128Mb: x4, x8, x16
DDR SDRAM
DOUBLE DATA RATE
(DDR) SDRAM
Features
• V
DD
= +2.5V ±0.2V, V
DD
Q = +2.5V ±0.2V
• V
DD
= +2.6V ±0.1V, V
DD
Q = +2.6V ±0.1V (DDR 400)
• Bidirectional data strobe (DQS) transmitted/
received with data, i.e., source-synchronous data
capture (x16 has two – one per byte)
• Internal, pipelined double-data-rate (DDR)
architecture; two data accesses per clock cycle
• Differential clock inputs (CK and CK#)
• Commands entered on each positive CK edge
• DQS edge-aligned with data for READs; center-
aligned with data for WRITEs
• DLL to align DQ and DQS transitions with CK
• Four internal banks for concurrent operation
• Data mask (DM) for masking write data (x16 has two
– one per byte)
• Programmable burst lengths: 2, 4, or 8
• Auto Refresh and Self Refresh Modes
• Longer lead TSOP for improved reliability (OCPL)
• 2.5V I/O (SSTL_2 compatible)
• Concurrent auto precharge option is supported
•
t
RAS lockout supported (
t
RAP =
t
RCD)
OPTIONS
• Configuration
32 Meg x 4 (8 Meg x 4 x 4 banks)
16 Meg x 8 (4 Meg x 8 x 4 banks)
8 Meg x 16 (2 Meg x 16 x 4 banks)
• Plastic Package – OCPL
66-pin TSOP
66-pin TSOP (lead-free)
1
• Plastic Package
60-Ball FBGA (16x9mm)
11
60-Ball FBGA (16x9mm) (lead-free)
1, 11
• Timing – Cycle Time
5ns @ CL = 3 (DDR400)
2, 12
6ns @ CL = 2.5 (DDR333) (FBGA only)
3, 11, 12
6ns @ CL = 2.5 (DDR333) (TSOP only)
3, 4
7.5ns @ CL = 2 (DDR266)
5
7.5ns @ CL = 2 (DDR266A)
6
7.5ns @ CL = 2.5 (DDR266B)
7, 8
• Self Refresh
Standard
Low Power Self Refresh
• Temperature Rating
Standard (0°C to +70°C)
Industrial Temperature (-40°C to +85°C)
MARKING
32M4
16M8
8M16
TG
P
FJ
BJ
-5B
-6
-6T
-75E
-75Z
-75
None
L
None
IT
MT46V32M4 – 8 MEG x 4 x 4 BANKS
MT46V16M8 – 4 MEG x 8 x 4 BANKS
MT46V8M16 – 2 MEG x 16 x 4 BANKS
For the latest data sheet revisions, please refer to the
Micron Web site: www.micron.com/datasheets
Figure 1: Pin Assignment (Top View)
66-pin TSOP
x4
x8
x16
V
DD
V
DD
V
DD
NC
DQ0
DQ0
V
DD
Q V
DD
Q
V
DD
Q
NC
DQ1
NC
DQ0
DQ1
DQ2
V
SS
Q
V
SS
Q
VssQ
NC
DQ3
NC
NC
DQ2
DQ4
V
DD
Q V
DD
Q
V
DD
Q
NC
NC
DQ5
DQ1
DQ3
DQ6
V
SS
Q
V
SS
Q
VssQ
NC
DQ7
NC
NC
NC
NC
V
DD
Q V
DD
Q
V
DD
Q
NC
NC
LDQS
NC
NC
NC
V
DD
V
DD
V
DD
DNU
DNU
DNU
NC
NC
LDM
WE#
WE#
WE#
CAS#
CAS#
CAS#
RAS#
RAS#
RAS#
CS#
CS#
CS#
NC
NC
NC
BA0
BA0
BA0
BA1
BA1
BA1
A10/AP A10/AP A10/AP
A0
A0
A0
A1
A1
A1
A2
A2
A2
A3
A3
A3
V
DD
V
DD
V
DD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
x16
V
SS
DQ15
V
SS
Q
DQ14
DQ13
V
DD
Q
DQ12
DQ11
V
SS
Q
DQ10
DQ9
V
DD
Q
DQ8
NC
V
SS
Q
UDQS
DNU
V
REF
V
SS
UDM
CK#
CK
CKE
NC
NC
A11
A9
A8
A7
A6
A5
A4
V
SS
x8
V
SS
DQ7
V
SS
Q
NC
DQ6
V
DD
Q
NC
DQ5
V
SS
Q
NC
DQ4
V
DD
Q
NC
NC
V
SS
Q
DQS
DNU
V
REF
V
SS
DM
CK#
CK
CKE
NC
NC
A11
A9
A8
A7
A6
A5
A4
V
SS
x4
V
SS
NC
V
SS
Q
NC
DQ3
V
DD
Q
NC
NC
V
