1200RG3F029B2DA

Description
Strain Guage Sensor, Gage, -15Psi Min, 15Psi Max, 0.5%, 0-5V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

1200RG3F029B2DA Overview

Strain Guage Sensor, Gage, -15Psi Min, 15Psi Max, 0.5%, 0-5V, Cylindrical

1200RG3F029B2DA Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.5%
shellSTAINLESS STEEL
Nominal offset0V
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0-5V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port typeSS NOSE CONE
Maximum pressure range15 Psi
Minimum pressure range-15 Psi
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeDIN 9.4MM W/O MATE
Base Number Matches1
Embedded Linux Development Process
In the process of learning embedded development, especially when you are just getting started, including various tutorials, they are all about learning Linux, and rarely about how to use Linux to deve...
Jacktang Microcontroller MCU
Parameters returned by the BLE5.0 protocol stack
This is a callback function for registering a service instance. I would like to ask what the parameters are. The first one is the event type, etc. What is the second one? Some cases assign values to i...
Liquor@ RF/Wirelessly
Safety distance and related safety requirements
1. Electrical clearance: the shortest distance between two adjacent conductors or between a conductor and the adjacent motor housing surface measured along the air. 2. Creepage distance: The shortest ...
ohahaha PCB Design
BQ24072 output terminal solution sharing
[b][size=4]Question: Does the output of BQ24072 need to be boosted by dcdc before being stepped down to 3.3v? [/size][/b] [size=4]The system needs to supply 3.3 1.8 1.2V. Currently, bq24072 is directl...
qwqwqw2088 Analogue and Mixed Signal
Design of 10kW Full-bridge Phase-Shifted ZVSPWM Rectification Module
In large power plants, the required DC load is relatively large, and the capacity of the battery is usually above 2000A·h. If a conventional 10A or 20A switching rectifier module is used, generally 20...
zbz0529 Power technology
Liquid Measurement Technology: From Water to Blood
Determining the composition and quality of liquids is essential for many applications. The prime example is water, which is the world's most precious native resource. Water purification and water filt...
eric_wang Test/Measurement

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号