EEWORLDEEWORLDEEWORLD

Part Number

Search

LS1001-7EPD0TB2

Description
AC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
CategoryPower/power management    The power supply circuit   
File Size439KB,33 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LS1001-7EPD0TB2 Overview

AC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE

LS1001-7EPD0TB2 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE S02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage264 V
Minimum input voltage85 V
JESD-30 codeR-MXMA-X
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage5.13 V
Minimum output voltage5.07 V
Nominal output voltage5.1 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output100 W
Fine-tuning/adjustable outputNO
S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
Features
Input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47-440 Hz
1or 2 isolated outputs up to 48 VDC
Class I equipment
RoHS lead solder exemption compliant
Extremely-wide input voltage range
Input over- and undervoltage lockout
Efficient input filter and built-in surge and transient
suppression circuitry
Outputs: SELV, no-load, and short-circuit proof
No derating over entire operating temperature range
111
4.4"
3U
60
2.4"
12 TE
168
6.6"
PCBs coated with protective lacquer
Very high reliability
Safety according to IEC/EN 60950
Description
The S Series AC-DC and DC-DC converters represents a broad
and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LS models can be powered by
DC or AC with a wide-input frequency range (without PFC).
The converter inputs are protected against surges and
transients. An input over- and undervoltage lockout circuitry
disables the outputs if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-on.
All outputs are open- and short-circuit proof and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to pin 18
(i). If the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.
Full input-to-output, input-to-case, output-to-case and output-to-
output isolation is provided. The converters are designed and
built according to the international safety standards IEC/EN
60950 and EN50155. They have been approved by the safety
agencies TÜV and UL (for USA and Canada).
The case design allows operation at nominal load up to 71 °C in a
free-air ambient temperature. If forced cooling is provided, the
ambient temperature may exceed 71 °C, but the case temperature
must remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which disables
the outputs if the case temperature
Tc
exceeds the limit. The
outputs are automatically re-enabled when the temperature drops
below the limit.
Various options are available to adapt the converters to individual
applications.
The converters may either be plugged into a 19" rack system
according to IEC 60297-3, or be chassis mounted. They are ideally
suited for Railway applications.
Important:
For applications requiring compliance with IEC/EN
61000-3-2 (harmonic distortion), please use our LS4000 and LS5000
Series with incorporated power factor correction (PFC).
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ....................................15
Immunity to Environmental Conditions ..................................17
Mechanical Data ....................................................................18
Safety and Installation Instructions ........................................19
Description of Options ............................................................23
Accessories ............................................................................32
EC-Declaration of Conformity ................................................33
Description ................................................................................1
Model Selection ........................................................................2
Part Number Description and Product Marking ........................3
Functional Description ..............................................................4
Electrical Input Data ..................................................................5
Electrical Output Data ..............................................................8
Auxiliary Functions ..................................................................12
APR 26, 2006 revised to SEP 25, 2006
Page 1 of 33
www.power-one.com
After connecting to UPS, some devices do not work
I have a UPS at home. I just replaced the battery and plan to use it with a fish tank for uninterrupted oxygen supply. Everything is normal when connected to the mains, but when the UPS is powered, th...
hn200918 Analogue and Mixed Signal
Free evaluation - Topmicro intelligent display module (7) practical application
[i=s]This post was last edited by wenyangzeng on 2021-11-8 15:08[/i]Free evaluation - Topmicro intelligent display module (7) practical applicationAs an evaluation of actual application, STM8S105S4-PK...
wenyangzeng Test/Measurement
22 "Wanli" Raspberry Pi car - mobile phone remote control motor rotation
[i=s]This post was last edited by lb8820265 on 2022-1-30 11:55[/i]After struggling for a long time on how to accurately control the wheel speed, I finally decided to use open-loop control without cali...
lb8820265 Innovation Lab
[Raspberry Pi 4B Review] Install Libreelec system on Raspberry Pi 4 and install plug-ins to watch IPTV live broadcast
[Raspberry Pi 4B Review] Install Libreelec system on Raspberry Pi 4 and install plug-ins to watch IPTV live broadcastLibreelec is simply a Linux that meets the minimum requirements for Kodi . Libreele...
tagetage Special Edition for Assessment Centres
Industrial Sensor Selection Method
The emergence of sensors is not surprising. It has brought convenience to people's lives, so the principles and structures of sensors vary greatly. If something is measured by a sensor and it is inacc...
wxhxkj Sensor
The same via can have different impedances???
Author: Huang Gang, a member of Yibo Technology Expressway MediaTwo members of Mr. High Speed conducted impedance tests on the processed PCB board. The impedances they tested were very different. Can ...
yvonneGan PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号