No. STSE-CL6143A
<Cat.No.061228>
SPECIFICATIONS FOR NICHIA
PINK
MODEL :
NSPBR70ASS-N9
LED
NICHIA CORPORATION
-0-
Nichia STSE-CL6143A
<Cat.No.061228>
1.SPECIFICATIONS
(1) Absolute Maximum Ratings
Item
Forward Current
Pulse Forward Current
Reverse Voltage
Power Dissipation
Operating Temperature
Storage Temperature
Soldering Temperature
I
FP
Conditions
:
Symbol
I
F
I
FP
V
R
P
D
T
opr
T
stg
T
sld
and
Absolute Maximum Rating
35
100
5
147
-30 ~ + 85
-40 ~ +100
265°C for 5sec.
Duty
<
1/10
=
(Ta=25°C)
Unit
mA
mA
V
mW
°C
°C
Pulse Width
<
10msec.
=
(2) Initial Electrical/Optical Characteristics
Item
Symbol
Forward Voltage
V
F
Reverse Current
I
R
Luminous Flux
φ
V
x
-
Chromaticity Coordinate
y
-
Please refer to CIE 1931 chromaticity diagram.
Condition
I
F
=30[mA]
V
R
= 5[V]
I
F
=30[mA]
I
F
=30[mA]
I
F
=30[mA]
Typ.
(3.8)
-
(2.9)
0.420
0.268
(Ta=25°C)
Max.
Unit
4.2
V
50
µA
-
lm
-
-
-
-
(3) Ranking
Item
Luminous Flux
Rank Rb
Rank Ra
Rank R1
Symbol
φ
V
φ
V
φ
V
Condition
I
F
=30[mA]
I
F
=30[mA]
I
F
=30[mA]
Min.
3.4
2.4
1.7
(Ta=25°C)
Max.
Unit
4.8
lm
3.4
lm
2.4
lm
Luminous Flux Measurement allowance is ± 10%.
Color Ranks
x
y
x
y
0.350
0.190
0.420
0.243
Rank N921
0.350
0.385
0.240
0.266
Rank N923
0.420
0.455
0.293
0.319
0.385
0.216
0.455
0.269
x
y
x
y
0.385
0.216
0.455
0.269
(I
F
=30mA,Ta=25°C)
Rank N922
0.385
0.420
0.420
0.266
0.293
0.243
Rank N924
0.455
0.490
0.319
0.345
0.490
0.295
Color Coordinates Measurement allowance is ± 0.01.
-1-
Nichia STSE-CL6143A
<Cat.No.061228>
2.INITIAL
OPTICAL/ELECTRICAL
CHARACTERISTICS
Please refer to figure’s page.
3.OUTLINE
DIMENSIONS
AND
MATERIALS
Epoxy Resin (over Silicone Resin + Phosphor)
Ag plating Copper Alloy
Please refer to figure’s page.
Material as follows ;
Resin(Mold) :
Leadframe :
4.PACKAGING
· The LEDs are packed in cardboard boxes after packaging in stick.
Please refer to figure’s page.
The label on the packing unit shows ; Part Number, Lot Number, Ranking, Quantity
· In order to protect the LEDs from mechanical shock, we pack them in cardboard boxes for transportation.
· The LEDs may be damaged if the boxes are dropped or receive a strong impact against them,
so precautions must be taken to prevent any damage.
· The boxes are not water resistant and therefore must be kept away from water and moisture.
· When the LEDs are transported, we recommend that you use the same packing method as Nichia.
5.LOT
NUMBER
The first six digits number shows
lot number.
The lot number is composed of the following characters;
-
- Year
( 6 for 2006, 7 for 2007 )
- Month ( 1 for Jan., 9 for Sep., A for Oct.,
- Nichia's Product Number
- Ranking by Color Coordinates
- Ranking by Luminous Flux
B for Nov. )
-2-
Nichia STSE-CL6143A
<Cat.No.061228>
6.RELIABILITY
(1) TEST ITEMS AND RESULTS
Test Item
Resistance to
Soldering Heat
Solderability
Thermal Shock
Temperature Cycle
Moisture Resistance Cyclic
Terminal Strength
(bending test)
Terminal Strength
(pull test)
High Temperature Storage
Temperature Humidity
Storage
Low Temperature Storage
Steady State Operating Life
Condition 1
Steady State Operating Life
Condition 2
Steady State Operating Life
of High Humidity Heat
Steady State Operating Life
of Low Temperature
Standard
Test Method
JEITA ED-4701
300 302
JEITA ED-4701
300 303
JEITA ED-4701
300 307
JEITA ED-4701
100 105
JEITA ED-4701
200 203
JEITA ED-4701
400 401
JEITA ED-4701
400 401
JEITA ED-4701
200 201
JEITA ED-4701
100 103
JEITA ED-4701
200 202
Test Conditions
Tsld=260 ± 5°C, 5sec.
