DC DC
40 Watts
JCP Series
•
•
•
•
•
•
•
2:1 Input Range
Single, Dual & Triple Outputs
xppower.com
40 °C to +100 °C Operating Temperature
High Efficiency up to 92%
Six sided Metal Case
Fixed 350 kHz Switching Frequency
3 Year Warranty
Input
Input Voltage Range
• 12 VDC (9-18 VDC)
24 VDC (18-36 VDC)
48 VDC (36-75 VDC)
• See table
• Pi network
• Turn on >71% nominal input
Turn off <67% nominal input
General
Efficiency
Isolation Voltage
• See table
• 1500 VDC Input to Output
1500 VDC Input to Case
Output return connected to case
• 350 kHz typical
• >600 kHrs to MIL-HDBK-217F,
GB at 25 º C
• 10
9
min
Input Current
Input Filter
Undervoltage Lockout
Switching Frequency
MTBF
Isolation Resistance
Output
Output Voltage
Output Voltage Trim
Minimum Load
Line Regulation
•
•
•
•
See table
±10%
See table
±0.5% max for single & dual output,
±1.0% max for V1 of triple output,
±3.0% for aux of triple output
±0.5% max single ±1.0% dual output,
±1.0% max for V1 of triple output,
±4.0% for aux of triple output
±1.5% max single and dual
±1.5% max for V1, ±3.0% of triple output
±2.0% max
2.5, 3.3 & 5.0 V models 50 mV pk-pk max
12.0 & 15.0 V models 75 mV pk-pk max
(20 MHz bandwidth)
5% max deviation, recovery to within
1% in 300 µs for a 25% load change
±0.02%/°C
Environmental
Operating Temperature
• -40 °C to +100 °C, derate from 100% load
at +60 °C to 0% load at +100 °C
Case Temperature
Storage Temperature
Cooling
Operating Humidity
Shock
Vibration
•
•
•
•
•
+100 °C max
-55 °C to +125 °C
Convection-cooled
Up to 90%, non-condensing
30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
• 5-500 Hz, 3 g, for 10 mins on each
of 3 axes
Load Regulation
•
Setpoint Accuracy
Voltage Balance
Ripple & Noise
•
•
•
EMC & Safety
Emissions
• EN55022 Level A conducted & radiated
with external components - contact
technical sales
• EN61000-4-2, Level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-6, 3 V rms Perf Criteria A
Transient Response
•
Temperature
•
Coefficient
Overvoltage Protection
• 2.5 V models 3.6 V typical,
3.3 V models 3.9 V typical,
5.0 V models 6.2 V typical,
12.0 V models 15.0 V typical,
15.0 V models 18.0 V typical
Overcurrent Protection
• 110-140%
Short Circuit Protection
• Continuous, trip & restart (Hiccup mode)
Remote On/Off
• ON >3.5 to 75 VDC or open circuit
OFF <1.8 VDC
Thermal Protection
• Shuts down when case temperature
measures +110 °C typical
Remote Sense
• Compensates for up to 10% voltage drop
single output models only
ESD Immunity
Radiated Immunity
Conducted Immunity
Models and Ratings
Input
Voltage
Output
Voltage
2.5
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3 V/±12.0
3.3 V/±15.0
5.0 V/±12.0
5.0 V/±15.0
2.5
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3 V/±12.0
3.3 V/±15.0
5.0 V/±12.0
5.0 V/±15.0
2.5
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3 V/±12.0
3.3 V/±15.0
5.0 V/±12.0
5.0 V/±15.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
