/OEM Division Tel: 901-252-7766 Fax: 901-252-1312
Dimensions shown are for reference only. Dimensions are in inches.
74
Tsinghua University successfully developed a brain-computer interface system that can play football with the mind
College students play football with their minds Tsinghua University has successfully developed a "brain-computer interface" system that allows people to control external objects through their brains b...
soso RF/Wirelessly
Why Qorvo is leading the new era of Wi-Fi connectivity? You will know after reading this.
Distributed Wi-Fi, also known as Wi-Fi mesh, is the next generation of indoor infrastructure for the Internet of Things (IoT). It is based on a "Pod in Every Room" architecture that provides seamless ...
alan000345 RF/Wirelessly
Software defines IoT chips, and technology integration promotes LPWAN2.0 ubiquitous IoT (Part 1)
As one of the important infrastructures of the digital industry, the Internet of Things has ushered in a golden period of development. Through the collection, analysis and output of data, the Internet...
zeta联盟 RF/Wirelessly
About the power factor of switching power supply and its correction method
[i=s]This post was last edited by qwqwqw2088 on 2021-11-3 13:28[/i]Switching power supply power factor and its correction methodPower factor compensation: In the 1950s, a method was proposed to improv...
qwqwqw2088 Power technology
EEWORLD University ---- RFID Training Series
RFID training series : https://training.eeworld.com.cn/course/4965...
wanglan123 RF/Wirelessly
How to use jumper caps in circuits
Now I have a serial port [color=#ff0000](1)[/color] and want to use an external jumper cap to select which part to connect to [color=#ff0000](2)[/color] or [color=#ff0000](3)[/color]. How should I des...
xxhhzz PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号