EEWORLDEEWORLDEEWORLD

Part Number

Search

GHM0050MD601A3

Description
Absolute Magnetostrictive Sensor, 50mm Min, 2540mm Max, 20-0mA
CategoryThe sensor    Sensor/transducer   
File Size515KB,8 Pages
ManufacturerMTS Sensors
Websitehttps://www.mtssensors.com
Download Datasheet Parametric View All

GHM0050MD601A3 Overview

Absolute Magnetostrictive Sensor, 50mm Min, 2540mm Max, 20-0mA

GHM0050MD601A3 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
Other featuresREVERSE ACTING OUTPUT, INFINITE RESOLUTION
body height68 mm
Body length or diameter46 mm
shellALUMINIUM
Linearity(%)0.02 %
Maximum measuring range (mm)2540 mm
Minimum measuring range (mm)50 mm
Maximum operating temperature80 °C
Minimum operating temperature-40 °C
Output interface typeRS-485
Output range20-0mA
Output typeANALOG CURRENT
Repeatability0.0025
Response time1 µs
Sensor/Transducer TypeLINEAR POSITION SENSOR,MAGNETOSTRICTIVE,ABSOLUTE
Maximum supply voltage28.8 V
Minimum supply voltage20.4 V
Termination typeCONNECTOR
Base Number Matches1
Temposonics
®
Magnetostrictive Position Sensors
G-Series Linear Position Sensor
Analog and Digital Pulse Outputs
Product Specification
550959 E
Temposonics Model GP
Temposonics Model GH
I
Temposonics next generation platform optimized for performance,
durability and functionality
I
Advanced sensor communication via serial RS-422, RS-485 or Infrared
interfaces
I
Enhanced diagnostics and programming capability using serial
communications and visual LEDs
I
Designed for backwards compatibility with legacy Temposonics products
The Benefits of Magnetostrictive Sensing
Temposonics linear sensors use the
time-based magnetostrictive posi-
tion sensing principle developed by
MTS. Within the sensing element, a
sonic strain pulse is induced in a
specially-designed magnetostrictive
waveguide by the momentary inter-
action of two magnetic fields. One
field comes from a movable perma-
nent magnet that passes along the
outside of the sensor. The other
field comes from an “interrogation”
current pulse applied along the
waveguide. The resulting strain
pulse travels at ultrasonic speed
along the waveguide and is detected
at the head of the sensing element.
The position of the magnet is deter-
mined with high precision and speed
by accurately measuring the elapsed
time between the application of the
interrogation pulse and the arrival of
the resulting strain pulse with a high
speed counter. Using the elapsed
time to determine position of the
permanent magnet provides an
absolute position reading that never
needs recalibration or re-homing
after a power loss. Non-contact
sensing eliminates wear, and guar-
antees the best durability and output
repeatability.
All specifications are subject to change. Please contact MTS for specifications that are
critical to your needs. Refer to
“How To Order”
on page 7 or go to www.temposonics.com
for the latest list of G-Series support documentation.

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号