EEWORLDEEWORLDEEWORLD

Part Number

Search

56.34.8.120.0378

Description
Electromechanical Relay, 4PDT, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.34.8.120.0378 Overview

Electromechanical Relay, 4PDT, AC/DC Output

56.34.8.120.0378 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width27.7 mm
body height37.1 mm
Body length or diameter40.8 mm
Coil operating voltage (AC)96 V
Coil resistance2560 Ω
Maximum coil voltage (AC)132 V
Nominal coil voltage120 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Nickel
Number of terminals14
operating hours10 ms
physical size40.8mm x 27.7mm x 37.1mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay function4PDT
release time4 ms
Terminal length0.007 inch
Termination typeQUICK CONNECT
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
Can you help me design a washing machine controller? It's paid. If you want, please contact me, QQ: 993849120
Use proteus simulation and 51 single chip microcomputer, the requirements are as follows:⑴The controller has the functions of normal operation, cycle test and quick test. ⑵Normal working includes: wat...
北荒的你 MCU
1. GD32L233C-START (unboxing), turn on the lights as usual.
Thanks to EEWORLD and GD32 official for giving me the opportunity to evaluate GD32L233. I received the board two days ago. Today is the beginning of my holiday, and I finally have time to take it out ...
wm20031015 GD32 MCU
Shanghai Hangxin ACM32F070 Development Board + Touch Function Evaluation Board - Part 4 HRNG Module and Random Number Generation Time Measurement
[i=s]This post was last edited by oxygen_sh on 2022-10-26 22:54[/i]This evaluation experiment uses the TRNG module to generate 256-bit random numbers and measures the random number generation time. Ac...
oxygen_sh Domestic Chip Exchange
What are the advantages of PHY6212 that can support Bluetooth Mesh networking (Part 2)
ROM PHY6212 has 2 ROMs in total.SRAMThe SRAM of PHY6212 is divided into 5 blocks, each of which has individually configurable data retention capabilities, and all blocks can be used to store programs ...
乐乐熊 Integrated technical exchanges
For low-power products, after entering the sleep state WFI, the standard power consumption is 10uA, and the current power consumption is 50uA. Where might the 40uA come from?
A low-power product designed for STM32 MCU, after entering the sleep state WFI, the standard power consumption is 10uA, and the current power consumption is 50uA. Which component or port setting may c...
一沙一世 stm32/stm8
What are the future development directions of the new generation of Internet of Things?
What are the future development directions of the new generation of Internet of Things? In a recent article , Qorvo shared that the main development directions of the new generation of Internet of Thi...
alan000345 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号