SS
Q
NC
DQ2
V
DD
Q
NC
NC
V
SS
Q
DQS
DNU
V
REF
V
SS
DM
CK#
CK
CKE
NC
NC
A11
A9
A8
A7
A6
A5
A4
V
SS
32 MEG x 4
Configuration
Refresh Count
Row Addressing
Bank Addressing
Column Addressing
8 Meg x 4 x 4
banks
4K
4K (A0–A11)
4(BA0,BA1)
2K(A0–A9,A11)
16 MEG x 8
4 Meg x 8 x 4
banks
4K
4K (A0–A11)
4(BA0,BA1)
1K(A0–A9)
8 MEG x 16
2 Meg x 16 x 4
banks
4K
4K (A0–A11)
4(BA0,BA1)
512(A0–A8)
Table 1:
Key Timing Parameters
CLOCK RATE
9
DATA-OUT ACCESS DQS–DQ
SPEED
GRADE CL = 2 CL = 2.5 CL = 3
WINDOW
10
WINDOW SKEW
-5B
-6
6T
-75
133 MHz 167 MHz 200 MHz
133 MHz 167 MHz
133 MHz 167 MHz
100 MHz 133 MHz
N/A
N/A
N/A
N/A
1.6ns
2.1ns
2.0ns
2.5ns
2.5ns
±0.70ns
±0.70ns
±0.70ns
±0.75ns
±0.75ns
+0.40ns
+0.40ns
+0.45ns
+0.50ns
+0.50ns
-75E/75Z 133 MHz 133 MHz
NOTE:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Contact Micron for availability of lead-free products.
Supports PC3200 modules with 3-3-3 timing.
Supports PC2700 modules with 2.5-3-3 timing.
-6T is not available in the x16 configuration.
Supports PC2100 modules with 2-2-2 timing.
Supports PC2100 modules with 2-3-3 timing.
Supports PC2100 modules with 2.5-3-3 timing.
Supports PC1600 modules with 2-2-2 timing.
CL = CAS (READ) latency.
Minimum clock rate @ CL = 2 (-75E, -75Z), CL = 2.5 (-6, -6T, -75),
and CL = 3 (-5B).
11. FBGA package is EOL and no longer available.
12. Not available.
09005aef8074a655
128MBDDRx4x8x16_1.fm - Rev. J 7/04 EN
1
©2000 Micron Technology, Inc. All rights reserved.
128Mb: x4, x8, x16
DDR SDRAM
Figure 2: 128Mb DDR SDRAM Part
Numbers
Example Part Number: MT46V8M16TG-75Z L
-
MT46V
Configuration
Package
Speed
Special
Temperature
Options
Configuration
32 Meg x4
16 Meg x8
8 Meg x16
Package
400 mil TSOP
400 mil TSOP Lead-Free
16x9 FBGA
16x9 FBGA Lead-Free
TG
P
FJ
BJ
-5B
-6
-6T
-75E
-75Z
-75
L
32M4
16M8
8M16
IT
Operating Temp
Standard
Industrial Temp
Special Options
Standard
Low Power
Speed Grade
tCK=5ns, CL = 3
tCK=6ns, CL = 2.5
tCK=6ns, CL = 2.5
tCK=7.5ns, CL = 2
tCK=7.5ns, CL = 2
tCK=7.5ns, CL = 2.5
NOTE:
Not all speeds and all configurations are available in all
packages.
General Description
The 128Mb DDR SDRAM is a high-speed CMOS,
dynamic
random-access
memory
containing
134,217,728 bits. It is internally configured as a quad-
bank DRAM.
The 128Mb DDR SDRAM uses a double data rate
architecture to achieve high-speed operation. The
double data rate architecture is essentially a 2n-
prefetch architecture with an interface designed to
transfer two data words per clock cycle at the I/O pins.
A single read or write access for the 128Mb DDR
SDRAM effectively consists of a single 2n-bit wide,
one-clock-cycle data transfer at the internal DRAM
core and two corresponding
n-bit
wide, one-half-
clock-cycle data transfers at the I/O pins.