1.6mm from the base of the stopper
(Pre treatment 30°C,70%,168hrs.)
Tsld=235 ± 5°C,
(using flux)
0°C ~ 100°C
15sec. 15sec.
-40°C ~ 25°C ~ 100°C ~ 25°C
30min. 5min. 30min. 5min.
25°C ~ 65°C ~ -10°C
90%RH 24hrs./1cycle
Load 5N (0.5kgf)
0° ~ 90° ~ 0° bend 2 times
Load 10N (1kgf)
10 ± 1 sec.
Ta=100°C
Ta=60°C,
Ta=-40°C
Ta=25°C,
Ta=35°C,
I
F
=35mA
I
F
=30mA
I
F
=20mA
RH=90%
5sec.
Note
1 time
Number of
Damaged
0/50
1 time
over 95%
100 cycles
100 cycles
10 cycles
No noticeable
damage
No noticeable
damage
1000hrs.
1000hrs.
1000hrs.
1000hrs.
1000hrs.
500hrs.
1000hrs.
0/50
0/50
0/50
0/50
0/50
0/50
0/50
0/50
0/50
0/50
0/50
0/50
0/50
60°C, RH=90%,
Ta=-30°C,
I
F
=30mA
(2) CRITERIA FOR JUDGING DAMAGE
Criteria for Judgement
Item
Symbol Test Conditions
Min.
Max.
Forward Voltage
V
F
I
F
=30mA
-
U.S.L.*) 1.1
Reverse Current
I
R
V
R
=5V
-
U.S.L.*) 2.0
Luminous Flux
I
F
=30mA
L.S.L.**) 0.7
-
φ
V
*) U.S.L. : Upper Standard Level
**) L.S.L. : Lower Standard Level
-3-
Nichia STSE-CL6143A
<Cat.No.061228>
7.CAUTIONS
The LEDs are devices which are materialized by combining Blue LEDs and special phosphors.
Consequently, the color of the LEDs is changed a little by an operating current.
Care should be taken after due consideration when using LEDs.
(1) Storage
· Storage Conditions
Before opening the package :
The LEDs should be kept at 30°C or less and 90%RH or less. The LEDs should be used within a
year.
When storing the LEDs, moisture proof packaging with absorbent material (silica gel)
is recommended.
After opening the package :
The LEDs should be kept at 30°C or less and 70%RH or less.
The LEDs should be soldered
within 168 hours (7days) after opening the package.
If unused LEDs remain, they should be
stored in moisture proof packages, such as sealed containers with packages of moisture absorbent
material (silica gel). It is also recommended to return the LEDs to the original moisture proof bag
and to reseal the moisture proof bag again.
· If the moisture absorbent material (silica gel) has faded away or the LEDs have exceeded the storage
time, baking treatment should be performed using the following conditions.
Baking treatment : more than 24 hours at 85°C
· Nichia LED leadframes are silver plated copper alloy. The silver surface may be affected by
environments which contain corrosive substances. Please avoid conditions which may cause the LED
to corrode, tarnish or discolor. This corrosion or discoloration may cause difficulty during soldering
operations. It is recommended that the LEDs be used as soon as possible.
· Please avoid rapid transitions in ambient temperature, especially, in high humidity environments where
condensation can occur.
(2) Static Electricity
· Static electricity or surge voltage damages the LEDs.
It is recommended that a wrist band or an anti-electrostatic glove be used when handling the LEDs.
· All devices, equipment and machinery must be properly grounded. It is recommended that precautions
be taken against surge voltage to the equipment that mounts the LEDs.
· When inspecting the final products in which LEDs were assembled, it is recommended to check
whether the assembled LEDs are damaged by static electricity or not.
It is easy to find
static-damaged LEDs by a light-on test or a VF test at a lower current (below 1mA is recommended).
· Damaged LEDs will show some unusual characteristics such as the leak current remarkably
increases, the forward voltage becomes lower, or the LEDs do not light at the low current.
Criteria : (V
F
> 2.0V at I
F
=0.5mA)
-4-