MCC
Micro Commercial Components
TM
omponents
20736 Marilla Street Chatsworth
!"#
$
% !"#
PF351
THRU
PF355
35Amp Fast Recover
Rectifier
50 to 600 Volts
PRESSFIT
Features
•
•
•
•
•
Low Cost
Low Leakage
Low Forward Voltage Drop
High Current Capability
For Automotive Applications
Maximum Ratings
•
Standard polarity : Case is Cathode ; Lead is Anode
Note for positive terminal part number is as shown: PF351P
For negative terminal add an "N" to the suffix of the part
number . i.e. PF351N
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
•
•
F
MCC
Catalog
Number
Device
Marking
PF351
PF352
PF353
PF354
PF355
---
---
---
---
---
Maximum
Recurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
E
35V
70V
140V
280V
420V
50V
100V
200V
400V
600V
D
C
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
I
F(AV)
35A
T
A
= 125°C
Current
Peak Forward Surge
I
FSM
600A 8.3ms, half sine
Current
Maximum
1.0V
I
FM
= 35A;
Instantaneous
V
F
Forward Voltage
T
J
= 25°C*
Maximum DC
Reverse Current At
I
R
5
µA
T
J
= 25°C
Rated DC Blocking
500µA
T
J
= 100°C
Voltage
Typical Junction
C
J
100pF
Measured at
Capacitance
1.0MHz, V
R
=4.0V
*Pulse test: Pulse width 300
µsec,
Duty cycle 2%
A
B
DIMENSIONS
INCHES
MIN
¼
0.501
0.621
0.224
0.378
1.102
0.048
MM
MAX
0.505
0.629
0.232
0.390
-----
0.052
MIN
12.73
15.77
5.70
9.60
28.00
1.22
MAX
12.82
15.97
5.90
9.90
-----
1.32
NOTE
DIM
A
B
C
D
E
F
Revision: 6
www.mccsemi.com
2005/03/11
PF351 thru PF355
Figure 1
Typical Forward Characteristics
20
40
100
60
40
30
20
25°C
Amps
10
Amps
.6
.4
.2
.1
.06
.04
.02
.01
.4
.6
.8
Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
500
400
300
Amps
200
100
0
1.0
1.2
1.4
20
25
35
Figure 2
Forward Derating Curve
MCC
Micro Commercial Components
TM
15
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
50
75
100
125
150
175
°C
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
°C
Figure 4
Peak Forward Surge Current
600
1
2
4
6
8 10
Cycles
20
40
00
60 80 100
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Figure 3
Junction Capacitance
100
60
40
20
pF
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
1000
T
J
=25°C
Junction Capacitance - pF
versus
Reverse Voltage - Volts
Revision: 6
www.mccsemi.com
2005/03/11