A bidirectional data strobe (DQS) is transmitted
externally, along with data, for use in data capture at
the receiver. DQS is a strobe transmitted by the DDR
SDRAM during READs and by the memory controller
during WRITEs. DQS is edge-aligned with data for
READs and center-aligned with data for WRITEs. The
x16 offering has two data strobes, one for the lower
byte and one for the upper byte.
The 128Mb DDR SDRAM operates from a differen-
tial clock (CK and CK#); the crossing of CK going HIGH
and CK# going LOW will be referred to as the positive
edge of CK. Commands (address and control signals)
are registered at every positive edge of CK. Input data
is registered on both edges of DQS, and output data is
referenced to both edges of DQS, as well as to both
edges of CK.
Read and write accesses to the DDR SDRAM are
burst oriented; accesses start at a selected location and
continue for a programmed number of locations in a
programmed sequence. Accesses begin with the regis-
tration of an ACTIVE command, which is then fol-
lowed by a READ or WRITE command. The address
bits registered coincident with the ACTIVE command
are used to select the bank and row to be accessed. The
address bits registered coincident with the READ or
WRITE command are used to select the bank and the
starting column location for the burst access.
The DDR SDRAM provides for programmable READ
or WRITE burst lengths of 2, 4, or 8 locations. An auto
precharge function may be enabled to provide a self-
timed row precharge that is initiated at the end of the
burst access.
As with standard SDR SDRAMs, the pipelined,
multibank architecture of DDR SDRAMs allows for
concurrent operation, thereby providing high effective
bandwidth by hiding row precharge and activation
time.
An auto refresh mode is provided, along with a
power-saving power-down mode. All inputs are com-
patible with the JEDEC Standard for SSTL_2. All full
drive option outputs are SSTL_2, Class II compatible.
NOTE: 1. The functionality and the timing specifica-
tions discussed in this data sheet are for the
DLL-enabled mode of operation.
2. Throughout the data sheet, the various fig-
ures and text refer to DQs as “DQ.” The DQ
term is to be interpreted as any and all DQ
collectively, unless specifically stated other-
wise. Additionally, the x16 is divided into
two bytes, the lower byte and upper byte.
For the lower byte (DQ0 through DQ7) DM
refers to LDM and DQS refers to LDQS. For
the upper byte (DQ8 through DQ15) DM
refers to UDM and DQS refers to UDQS.
3. Complete functionality is described
throughout the document and any page or
diagram may have been simplified to con-
vey a topic and may not be inclusive of all
requirements.
4. Any specific requirement takes precedence
over a general statement.
09005aef8074a655
128MBDDRx4x8x16_1.fm - Rev. J 7/04 EN
2
Micron Technology, Inc., reserves the right to change products or specifications without notice.
©2000 Micron Technology, Inc. All rights reserved.
128Mb: x4, x8, x16
DDR SDRAM
Table of Contents
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Register Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Mode Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Burst Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Burst Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Read Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Operating Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Extended Mode Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Output Drive Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
DLL Enable/Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
DESELECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
NO OPERATION (NOP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
LOAD MODE REGISTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
ACTIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
READ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
PRECHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
BURST TERMINATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
AUTO REFRESH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
SELF REFRESH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Bank/Row Activation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
READs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
WRITEs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
PRECHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Power-down (CKE Not Active) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Data Sheet Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
09005aef8074a655
128MBDDRx4x8x16TOC.fm - Rev. J 7/04 EN
3
Micron Technology, Inc., reserves the right to change products or specifications without notice.
©2000 Micron Technology, Inc. All rights reserved.
