Internal Terminations DC-26.5GHz SPDT Switch
The CRT-53 Switch is an internally terminated, broadband, SPDT, electromechanical coaxial
switch designed to switch a microwave signal from a common input to either of two outputs. The
characteristic impedance is 50 Ohms. Internal terminations provide an impedance match for the
unselected port. The switches are small with the minimum spacing that is compatible with SMA
connectors.
Specifications
RF Contacts:
Actuator
Break before make
Voltage (VDC) 20
O
C
Current (mA)
Switching Time:
Terminations:
Connectors:
Weight:
10 msec max
The CRT-53 is available with either a failsafe or latching actuator.
12
15
28
420 350 200
H = 1.75 MAX. STD MODEL
H = 1.86 MAX. TTL MODEL
50 Ohm 2 Watts CW max
SMA (f)
2.65 oz. max
MIL-STD-202 Method 213, Condition D
(500G Non Operating)
MIL-STD-202 Method 214, Condition D
(10G RMS Non Operating)
Moisture Seal Available
5
Million
Cycles
Temperature Range:
-55
O
C to +85
O
C (Operating)
Shock:
Vibration:
Humidity:
Typical
Contact Life:
DC to 6 GHz: 0.05 dB
Insertion Loss Repeatability (1 Million Cycles):
DC to 20 GHz: 0.1 dB
Typical Performance
Return Loss
15
25
RF Power Handling (Non-terminated)
3000
800
400
Sta
Power CW (Watts)
nda
rd S
MA
200
Co
nne
cto
rs
80
40
0.01
0.0
Frequency GHz
26.5
10
0.1
0.4
IL dB
1.0
4.0
Frequency GHz
10
18
26.5
Specifications
DC-6 GHz 6-12 GHz 12-18 GHz 18-26.5GHz
1.40:1
0.40 dB
60.0 dB
1.50:1
0.50 dB
60.0 dB
1.80:1
0.70 dB
50.0 dB
VSWR (max)
1.25:1
Insertion Loss (max) 0.20 dB
Isolation (min)
70.0 dB
0.01
Frequency GHz
26.5
Specifications subject to change without notice.
www.teledynecoax.com
email: coax@teledyne.com
Tel: (800) 351-7368
10/2007
Isolation dB
60
70
80
90
Internal Terminations DC-26.5GHz SPDT Switch
Elite
CRT-53
Latching
Indicators
TTL
Analog
Part Numbering System for CRT-53 (Latching)
CRT-53 S 6 O -T
Series
Connectors
Actuator Voltage
Connector
S: SMA Female
Actuator Voltage
Actuator Voltage
6:6:28Vdc Latching #
28Vdc Failsafe
7:7:15Vdc Latching #
15Vdc Failsafe
8:8:12Vdc Latching #
12Vdc Failsafe
Actuator Type
O: No Indicator Contacts
C: Indicator Contacts
D: Self Cutoff Only
E: Indicators and Self
Cutoff
Options
T: TTL Drivers with Diodes
R: Positive + Common
Options
Actuator Type
For other options contact Factory
Specifications subject to change without notice.
www.teledynecoax.com
email: coax@teledyne.com
Tel: (800) 351-7368
10/2007