FEATURES
APPLICATIONS
High dvdt
–
Good Pulse Current
–
Stable with Temperature and Frequency
Inverters/Converters
–
Power Semiconductor Circuits
–
Induction Heating
–
Switching Power Supplies
-55°C to +85°C
+10% at 1 kHz, 25°C
+5% optional
WVDC
700
850
SVDC
1000
1200
WVDC
700
850
VAC
420
450
Frequency
C<0.047uF
(kHz)
1
0.06%
1000
1400
1000
480
1200
1600
1200
500
1500
2000
1500
575
C>1uF
0.06%
2000
2400
2000
630
2500
3000
2500
700
3000
3500
3000
750
Operating Temperature Range
Capacitance Tolerance
Surge Voltage(SVDC)
AC voltage (50/60 Hz)
Dissipation Factor (MAX)
25°C
Insulation Resistance
@25°C (<70% RH)for 1 minute at
100VDC applied
Self Inductance
Capacitance Drift Factor
0.047>C>1uF
0.05%
30000 MΩxμF
(not to
exceed 30GΩ)
<1 nano-Henry per mm of lead spacing
<0.5% after 2 years at 40°C
30000 hours @VAC, 70°C
100000 hours @VDC, 70°C
Capacitance Change
<3% of initially measured value
300/ billion component hours
56 days at 40°C with 90 to 95%RH, +40°C and no voltage applied
Capacitance Change
<2% of initially measured value
Dissipation Factor
<0.001 at 1kHz and 25°C
Insulation Resistance
>50% of maximum specified value
<1 nano-Henry per mm of body length and lead length
<1.0% after 2 years at 40°C
-200 ppm/°C, +100ppm/°C
Terminal to case
3kVAC, 50/60Hz applied
160% of rated VDC or 200% VDC
between the leads and case for
applied for 2 Seconds and 25°C
60 seconds
Polypropylene
Double Metallized film with internal series connections
Flame Retardant polyester tape wrap (UL 501) with epoxy resin end
fill(UL94V0)
Lead free tinned copper leads
Terminal to Terminal
Life Expectancy
Failure Quota
Damp Heat test
Self Inductance
Capacitance Drift Factor
Capacitance Temperature
Coefficient
Dielectric Strength
Dielectric
Construction
Coating
Leads