D200E
Series
Low Cost, 2W SIP
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
2W Output Power
•
Miniature SIP Case
•
UL Approved
(File E245422)
•
Single & Dual Outputs
•
1,000 VDC Isolation
•
>3.5 MHour MTBF
•
24 Standard Models
•
LOWEST COST!!
Input
Parameter
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
Min.
4.5
10.8
21.6
Typ.
5.0
12.0
24.0
Max.
5.5
13.2
26.4
0.3
Conditions
Dual Output , Balanced Loads
For Vin Change of 1%
Min.
Typ.
±1.0
±0.1
±1.2
100
120
±0.02
Momentary (1.0 Sec.)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
1,000
60
75
Conditions
Ambient
Min.
-40
-55
Free Air Convection
RH, Non-condensing
95
%
Typ.
+25
Max.
+85
+125
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Units
ºC
ºC
±0.03
150
Max.
±3.0
±1.0
A
Units
%
%
%
mV P - P
%
%/ºC
VDC
Units
Internal Capacitor
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
See Model Selection Guide
RoHS Compliant
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Case Size
(5V 12V & 24V Input Models)
Case Material
Weight
0.77 x 0.28 x 0.40 Inches (19.6 x 7.0 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
3.5
Typ.
Max.
Units
MHours
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
300
450
ºC
mW
VDC
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution:
Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D201E
D202E
D203E
D204E
D205E
D206E
D207E
D208E
D211E
D212E
D213E
D214E
D215E
D216E
D217E
D218E
D221E
D222E
D223E
D224E
D225E
D226E
D227E
D228E
Input
Voltage (VDC)
Nominal
Range
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
Output
Load
Current (mA)
Regulation
Voltage Current
Current
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)
494
30
5.0
400.0
40.0
15
488
30
9.0
222.0
23.0
15
476
30
12.0
167.0
17.0
15
476
30
15.0
133.0
14.0
15
488
30
±5.0
±200.0
±20.0
15
482
30
±9.0
±111.0
±12.0
15
470
30
±12.0
±83.0
±9.0
15
470
30
±15.0
±67.0
±7.0
15
203
15
5.0
400.0
40.0
15
201
15
9.0
222.0
23.0
15
196
15
12.0
167.0
17.0
15
196
15
15.0
133.0
14.0
15
201
15
±5.0
±200.0
±20.0
15
198
15
±9.0
±111.0
±12.0
15
194
15
±12.0
±83.0
±9.0
15
194
15
±15.0
±67.0
±7.0
15
100
8
5.0
400.0
40.0
15
99
8
9.0
222.0
23.0
15
97
8
12.0
167.0
17.0
15
97
8
15.0
133.0
14.0
15
99
8
±5.0
±200.0
±20.0
15
98
8
±9.0
±111.0
±12.0
15
96
8
±12.0
±83.0
±9.0
15
96
8
±15.0
±67.0
±7.0
15
Efficiency
(%, Typ)
81
82
84
84
82
83
85
85
82
83
85
85
83
84
86
86
83
84
86
86
84
85
87
87
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
Notes:
1. Output load regulation is specified for a load change of 10% to
100%.
2. These units should not be operated with a load under 10% of
full load. Operation at no-load may cause damage to the unit.
3. These converters will operate without external components.
However, when measuring output ripple, it is recommended
that an external ceramic capacitor be placed from the +Vout
pin to the -Vout pin for single output units and from each out-
put to common for dual output units. An input capacitor will
enhance stability over temperature and input line variations.
Recommended capacitor values are given in the table below.
For applications requiring very low output noise levels, a simple
LC filter should be effective.
Output Capacitor
Input
Vin
Vout
Capacitor
Single
Dual
5 VDC
4.7
µF
5 VDC 10.0
µF
4.7
µF
12 VDC
2.2
µF
9 VDC
4.7
µF
2.2
µF
24 VDC
1.0
µF
12 VDC 2.2
µF
1.0
µF
15 VDC 1.0
µF
0.47
µF
4. Dual output units may be connected to provide a 10V, 18V, 24V
or 30 VDC output. To do this, connect the load across the posi-
tive (+Vout) and negative (-Vout) outputs and float the output
common
5. It is recommended that a fuse be used on the input of a power
supply for protection. See the Model Selection table above for
the correct rating.
Derating Curve
g
Mechanical Dimensions
Pin Connections
Pin
1
2
4
Single
+Vin
-Vin
-Vout
Dual
+Vin
-Vin
-Vout
Pin
5
6
Single
No Pin
+Vout
Dual
Common
+Vout
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.01 (
±
0.25)
•
Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
www.micropowerdirect.com
•
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com