ACLM-4619F
PIN DIODE FEEDBACK LIMITER
Frequency Range (min)
Peak Input Power (max)
CW Input Power (max)
CW Flat Leakage (max)
Insertion Loss (max)
VSWR (max)
2 – 18
100
2
13
2.4
2.2:1
GHz
W
W
dBm
dB
ratio
NOTES:
CW Leakage is measured at 1W input
Up to 1KW peak power handling is available. Insertion loss and VSWR will degrade slightly.
Power handling is linearly derated from full power at 25˚C to zero power at +150˚C.
ENVIRONMENTAL SPECIFICATIONS:
MIL-E-5400, MIL-STD-202, MIL-E-16400
Operating Temp: -55°C to +125°C
Storage Temp: -65°C to +150°C
Humidity: MIL-STD-202F, M103, Cond B
Shock: MIL-STD-202F, M213, Cond B
Altitude: MIL-STD-202F, M105, Cond B
Vibration : MIL-STD-202F, M204, Cond B
Thermal Shock: MIL-STD-202F, M107, Cond A
Temperature Cycle: MIL-STD-202F, M105C, Cond D
SCREENING:
Internal Visual per MIL-STD-883, Method 2017
Temperature Cycle: -65°C to +100°C, 10 cycles
OPTIONAL HIGH-REL SCREENING (Ref MIL-PRF-38534):
Stabilization Bake per MIL-STD-883, Method 1008
Temperature Cycle per MIL-STD-883, Method 1010
Constant Acceleration per MIL-STD-883, Method 2001
Burn-in per MIL-STD-883, Method 1015
Leak Test per MIL-STD-883, Method 1014
External Visual per MIL-STD-883, Method 2009
STANDARD CASE STYLE C36
(Optional Case Styles – C37, M22)
PART NUMBER ORDERING INFORMATION:
•
•
•
•
Add desired case style suffix: “C36” (Ex: ACLM-4619FC36)
Add “R” suffix: Reverse Connector Configuration (Ex: ACLM-4619FC36R) (SMA Female Input/SMA Male Output)
Add “1K” suffix: High power handling version: (Ex: ACLM-4619FC36R1K)
Add “-RC” suffix: RoHS-compliant (Ex: ACLM-4619FC36R1K-RC)
0109
611 Industrial Way West, Eatontown, NJ 07724
tel: 732-460-0212 fax: 732-460-0214
sales@advanced-control.com
www.advanced-control.com