H HiTRON
PCB-MOUNT DC-DC CONVERTER ENCAPSULATED MODULES
INDUSTRIAL GRADE 10 WATTS SINGLE & DUAL OUTPUT
HDM11-S & HDM11-D SERIES
FEATURES:
VERY LOW PROFILE 7 MM HIGH
SINGLE & DUAL OUTPUT
WIDE 4:1 INPUT RANGE
10W ISOLATED OUTPUT
SIX-SIDED METAL SHIELD
SPECIFICATION
INPUT SPECIFICATION
Input Range:
Wide 4:1 DC input range.
See Ratings Chart.
Input Voltage:
Nominal 12/24/48Vdc.
Input Current:
Various with input range and load.
See Ratings Chart.
Input Fuse:
Use external fuse.
Input Filter:
Pi-Network.
Undervoltage Shutdown:
8Vdc.
Isolation Resistor:
1,000 Mega Ohms.
Isolation Voltage:
1,500Vdc.
EMI:
Six-sided metal shielding.
Remote On/Off:
TTL/CMOS-Compatible Input Control.
Positive Logic
version for Standard set up:
ON(Enable)=Open(or
2.5-5.0Vdc above-Vin)
OFF(Disable)=Short(or
0-0.8Vdc above-Vin)
Negative Logic
version option available by adding a
“N”
suffix to the end of Model #.
Remark: Logic voltage refer to –Input(Vin).
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Voltage Accuracy:
Main O/P ±2.0% typical.
Line Regulation:
Various with output voltages ±0.5% typ.
Load Regulation:
Various with output voltages.
Single O/P ±1.0 typical.
Dual O/P ±2.0 typical.
Noise & Ripple:
Typical 100mV for 3.3V/5.0V & 1.0%
for others peak to peak.
OVP:
Built-in on main output.
Adjustability:
Not available.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set t about 120-150% of rating output load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency:
78% typical various with input.
Switching Frequency:
Fixed frequency 450K Hz.
Circuit Topology:
450K Hz. Forward Circuit.
Transient Response:
Peak deviation 200mV.
Recovery time < 3mS for a 25% load change.
Case:
Black coated aluminum with non-conductive
metal base.
Power Density:
17.2Watts. / Cubic inch.
MTBF:
1,000,000 hours. Mil. Std. 217, 25°C.
Operating Temperature:
-25°C to +85°C range.
–10°C to+70°C @ full load without derating.
From+70°C, derating linearly to half load @+85°C.
(Refer to Derating Chart).
Storage Temperature:
-40°C to +105°C.
Humidity:
Up to 95% RH, Non-condensing.
Temperature Coefficient:
0.02% /°C.
Cooling:
Convection cooling up to 70°C @ full load.
At least 100LFM moving air is recommended for
full load >+70°C in a confined area.
Industrial Grade only.
NOTE:(1)
All measurements are at nominal input, full load and +25°C unless otherwise specified.
(2) Line Regulation measured from High to Low Lines at full load.
(3) Load Regulation measured from Full Load (F-L) to Half-Load (H-L) at nominal input.
(4) Correct fuse size by calculating the max. DC current drains at low Line input & Load and then adding 20-25% for the desired fuse size.
Due to requests in market and advances in technology, specifications subject to change without notice.