SERIES
VV VVP VVN
6,000 to 10,000 VDC OUTPUTS
Isolated, Single Output Modules
6,000 to 10,000 Volts DC Output
Output VDC Proportional to Input VDC
Up to 6 Watts
High Efficiency
VV: For Isolated applications, positive or negative outputs
VVP: For positive output, with common grounds
VVN: for negative output, with common grounds
Low Profile 0.500" Height
For Special Voltages or Military Upgrades Consult Factory 8004311064
This series of "High Voltage" DCDC Converters are designed to allow you to vary the input voltage in order to vary the output voltage. The seven standard
input voltage ranges will allow you to operate these units as fully isolated and the "P" or "N" designation as positive or negative DC outputs from 6,000 to
10,000 VDC from almost any DC source. These single output, isolated units will operate over the temperature range of 25º C to +70º C with no heat sink or
electrical derating required.
FEATURES
Up to 6 watts @ 70º C ambient
Encapsulated semiconductors conservatively rated for maximum reliability
Ultraminiature size 0.500" height
7 input voltages standard
105 models standard
High Efficiency: Up to 85
Test Conditions: 25º C
Operating Temperature Range: 25º C to +70º C
Storage Temperature: 55º C to +125º C
Operating Frequency: 1525 KHz
Output Temperature Coefficient: 0.02%/ºC
TYPICAL CHARACTERISTICS:
OPTIONS AVAILABLE
Per Mil. Std. 883
Expanded operating temp. (40º C to +85º C)
Stabilization Bake (125º C ambient)
Temperature Cycle (55º C to +125º C)
Hi Temp, burn in
SERIES VV
FOR ISOLATED OPERATION
Input and output grounds floating Isolated from each other
Output voltage can be positive or negative
PICO
Part
Number
Input Voltage
Range
(VDC)
Min
2.0
2.0
2.0
2.0
2.0
3.5
3.5
3.5
3.5
3.5
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
7.0
7.0
7.0
7.0
7.0
8.0
8.0
8.0
8.0
8.0
15.0
15.0
15.0
15.0
15.0
Max
5
5
5
5
5
9
9
9
9
9
12
12
12
12
12
15
15
15
15
15
24
24
24
24
24
28
28
28
28
28
48
48
48
48
48
*
Maximum
Load Current
(mA)
Minimum Load
Current 5%
0.833
0.714
0.625
0.556
0.500
1.000
0.857
0.750
0.667
0.600
1.000
0.857
0.750
0.667
0.600
1.000
0.857
0.750
0.667
0.600
1.000
0.857
0.750
0.667
0.600
1.000
0.857
0.750
0.667
0.600
1.000
0.857
0.750
0.667
0.600
Output Voltage
Range
(VDC)
Min
V Out
625
1100
1750
1400
2150
2000
2250
2500
2900
3100
1700
1900
2100
2200
2100
1700
1900
2150
2300
2200
1400
1600
1750
1800
1500
1350
1500
1600
1800
2200
1600
1700
1850
2000
2200
Max
V Out
6000
7000
8000
9000
10,000
6000
7000
8000
9000
10,000
6000
7000
8000
9000
10,000
6000
7000
8000
9000
10,000
6000
7000
8000
9000
10,000
6000
7000
8000
9000
10,000
6000
7000
8000
9000
10,000
Max.
Output
Power
(Watts)
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Typical
Efficiency
@ Full Load
at Max VIN
(%)
79
77
76
75
75
82
80
79
77
76
83
81
79
77
76
80
80
79
77
76
81
81
80
78
77
82
80
79
78
77
80
79
79
78
77
Typical
Output
Voltage
Ripple @
Full Load
(%)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Price
(US $)
5VV6
5VV7
5VV8
5VV9
5VV10
9VV6
9VV7
9VV8
9VV9
9VV10
12VV6
12VV7
12VV8
12VV9
12VV10
15VV6
15VV7
15VV8
15VV9
15VV10
24VV6
24VV7
24VV8
24VV9
24VV10
28VV6
28VV7
28VV8
28VV9
28VV10
48VV6
48VV7
48VV8
48VV9
48VV10
216.39
262.18
307.98
353.77
399.57
216.39
262.18
307.98
353.77
399.57
216.39
262.18
307.98
353.77
399.57
216.39
262.18
307.98
353.77
399.57
216.39
262.18
307.98
353.77
399.57
216.39
262.18
307.98
353.77
399.57
216.39
262.18
307.98
353.77
399.57
* Maximum load current remains constant throughout input voltage range.
Safety Note: The high voltage power supplies described in this datasheet generate voltages which can be lethal. They should only be installed and used by personnel who have
received the appropriate training and who are fully aware of the hazards that exist.
SERIES VV
FOR ISOLATED OPERATION
Input and output grounds floating Isolated from each other
Output voltage can be positive or negative
28VV6P
28VV7P
28VV8P
28VV9P
28VV10P
8.0
8.0
8.0
8.0
8.0
Input Voltage
Range
(VDC)
Min
15.0
15.0
15.0
15.0
15.0
28
28
28
28
28
1.000
0.857
0.750
0.667
0.600
*
Maximum
Load Current
(mA)
Minimum Load
Current 5%
1.000
0.857
0.750
0.667
0.600
1350
1500
1600
1800
2200
6000
7000
8000
9000
10,000
6
6
6
6
6
Max.
Output
Power
(Watts)
6
6
6
6
6
82
80
79
78
77
Typical
Efficiency
@ Full Load
at Max VIN
(%)
80
79
79
78
77
2
2
2
2
2
Typical
Output
Voltage
Ripple @
Full Load
(%)
2
2
2
2
2
216.39
262.18
307.98
353.77
399.57
PICO
Part
Number
Output Voltage
Range
(VDC)
Min
V Out
1600
1700
1850
2000
2200
Max
V Out
6000
7000
8000
9000
10,000
Price
(US $)
Max
48
48
48
48
48
48VV6P
48VV7P
48VV8P
48VV9P
48VV10P
216.39
262.18
307.98
353.77
399.57
* Maximum load current remains constant throughout input voltage range.
Safety Note: The high voltage power supplies described in this datasheet generate voltages which can be lethal. They should only be installed and used by personnel who have
received the appropriate training and who are fully aware of the hazards that exist.
SERIES VVP
For use when input and output grounds are connected and a positive output voltage is
required
For Positive Output Voltage
BOTTOM VIEW
Measurements are in Inches
Typical Weight: 45 Grams
PICO 28VV10P