Output Current
Min
Max
0A
10.00
0A
10.00
0A
8.80
0A
3.33
0A
2.66
±0.09 A
±1.80
±0.07 A
±1.40
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
0A
10.00
0A
10.00
0A
8.80
0A
3.33
0A
2.66
±0.09 A
±1.80
±0.07 A
±1.40
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
0A
10.00
0A
10.00
0A
8.80
0A
3.33
0A
2.66
±0.09 A
±1.80
±0.07 A
±1.40
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
A/±0.04 A
6.00 A/±0.40
A/±0.03 A
6.00 A/±0.30
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Input Current
(2)
No Load
Full Load
200 mA
2367 mA
200 mA
3090 mA
200 mA
3745 mA
200 mA
3703 mA
200 mA
3702 mA
100 mA
4045 mA
100 mA
3889 mA
200 mA
2784 mA
200 mA
2727 mA
200 mA
3750 mA
200 mA
3611 mA
100 mA
1184 mA
100 mA
1545 mA
110 mA
1831 mA
100 mA
1811 mA
100 mA
1810 mA
100 mA
1978 mA
100 mA
1902 mA
100 mA
1361 mA
100 mA
1333 mA
100 mA
1833 mA
100 mA
1806 mA
50 mA
585 mA
50 mA
764 mA
60 mA
926 mA
60 mA
916 mA
60 mA
906 mA
50 mA
1000 mA
50 mA
962 mA
50 mA
688 mA
50 mA
690 mA
50 mA
938 mA
50 mA
903 mA
Efficiency
88%
89%
89%
90%
90%
89%
90%
88%
88%
88%
90%
88%
89%
91%
92%
92%
91%
92%
90%
90%
90%
90%
89%
90%
90%
91%
92%
90%
91%
89%
87%
88%
90%
JCP
Model
Number
(1)
JCP4012S2V5
JCP4012S3V3
JCP4012S05
JCP4012S12
JCP4012S15
JCP4012D12
JCP4012D15
JCP4012T0312
JCP4012T0315
JCP4012T0512
JCP4012T0515
JCP4024S2V5
JCP4024S3V3
JCP4024S05
JCP4024S12
JCP4024S15
JCP4024D12
JCP4024D15
JCP4024T0312
JCP4024T0315
JCP4024T0512
JCP4024T0515
JCP4048S2V5
JCP4048S3V3
JCP4048S05
JCP4048S12
JCP4048S15
JCP4048D12
JCP4048D15
JCP4048T0312
JCP4048T0315
JCP4048T0512
JCP4048T0515
DC DC
9-18 V
0.60
0.60
0.60
0.60
18-36 V
0.60
0.60
0.60
0.60
36-75 V
0.60
0.60
0.60
0.60
Notes
1. Add suffix ‘ -N’ to model number for negative logic Remote On/Off.
2. Input current measured at nominal input voltage.
2.0 (50.8)
1.10 (27.9)
0.40 (10.2)
0.20 (5.1)
0.40 (10.2)
Mechanical Details
All dimensions are in inches (mm), Tolerance: ±0.02 (±0.5)
Weight:
65 g (0.14 lbs)
PIN CONNECTIONS
Single
Dual
Triple
+V Input
+V Input
+V Input
-V Input
-V Input
-V Input
On/Off
On/Off
On/Off
NC
No Pin
+Aux. Output
-Sense
+V Output 1
Rtn
+Sense
Rtn
-Aux. Output
+Vout
Rtn
+V Output 1
Rtn
-V Output 2
Rtn
Trim
Trim
NC
Pin
1
2
3
4
5
6
7
8
9
BOTTOM
VIEW
9
0.10 (2.5)
0.30 (7.6)
8
7
6
5
4
DIA. 0.04±0.002 (1.0±0.05)
3
2
1
1.80 (45.7)
2.0 (50.8)
0.22 (5.6)
0.60 (15.2)
0.20 (5.1)
0.50 (12.7)
Application Notes
Derating Curve
100
80
Load (%)
0.80 (20.3)
Remote On/Off Control
-2.5%/°C
Remote Sense
If remote sense is not being used:
+Sense should be connected to +Vout
-Sense should be connected to Rtn.
Standard ROF logic is positive.
Output On >3.5 to 75 VDC or open circuit
Output Off <1.8 VDC
Optional ROF logic is negative (‘ -N’ ver-
sion).
Output On <1.8 VDC
Output Off >3.5 to 75 VDC or open circuit
60
40
20
0
-40 -20
0
10
20
30
40
50
60
70
80
90
100
Ambient Temperature (°C), Natural convection, 20 ft/min (0.1 m/s)
Maximum case temperature 100 °C