Signal conditioned precision pressure transducers
FEATURES
· 0...5 to 0...50 mbar, 0...1 to 0...20 "H
2
O
gage or differential pressure
(custom calibrations available)
· 0...5 V output
· Single power supply
· Internal supply regulation
· Precision temperature
compensated and calibrated
SERVICE
Non-corrosive, non-ionic working fluids,
such as dry air and dry gases
Scale:
1 cm
1 inch
SPECIFICATIONS
Maximum ratings
Supply voltage
Maximum load current
source
sink
Temperature limits
Storage
Operating
Compensated
Lead temperature (10 sec soldering)
Humidity limits
pressure inlets only
Proof pressure
1
144LP...-PCB
144LU...-PCB
Common mode pressure
144LP...-PCB
144LU...-PCB
7.5...24 V
20 mA
10 mA
-25 to 85°C
-10 to 70°C
0 to 50°C
300°C
0 - 95 %RH
300 mbar
4 psi
600 mbar
8 psi
ELECTRICAL CONNECTION
+Vs
7.5 V to 24 V
144L...-PCB
Vout
V
-Vs
Januar 2005 / 004
1/4
www.sensortechnics.com
144L...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
(unless otherwise noted V
S
= 8 V, R
L
> 100 kΩ, t
amb
= 25°C)
Ω
Characteristics
Operating pressure
2
144LP05D-PCB
144LP10D-PCB
144LP20D-PCB
144LP50D-PCB
144LU01D-PCB
144LU02D-PCB
144LU05D-PCB
144LU10D-PCB
144LU20D-PCB
Min.
0
0
0
0
0
0
0
0
0
-0.05
4.9
Typ.
Max.
5
10
20
50
1
2
5
10
20
Unit
mbar
"H
2
O
Zero pressure offset
Full scale output
Full scale span
3
Thermal effects (0 to 50°C)
4
Offset
144LU01D-PCB
144LU02D-PCB
144LP05D-PCB
all other devices
144LU01D-PCB
all other devices
0
5.0
5.0
±0.05
±0.02
±0.02
±0.01
±0.05
±0.02
0.1
±0.2
200
0.05
5.1
±0.15
±0.07
±0.07
±0.03
±0.10
±0.04
0.5
V
%FSO/°C
Span
Non-linearity and hysteresis (BSL)
5
Long term stability
6
Response time (10 to 90%)
Position sensitivity
Current consumption
Power supply rejection
Offset
Span
%FSO
µs
%FSO/g
mA
%FSO/V
144LU01D-PCB
all other devices
0.5
0.1
4.2
0.05
0.03
Specification notes:
1.
2.
3.
4.
5.
6.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
The output signal is proportional to the pressure applied to port B, relative to port A, e.g. the output signal increases when
vacuum is applied to port A relative to port B.
Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
Non-linearity refers to the
Best Straight Line
fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
Thermal effects tested and guaranteed from 0 to 50°C relative to 25°C. All specifications shown are relative to 25°C.
Change in output after one year or 1 million pressure cycles.
2/4
Januar 2005 / 004
www.sensortechnics.com
144L...-PCB Series
Signal conditioned precision pressure transducers
ORDERING INFORMATION
Operating pressure
0...5 mbar
0...10 mbar
0...20 mbar
0...50 mbar
0...1 "H
2
O
0...2 "H
2
O
0...5 "H
2
O
0...10 "H
2
O
0...20 "H
2
O
Order number
144LP05D-PCB
144LP10D-PCB
144LP20D-PCB
144LP50D-PCB
144LU01D-PCB
144LU02D-PCB
144LU05D-PCB
144LU10D-PCB
144LU20D-PCB
Custom calibrations available
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of
the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights
of others.
4/4
Januar 2005 / 004
www.sensortechnics.com