EEWORLDEEWORLDEEWORLD

Part Number

Search

F.MR.2A525.26

Description
Mains Power Connector, 2.5A, 250VAC, Male, Plug
CategoryThe connector    The connector   
File Size119KB,2 Pages
ManufacturerNissei Electric Co.,Ltd.
Download Datasheet Parametric View All

F.MR.2A525.26 Overview

Mains Power Connector, 2.5A, 250VAC, Male, Plug

F.MR.2A525.26 Parametric

Parameter NameAttribute value
MakerNissei Electric Co.,Ltd.
Reach Compliance Codeunknown
Is SamacsysN
Other featuresSTANDARD: IEC 60320, FASTON
Body/casing typePLUG
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2.5A, 250VAC
Manufacturer's serial numberF.MR
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialMETAL
Total number of contacts3
Base Number Matches1
IEC Inlet Filters
F.MH-F.MK-F.ML-F.MM-F.MP-F.MQ-F.MR-F.MS
series
With fuse holder, bipolar switch and voltage selector
This series gives a high level of suppression within a compact
enclosure. The IEC 60320 inlet power entry module combines 1 or 2
fuse holders for US and IEC fuses, with a bipolar rocker switch, earth
choke and input voltage selector.
Designed for use in business, consumer, test and medical equipment
for international markets.
Current ratings from 1A to 6A
Comprehensive range of filter performance options
Integral single or twin fuse holder
Optional voltage selector
Optional earth line choke
Horizontal or vertical mounting
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320,
fuse holder for 1 fuse (F.MH. - F.ML. - F.MP. - F.MR)
or 2 fuses (F.MK. - F.MM. - F.MQ. - F.MS)
5 x 20mm (IEC) or 6.3 x 32mm (US),
bipolar rocker switch,
voltage selector 110/220Vac (F.MH - F.MK - F.ML
- F.MM only); internal components sealed with
self-extinguishing resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.8mm (OUTPUT);
ground terminal connected to case.
Mounting:
F.MH, F.MK, FML, FMM versions now available in
vertical mounting version - (F.**.***.**.**.010) with
no approvals.
Filter Range
(example pt no. - F.MH.01A.20.25)
Code
20.- -
01A 24.- -
30.- -
34.- -
21.- -
2A5 25.- -
31.- -
35.- -
22.- -
04A 26.- -
32.- -
36.- -
23.- -
06A 27.- -
33.- -
37.- -
20.- -
01A 24.- -
30.- -
34.- -
21.- -
2A5 25.- -
31.- -
35.- -
22.- -
04A 26.- -
32.- -
36.- -
23.- -
06A 27.- -
33.- -
37.- -
I
R
L
1
(A) (mH)
2 x 10
1
2 x 10
2 x 22
2 x 22
2x2
2.5 2 x 2
2x8
2x8
2x1
4
2x1
2x8
2x8
2x1
6
2x1
2 x 2.5
2 x 2.5
2 x 10
1
2 x 10
2 x 22
2 x 22
2x2
2.5 2 x 2
2x8
2x8
2x1
4
2x1
2x8
2x8
2x1
6
2x1
2 x 2.5
2 x 2.5
L
2
Cx
1
(mH) (µF)
0.22
Cx
2
(µF)
0.1
Cy
(pF)
2 x 4700
2 x 4700
2 x 4700
F.MH.
F.MK.
F.MQ.
F.MS.
0.22
0.1
2 x 4700
2 x 4700
0.22
0.1
2 x 4700
2 x 4700
0.22
0.1
2 x 4700
2 x 4700
0.1
2 x 4700
0.65 0.22
2 x 4700
0.1
2 x 4700
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Bipolar rocker
Switches:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
10(4)A / 250Vac (Rated current),
50000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Voltage selector:
110-220Vac (F.MH - F.MK - F.ML - F.MM only).
Leakage current (I
L
):
at 220V, 50Hz, max value
F.ML.
F.MM.
F.MP.
F.MR.
0.65 0.22
2 x 4700
0.1
2 x 4700
0.65 0.22
2 x 4700
0.1
2 x 4700
2 x 0.003
0.65 0.22
l
L
(mA)
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
R
(MΩ)
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.33
No approvals, Circuit Diagram D
No approvals, Circuit Diagram C
Not applicable to FMP,FMR
Approvals
32
.010 = Vertical mounting option (addition to standard pt no.)
25 = Rocker switch
26 = Illuminated rocker switch
Circuit Diagram:
H = 1 fuse
A
K = 2 fuses
L = 1 fuse + earth choke
B
M = 2 fuses + earth choke
P = 1 fuse, single pole switch (no voltage selector)
D
Q = 2 fuses, single pole switch (no voltage selector)
R = 1 fuse, double pole switch (no voltage selector)
C
S = 2 fuses, double pole switch (no voltage selector)
Macro base stations, distributed base stations, small base stations
Base stations are public mobile communication base stations, which are a form of radio stations. They refer to radio transceiver stations that transmit information to mobile phone terminals through mo...
兰博 RF/Wirelessly
How to integrate FreeRTOS on ARMv8-M architecture processor?
TrustZone technology is introduced in the Cortex-M series (Cortex-M33 and Cortex-M23) microcontrollers based on the ARMv8-M architecture. TrustZone enables two security domains in a single processor, ...
MamoYU Real-time operating system RTOS
[STM32WB55 Review] Play with the built-in Demo
On the back of the cardboard in the package of this kit, there is a text "Getting started" which introduces the demo that comes with the development board (already burned in). If I hadn't seen the pos...
cruelfox RF/Wirelessly
Reading Notes on the Good Book "Electronic Engineer Self-Study Handbook" 03 Program
[i=s]This post was last edited by qi777ji on 2021-8-18 10:02[/i]Today I read the chapters on MCU driver and programming. Although the MCU models involved are a bit old, it can be seen that the author ...
qi777ji Analog electronics
Base station interference source positioning system based on drone
Figure 1 is a schematic diagram of the positioning systemFigure 2 shows the structure of the positioning system Figure 3 shows the terminal interfaceThe invention relates to the field of communication...
cjc2308750 TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号