24 ~ 50W AC-DC Single Output and Medical Type Desktop
Features :
MES50A
series
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage / Over temp.
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: Top switch circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
2 years warranty
EN 60601-1
IEC 60601-1
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
MES50A-0R1B MES50A-1R1B
MES50A-1-1R1B
MES50A-2P1J MES50A-3P1J MES50A-4P1J MES50A-5P1J MES50A-6P1J MES50A-8P1J
MES50A-0
Note.2
3.3V
MES50A-1
5V
7.5A
0 ~ 7.5A
37.5W
50mVp-p
6.0%
1.0%
6.0%
MES50A-1-1 MES50A-2
7.5V
5.33A
0 ~ 5.33A
40W
75mVp-p
5.0%
1.0%
5.0%
9V
5.0A
0 ~ 5.0A
45W
90mVp-p
5.0%
1.0%
5.0%
MES50A-3
12V
4.16A
0 ~ 4.16A
50W
100mVp-p
3.0%
1.0%
3.0%
MES50A-4
15V
3.33A
0 ~ 3.33A
50W
100mVp-p
3.0%
1.0%
3.0%
MES50A-5
18V
2.77A
0 ~ 2.77A
50W
150mVp-p
3.0%
1.0%
3.0%
MES50A-6
24V
2.08A
0 ~ 2.08A
50W
150mVp-p
2.0%
1.0%
2.0%
MES50A-8
48V
1.04A
0 ~ 1.04A
50W
200mVp-p
2.0%
1.0%
2.0%
7.5A
0 ~ 7.5A
24.75W
RIPPLE & NOISE (max.)
Note.3
50mVp-p
Fixed
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.4
8.0%
LINE REGULATION
LOAD REGULATION
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
OVERLOAD
Note.5
Note.6
1.0%
8.0%
SETUP, RISE, HOLD UP TIME
300ms, 50ms, 16ms at full load
90 ~ 264VAC 135~370VDC
47~63Hz
60%
90A / 230VAC
0.5mA / 240VAC
150 ~ 350% rated output power
112 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 150% rated output voltage
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Tj 135 typically (IC1) detect on main control IC
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
0 ~ +65 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / ( 0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL2601-1, IEC60601-1, EN60601-1 approved
I/P-O/P: 5656VDC , I/P-FG: 2828VDC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25
Compliance to EN55011(CISPR11) class B
Compliance to EN61000-3-2,3
Compliance to EN60601-1-2 (EN61000-4-2,3,4,5,6,8,11) light industry level, criteria A
-----
147*75.5*43.2mm (L*W*H)
0.55Kg ; 36pcs / 21Kg / CARTON
See page 2, Other type available by customer requested
See page 2, Other type available by customer requested
/ 70% RH
67%
70%
72%
74%
75%
78%
78%
80%
1.5A / 100VAC
INPUT
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note. 7)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
PLUG
CABLE
CONNECTOR
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:MES50A-SPEC 2007-05-14