Current Transformer Tester Introduction

Publisher:幸福之路Latest update time:2021-09-14 Source: eefocus Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

The current transformer on-site calibrator is simple to operate, with intuitive readings and rapid measurements. It can reduce power consumption and labor intensity. It is small in size and light in weight, easy to carry and test on-site. The current transformer calibrator can be tested at 5% of the rated working current (voltage). Reference standards: JJG313-94, JJG314-94.


In addition, the company is also required to produce current transformer calibrators for testing S-class current transformers and current transformer calibrators with a secondary voltage of 100/3V. At this time, the current transformer tester can measure the error of the current transformer at 1% of the rated working current; during the testing process, the instrument can conveniently perform self-calibration at any time to ensure the accuracy of the instrument; key components use imported components with stable and reliable quality, which are widely used in measurement, power supply and other departments and transformer manufacturers, and are ideal instruments for transformer testing.


product features:

1. The current transformer field calibrator adopts 320×240 dot matrix LCD, with a large visual range and long-life backlight, which is easy to use;

2. Full Chinese operation interface, beautiful interface;

3. The dial indicator, ratio difference and angle difference are displayed in extra large fonts to facilitate user observation;

4. Fully meet the requirements of JJG314-1993 and JJG314-1994, automatic sampling;

5. Automatically judge polarity error and ratio error;

6. The host computer software has the function of opening virtual instruments;

7. Completely solve the S-level measurement problem;

8. Automatically switch the measuring range;

9. The current transformer field calibrator adopts the perfect combination of advanced unique circuit and DSP technology, which completely solves the problem of instability of RC phase shift circuit.

10. Power consumption: < 15VA (without micro printer), < 25VA (with micro printer)

11. Harmonic suppression ratio: > 40db


Reference address:Current Transformer Tester Introduction

Previous article:High voltage cable testing equipment
Next article:Causes of cable fault tester failure

Latest Test Measurement Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号