General Description:
22 AWG solid tinned copper conductors, twisted pairs, Datalene® insulation, individually shielded with
100% Beldfoil® shield, 24 AWG solid tinned copper drain wire each pair, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (mm)
2
22
Solid
TC - Tinned Copper 0.64516
Total Number of Conductors:
4
Insulation
Insulation Material:
Insulation Trade Name Insulation Material
Datalene®
PO w/Foam PO - Polyolefin w/Foam Polyolefin
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
24
Inner Shield Drain Wire Stranding:
Inner Shield Drain Wire Conductor Material:
Solid
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter:
5.131 x 9.144 mm
Pair
Pair Color Code Chart:
Number Color
1
2
Blue & White/Blue
Orange & White/Orange
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +75°C
49.111 Kg/Km
137.894 N
50.800 mm
Page 1 of 3
04-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
7838A Multi-Conductor - T1/DS1 Central Office Interconnect/Cross Connect Cable
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU Directive 2011/65/EU (ROHS II):
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CM
CM
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.78744
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
47.5745
Nominal Velocity of Propagation:
VP (%)
72
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
54.7927
Nom. Attenuation:
Attenuation (dB/100m)
4.3 @ 772 KHz
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
3.5 Amps per conductor @ 25°C
Differential Impedance @ 1 MHz:
105
Notes (Overall)
Notes:
Single conductors are dual insulated. The outer layer of insulation must be stripped off before attaching modular connectors.
Use a stripping tool such as Cooper Tools Xcelite model 103-S, or equivalent with a mechanical stop to avoid nicking the inner
insulation. RJ-45 Compatible.
Put Ups and Colors:
Item #
7838A 0601000
Putup
305 MT
Ship Weight
16.783 KG
Color
CHROME
Notes
C
Item Desc
2 FS PR #22 PP/FPE PVC PARA
Page 2 of 3
04-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
7838A Multi-Conductor - T1/DS1 Central Office Interconnect/Cross Connect Cable
7838A 0602000
7838A 0605000
Notes:
C = CRATE REEL PUT-UP.
610 MT
1,524 MT
33.566 KG
81.647 KG
CHROME
CHROME
C
C
2 FS PR #22 PP/FPE PVC PARA
2 FS PR #22 PP/FPE PVC PARA
Revision Number: 0
© 2013 Belden, Inc
All Rights Reserved.
Revision Date: 09-24-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Page 3 of 3
04-30-2013