EEWORLDEEWORLDEEWORLD

Part Number

Search

AST0210202

Description
Strip Terminal Block,
CategoryThe connector    terminals   
File Size171KB,1 Pages
ManufacturerMETZ CONNECT
Websitehttp://www.metz-connect.com/
Download Datasheet Parametric View All

AST0210202 Overview

Strip Terminal Block,

AST0210202 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Terminal and terminal strip typesSTRIP TERMINAL BLOCK
Base Number Matches1
Previously type 542
Previously type 602/502
Complete cross reference see page EA-6
mm to inch
1 inch = 25.4 mm
1 mm = .040 inches
Complete cross reference see page EA-6
Note
!
We have changed the
SPRINGCON part numbers.
Complete cross reference
see page EA-6.
Designed to IEC 60664-1
Designed to IEC 60664-1
AST
AST
without
eccentric lever
AST
with long
eccentric lever
06
02
150 V
10 A
18 - 28 AWG
.8 mm square
1.3 mm
5 mm
01
150 V
8A
20 - 28 AWG
.8 mm square
1.3 mm
5 mm
with short
eccentric lever
Electrical Data
Voltage
Current
Wire Range
Square pin
PCB hole diameter
Wire strip length
Electrical Data
Voltage
Current
Wire Range
Square pin
PCB hole diameter
Wire strip length
Mechanical Data
Housing
Spring clamp
Contact pin
Colors
Pole sizes
UL 94V-0 -40 °F to 189 °F
(-40 °C to 105 °C)
stainless chrome
molybdenum steel
copper alloy, tin plated
gray
(optional colors see margin)
2 to 24
Mechanical Data
Housing
Eccentric lever
Spring clamp
Contact pin
Colors
Pole sizes
UL 94V-0 -40 °F to 189 °F
(-40 °C to 105 °C)
UL 94HB -40 °F to 230 °F
(-40 °C to 110 °C)
stainless chrome
molybdenum steel
copper alloy, tin plated
gray
(optional colors see margin)
2 to 24
Optional colors
black, light blue, green,
red, dark blue
Additional material data - pages EA-3 to EA-5
Additional material data - pages EA-3 to EA-5
Dimensions (mm)
Dimensions (mm)
L = (circuits - 1) x centerline + 3.9
L = (circuits - 1) x centerline + 3
Suffixes for color
suffix
02
04
05
06
08
13
color
black
gray (standard)
light blue
green
red
dark blue
Part Numbers
AST06
(other circuits please consult factory)
Complete the part number
by adding the pole size.
Part Numbers
AST02
(other circuits please consult factory)
Complete the part number
by adding the pole size.
centerline 2.5 mm
Part No.
AST06 1
XX
02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
centerline 2.5 mm
Part No.
AST02 1
AST01
centerline 2.5 mm
XX
02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
Part No.
AST01 1
XX
For different sequences of
colors within the same termi-
nal block, i.e. black, red,
green, add suffix
99
multiple color
Please attach the color
sequence to your order or
consult factory.
XX
= color suffix - Please replace “XX” by the requested
color suffix (see margin).
RIA electronic, Inc.
430 Industrial Way West, Eatontown, NJ 07724
phone 1-888-722-5625
fax 732-389-9066
www.riaelectronic.com
XX
= color suffix - Please replace “XX” by the requested
color suffix (see margin).
EA-7
Subject to technical changes and printing errors.
E
[National Competition Interview] “Three weaklings” won the first prize for question H, and the winners who won by luck are here! ?
Are the first prize winners of national competitions usually like this? An enthusiast who has been disassembling and assembling radios and televisions since childhood, a second-generation electronic e...
nmg Electronics Design Contest
Kuyuan Electric Allegro video training
Allegro is an advanced PCB design and routing tool launched by Cadence. Allegro provides a good and interactive working interface and powerful and complete functions. The combination of its front-end ...
EE大学堂 Training Edition
What are the differences between precision op amps, instrument op amps, and general-purpose op amps?
1. What are the differences between precision op amps, instrument op amps, and general op amps? General op amps seem to be commonly used op amps, and their performance seems to be average. I don't kno...
bigbat Analog electronics
TI Engineer's Annual Review: Selected Q&A on Amplifiers, Interface/Clocking, and More
Interface/clock related: In our daily selection, we are often confused by these three names, and we don’t know the specific differences between them, so we will briefly explain them here: First, Repea...
eric_wang Analogue and Mixed Signal
Ten key takeaways about the Internet of Things
No time? Start here! This quick list summarizes the main points of the book. Read the main points in this chapter, and if there are any that interest you, check out the more complete explanations in t...
石榴姐 RF/Wirelessly
Assisting RF chip testing
RF components and RF chips are the core of wireless connections and an important part of the semiconductor industry. With the advent of 5G and WIFI6, RF technology has also encountered new challenges ...
SZHY_ic_socket RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号