128Mb: x4, x8, x16
DDR SDRAM
List of Figures
Figure 1:
Figure 2:
Figure 3:
Figure 4:
Figure 5:
Figure 6:
Figure 7:
Figure 8:
Figure 9:
Figure 10:
Figure 11:
Figure 12:
Figure 13:
Figure 14:
Figure 15:
Figure 16:
Figure 17:
Figure 18:
Figure 19:
Figure 20:
Figure 21:
Figure 22:
Figure 23:
Figure 24:
Figure 25:
Figure 26:
Figure 27:
Figure 28:
Figure 29:
Figure 30:
Figure 31:
Figure 32:
Figure 33:
Figure 34:
Figure 35:
Figure 36:
Figure 37:
Figure 38:
Figure 39:
Figure 40:
Figure 41:
Figure 42:
Figure 43:
Figure 44:
Figure 45:
Figure 46:
Figure 47:
Figure 48:
Figure 49:
Figure 50:
Figure 51:
Figure 52:
Figure 53:
Figure 54:
Figure 55:
Pin Assignment (Top View) 66-pin TSOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
128Mb DDR SDRAM Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Functional Block Diagram 32 Meg x 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Functional Block Diagram 16 Meg x 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Functional Block Diagram 8 Meg x 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Ball Assignment (Top View) 60-Ball FBGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Mode Register Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
CAS Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Extended Mode Register Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Activating a Specific Row in a Specific Bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Example: Meeting
t
RCD (
t
RRD) MIN When 2 <
t
RCD (
t
RRD) MIN/
t
CK≤3 . . . . . . . . . . . . . . . . . . . . . .19
READ Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
READ Burst. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Consecutive READ Bursts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Nonconsecutive READ Bursts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Random READ Accesses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Terminating a READ Burst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
READ to WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
READ to PRECHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
WRITE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
WRITE Burst. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Consecutive WRITE to WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Nonconsecutive WRITE to WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Random WRITE Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
WRITE to READ - Uninterrupting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
WRITE to READ - Interrupting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
WRITE to READ - Odd Number of Data, Interrupting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
WRITE to PRECHARGE - Uninterrupting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
WRITE to Precharge – Interrupting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
WRITE to PRECHARGE Odd Number of Data, Interrupting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
PRECHARGE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Power-Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Input Voltage Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
SSTL_2 Clock Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Derating Data Valid Window (
t
QH -
t
DQSQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Full Drive Pull-Down Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Full Drive Pull-Up Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Reduced Drive Pull-Down Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Reduced Drive Pull-Up Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
x4, x8 Data Output Timing –
t
DQSQ,
t
QH, and Data Valid Window . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
x16 Data Output Timing –
t
DQSQ,
t
QH, and Data Valid Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Data Output Timing –
t
AC and
t
DQSCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Data Input Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Initialization Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Initialize And Load Mode Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Power-Down Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Auto Refresh Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Self Refresh Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Bank Read - Without Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Bank Read - With Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Bank Write - Without Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Bank Write - With Auto Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Write - DM Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
66-Pin Plastic TSOP (400 mil). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
60-Ball FBGA (16 x 9mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
09005aef8074a655
128MBDDRx4x8x16LOF.fm - Rev. J 7/04 EN
4
Micron Technology, Inc., reserves the right to change products or specifications without notice.
©2000 Micron Technology, Inc. All rights reserved.
128Mb: x4, x8, x16
DDR SDRAM
List of Tables
Table 1:
Table 2:
Table 3:
Table 4:
Table 5:
Table 6:
Table 7:
Table 8:
Table 9:
Table 10:
Table 11:
Table 12:
Table 13:
Table 14:
Table 15:
Table 16:
Table 17:
Table 18:
Table 19:
Table 20:
Table 21:
Table 22:
Table 23:
Table 24:
Table 25:
Table 26:
Table 27:
Table 28:
Table 29:
Table 30:
Key Timing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Ball/Pin Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Reserved NC Balls and Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Burst Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
CAS Latency (CL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Truth Table – Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Truth Table – DM Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Truth Table – CKE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Truth Table – Current State Bank
n
- Command to Bank
n. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Truth Table – Current State Bank
n
- Command to Bank
m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
DC Electrical Characteristics and Operating Conditions (-6, -6T, -75E, -75Z, -75) . . . . . . . . . . . . . . .46
DC Electrical Characteristics and Operating Conditions (-5B DDR400) . . . . . . . . . . . . . . . . . . . . . . . .47
AC Input Operating Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Clock Input Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Capacitance (x4, x8 TSOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Capacitance (x4, x8 FBGA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Capacitance (x16 TSOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
I
DD
Specifications and Conditions (x4, x8; -5B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
I
DD
Specifications and Conditions (x4, x8; -6/-6T/-75E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
I
DD
Specifications and Conditions (x4, x8; -75Z/-75) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
I
DD
Specifications and Conditions (x16; -6/-6T/-75E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
I
DD
Specifications and Conditions (x16; -75Z/-75) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
I
DD
Test Cycle Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Electrical Characteristics and Recommended AC Operating Conditions (-5B) . . . . . . . . . . . . . . . . . .57
Electrical Characteristics and Recommended AC Operating Conditions (-6/-6T/-75E) . . . . . . . . . .58
Electrical Characteristics and Recommended AC Operating Conditions (-75Z/-75) . . . . . . . . . . . . .59
Input Slew Rate Derating Values for Addresses and Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Input Slew Rate Derating Values for DQ, DQS, and DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Normal Output Drive Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Reduced Output Drive Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
09005aef8074a655
128MBDDRx4x8x16LOT.fm - Rev. J 7/04 EN
5