EEWORLDEEWORLDEEWORLD

Part Number

Search

PCLH-206A1MSP,000

Description
POWER/SIGNAL RELAY, DPST, MOMENTARY, 1400mW (COIL), 10A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT
CategoryMechanical and electronic products    relay   
File Size318KB,4 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

PCLH-206A1MSP,000 Overview

POWER/SIGNAL RELAY, DPST, MOMENTARY, 1400mW (COIL), 10A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT

PCLH-206A1MSP,000 Parametric

Parameter NameAttribute value
MakerTE Connectivity
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresOPERATE VOLTAGE(AC): 96 V, RELEASE VOLTAGE(AC): 36 V
body width21.2 mm
body height33.6 mm
Body length or diameter27.5 mm
Coil current (AC) maximum value0.035 A
Coil power1400 mW
Coil resistance3400 Ω
Maximum coil voltage (AC)120 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load15A@120VAC
Maximum contact current (AC)15 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@24VDC
Maximum contact voltage (AC)120 V
Maximum contact voltage (DC)24 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Manufacturer's serial numberPCLH
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours20 ms
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
physical size27.5mm X 21.2mm X 33.6mm
GuidelineCSA; UL
Relay actionMOMENTARY
Relay functionDPST
Relay typePOWER/SIGNAL RELAY
release time20 ms
surface mountNO
Termination typeSOLDER
Base Number Matches1
Catalog 1308242
Issued 3-03 (PDF Rev. 3-04)
OEG
PCL/PCLH series
3A, 5A, 10A, 15A General Purpose
Miniature Relay
Factory Automation, Process Controls,
Electrical Panels, etc.
UL File No. E58304
CSA File No. LR48471
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Small size, 3A, 5A, 10A and 15A switching capacity.
• Meets UL and CSA requirements.
• 1 pole, 2 poles and 4 poles contact arrangements.
• AC and DC coils with UL Class F (155°C) coil insulation system standard.
• Optional flange mount case.
• Plug-in terminals or PCB terminals.
Coil Data@ 20°C
Rated Coil
Voltage
(VAC)
6
12
24
48
100
110/120
200
220/240
PCL AC Coil
Must Operate Must Release
Coil
Voltage
Resistance
Voltage
(VAC)
(ohms)±10%
(VAC)
10
40
160
600
2,800
3,400
11,000
13,600
Nominal Coil
Power
(VA)
Contact Data @ 20°C
Arrangements:
1 Form A (SPST-NO),
1 Form C (SPDT),
2 Form A (DPST-NO),
2 Form C (DPDT),
4 Form A (4PST-NO),
4 Form C (4PDT).
Material:
Ag, Ag Alloy.
Max.Switching Rate:
300ops./min.(Mechanical).
30ops./min.(Electrical).
Expected Mechanical Life:
100 million operations (no load).
Expected Electrical Life:
100,000 operations (rated load).
Minimum Load:
100mA @ 5VDC.
Initial Contact Resistance:
50milliohms @ DC6V,1A.
80% max.
30% min.
abt. 1.4
PCL DC Coil
Rated Coil
Voltage
(VDC)
6
12
24
48
100/110
Coil
Must Operate
Resistance
Voltage
(ohms)±10%
(VDC)
40
160
650
2,600
11,000
Must Release
Voltage
(VDC)
Nominal Coil
Power
(W)
abt. 0.9
80% max.
10% min.
abt. 1.1
Contact Ratings
PCL-4
3A @ AC250V/DC24V resistive.
PCL-2
5A @ AC250V/DC24V resistive.
PCLH-2 15A @ AC120V resistive.
10A @ AC250V/DC24V resistive.
PCLH-1 15A @ AC250V/DC24V resistive.
Max. Switched Current:
PCL-4
3A.
PCL-2
5A.
PCLH-2
15A.
PCLH-1
15A.
Max. Switched Power:
PCL-4
660VA, 72W.
PCL-2
1,100VA, 120W.
PCLH-2
3,168VA, 240W.
PCLH-1
3,300VA, 360W.
Ratings:
Operate Data @ 20°C
Must Operate Voltage:
AC 80% of nominal voltage or less.
DC 80% of nominal voltage or less.
Must Release Voltage:
AC 30% of nominal voltage or more.
DC 10% of nominal voltage or more.
Operate Time:
AC 20ms max.
DC 15ms max.
Release Time:
AC 20ms max.
DC 8ms max.
Initial Dielectric Strength
Between Open Contacts:
1,000VAC 1minute.
Between Adjacent Contact Terminals:
1,500VAC 1minute.
Between Contacts and Coil:
2,000VAC 1minute.
Surge Voltage (Coil-Contact):
3,000V(1.2/50µs).
Environmental Data
Temperature Range:
Operating:
-10°C to +55°C.
Humidity:
45 to 85%. (Non-condensing).
Vibration, Operational:
10 to 55Hz 1.0mm double amplitude.
Mechanical:
10 to 55Hz 1.0mm double amplitude.
Shock, Operational:
100m/s
2
(abt. 10G).
Mechanical:
1,000m/s
2
(abt. 100G).
Initial Insulation Resistance
Between Open Contacts:
1,000Mohms @ 500VDC.
Between Adjacent Contact Terminals:
1,000Mohms @ 500VDC.
Between Contacts and Coil:
1,000Mohms @ 500VDC.
Coil Data
Voltage:
AC 6 - 240V.
DC 6 - 110V.
Nominal Power:
AC abt. 1.4VA/1.2VA (50Hz/60Hz).
DC abt. 0.9W.
Coil Temperature Rise:
AC 60°C max.
DC 50°C max.
Max. Coil Power:
110% of nominal voltage.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Mechanical Data
Termination:
Plug-in, PCB.
Enclosure:
Snap-on cover.
Weight:
1.26 oz (32g) approximately.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
713
Refer to inside back cover.
Why is negative feedback introduced in the amplifier circuit?
(1) Why do we usually introduce feedback networks in amplifier circuits?The main purpose of introducing negative feedback is to make the amplifier circuit work in the linear region and make the output...
fish001 Analogue and Mixed Signal
OCP China Day 2021 is about to be held, and we invite you to come and discuss the most cutting-edge industry applications of open computing!
OCP China Day 2021 will be held at Kerry Hotel Beijing on July 27. We sincerely invite you to participate in this conference. The theme of this conference is "Another Decade of Open Computing: Carbon ...
eric_wang Integrated technical exchanges
What are the main controllers in industry and what are the remote communication methods?
[i=s]This post was last edited by Mr. Lan on 2020-3-9 09:49[/i]The main controls are: 1.PLC, advantages: relatively mature technology, stable performance, low cost, simple programming 2. Single chip m...
蓝先生 Industrial Control Electronics
C6678: How does the malloc function do byte alignment
The size of the matrix is a function parameter. We want to apply for dynamic cache as a dynamic array, but many subsequent vector operations must be byte-aligned to be calculated, such as DSPF_sp_vecr...
alan000345 Microcontroller MCU
MOS driving voltage problem
Does the Vgs of a high-power MOS or IGBT provide a negative voltage when it is turned off, which can speed up the turn-off speed of the tube? Does a device like IGBT require a "larger drive current" (...
bigbat Power technology
Detailed explanation of ADC of MSP430 microcontroller
The ADC analog-to-digital converter is an important on-chip peripheral of the 430 microcontroller, and it is often needed in development. Based on the user manual and my personal learning experience, ...
fish001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号