OWT SERIES - TRIPLE OUTPUT, 25 WATT
DESCRIPTION
OWT triple output DC/DC converters provide up to
25 Watts of output power in an industry standard 2” x 2”
package. OWT units feature excellent efficiency, five-
sided shielding, and fixed switching frequency. With
85°C case operation, the OWT is especially suited to
telecom, networking, and industrial applications.
FEATURES
• Industry Standard
Package
• 12V Input
• 25W Output
•
•
•
•
External Enable Pin
5-Sided Shielding
500V Isolation
85°C Case Operation
Efficiency vs. Load (24V Input)
85
80
75
EFFICIENCY %
70
65
60
OWT2405-12
OWT2405-15
TECHNICAL SPECIFICATIONS
Input
Voltage Range
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
Input Ripple Current
Reverse Input Current
10 - 20 VDC
18 - 36 VDC
20 - 60 (add -S1 to p/n) or 36 - 72 VDC
20% Iin Max.
100% Iin Max.
Output
EFFICIENCY %
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
Efficiency vs. Load (48V Input)
85
80
75
Setpoint Accuracy, V
out1
/ V
out2
/ V
out3
Line regulation V
in
Min. - V
in
Max., I
out
Rated
±1%, ±5%, ± 5%
±1% V
out
±1%, ±5%, ± 5%
25 %
25% I
out
4% V
out
500
µs
±10%
Continuous
130%
70
OWT4805-12
65
OWT4805-15
60
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
Load regulation I
out
Min.- I
out
Max., V
in
Nom., V
out1
/ V
out2
/ V
out3
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of I
out
Rated
General
Remote Shutdown
Remote Shutdown Reference
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF
†
(Bellcore TR-NWT-000332)
Safety
Positive
V
in
Negative
300 kHz
500 VDC
500 VDC
500 VDC
0.02%/°C
-25 to +60°C1
-40 to +125°C
95%
5 g, 10 -55 Hz
1.8 x 106 hrs
UL 1950, CSA 22.2-950, EN60950
Notes
1 Industrial temp range of -40 to +85C available, add suffix -I to P/N
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Rev. SEP 17, 2002
1
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer
and add them to the model number. Example ordering options are located below the options table.
OPTION
Negative Logic
Lucent-Compatible Trim
Terminal Strip
Trim
Enable
Trim and Enable
SUFFIX
N
T
TS
1
2
3
APPLICABLE SERIES
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
XWS, XWD, XWT
IAS, LES
IAD, IAS, LES, SMS
IAS, LES
REMARKS
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Pin Length and Heatsink Options
0.110" (2.8mm) Pin Length
0.150" (3.8mm) Pin Length
0.24" (6.1mm) Horizontal Heatsink
0.24" (6.1mm) Vertical Heatsink
0.45" (11.4mm) Horizontal Heatsink
0.45" (11.4mm) Vertical Heatsink
0.95" (24.1mm) Horizontal Heatsink
0.95" (24.1mm) Vertical Heatsink
8
9
1H
1V
2H
2V
3H
3V
All Leaded Models
All Leaded Models
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Standard Pin Length is 0.180" (4.6mm)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional President
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
REV. AUG 16, 2002
3