HES25-033500-1

Description
AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES
File Size303KB,2 Pages
ManufacturerHitron
Websitehttp://www.hitron-e.com/
Download Datasheet Compare View All

HES25-033500-1 Overview

AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES

H HiTRON
AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT
SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES
HES25 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC INPUT
DIVERSE WALLMOUNT AC PLUGS
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN55022 /FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
90-264Vac typical.
Input Connector:
Wallmount Format.
WM1/ WM2 (USA/Japan), WM3(Euro-Stecker).
WM5 (UK) / WM6 (Australia).
Input Frequency:
47-63Hz.
Inrush Current:
28A @230Vac typical.
Input Current:
0.6A @115Vac/0.3A @230Vac.
Dielectric Withstand:
Meet IEC60950.
EMI:
Meet EN55022/ FCC Class B.
Hold-up Time:
8mS @115Vac typical.
35mS @230Vac typical.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Wattage:
20-36 Watts typical.
Output Connector & Cord:
Optional.
Line Regulation:
0.1% typical.
Load Regulation:
±1.5-3% typical.
Noise & Ripple:
1.0% typical peak to peak.
OVP:
Built-in, Zener diode clamping.
Adjustability:
Factory set.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
Operating Temperature:
0 °C to room temperature.
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
0.04% /°C.
Cooling:
Free air convection.
Construction:
Impact resistant thermo-plastic
enclosure case.
Wallmount Format.
GENERAL SPECIFICATION
Efficiency:
71-85% typical.
Switching Frequency:
Approximate 70K Hz.
Circuit Topology:
Fixed Frequency Flyback circuit.
Transient Response:
Output voltage returns in less than
3mS following a 25% load change.
Safety Standard:
Meet UL60950/ EN60950 Class I & II.
Power Density:
2.67 Watts / Cubic inch.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m) cord AWG#18 wires.
(4) Due to requests in market and advances in technology, specifications subject to change without notice
For the details of safety approval, please consult the factory.
-25-

HES25-033500-1 Related Products

HES25-033500-1 HES25-360100-6 HES25-240150-3 HES25-180166-1 HES25-300120-5 HES25-150200-6 HES25-050400-2 HES25-090270-3 HES25
Description AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES
6ULL-BM140P Base Plate Manual
[color=rgb(37, 37, 37)][backcolor=rgb(255, 255, 255)][font=sans-serif][size=16px][b]MY-IMX6-MB140P 硬件介绍[/b][size=0.87em][size=13.3px][align=center][b]目录[/b][size=12.5px] [[color=rgb(11, 0, 128)][url=h...
明远智睿Lan Integrated technical exchanges
Motor control chip
Is there a control chip that can be used with FAN7388?...
遥遥无期@wxt Motor Drive Control(Motor Control)
Who broke your oscilloscope?
Did you know? Among all the failures of test instruments, hardware problems account for less than 10%! Most of them are due to the lack of regular inspection and maintenance of the instrument and impr...
eric_wang Talking
EEWORLD University Hall----Live Replay: Infineon 1027 Infineon MERUS? Multi-level technology and its advantages of Class D audio amplifier
Live replay: Infineon 1027 Infineon MERUS? Multi-level technology and its advantages of Class D audio amplifier : https://training.eeworld.com.cn/course/5818...
hi5 Talking
After CC2541 is in master mode and searches for slaves to connect, the host can receive the data sent by the slave, but the slave cannot receive the data sent by the master?
After CC2541 master mode (1) searches for slave (2) and connects, the host (1) can receive the data sent by the serial port of the slave (2), but the slave (2) cannot receive the data sent by the seri...
1021256354 Wireless Connectivity
Altiumdesigner 09 import Gerber file with fewer layers
Hey guys, I sent a PCB out for plate making today, but the manufacturer said that the GKO layer was missing. I re-exported it several times, but the GKO layer was still missing. I feel a little depres...
xiaodanbao PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号