S101N11/S101N12/S201N11/S201N12
S101N11/S101N12
S201N11/S201N12
s
Features
1. Built-in snubber circuit
2. Input side voltage operation type
3. Built-in zero-cross circuit
(S101N12/S201N12)
4. RMS ON-state current I
T
: MAX. 1.6Arms
Voltage Input Type
Solid State Relay
with Built-in Snubber Circuit
s
Outline Dimensions
26.0
MAX.
(Unit : mm)
5.5
MAX.
Lot No.
21.0
MAX.
(DIN Standard)
S101N11
INPUT
OUTPUT
1.6A120VAC
s
Applications
1. Programmable controllers
2. Copiers
3. Air conditioners
4. Automatic vending machines
−+
3.5
±0.5
5 VD C
∼
2.54
2.54
10.16
7.62
0.5
1.3
±0.3
Model No.
S101N11
S101N12
S201N11
S201N12
s
Model line-ups
No zero-cross circuit
Built-in zero-cross circuit
For 100V lines
S101N11
S101N12
For 200V lines
S201N11
S201N12
4 3
2
1
Internal connection diagram
S101N11/S201N11
S101N12/S201N12
s
Absolute Maximum Ratings
Input
Parameter
Symbol
Input signal voltage
V
IN
Reverse voltage
V
R
S101N11
Standard
S101N12
−
voltage
S201N11
S201N12
Operating frequency
f
S101N11
Output
S101N12
supply
voltage
S201N11
S201N12
RMS ON-state current
*2
Peak one cycle surge current
Operating temperature
Storage temperature
*3
Isolation voltage
*4
Soldering temperature
Rating
3 to 6
6
120
V
V
V
rms
240
4 3
2
1
4 3
Z.C.
2
(Ta=25°C)
Unit
1
1
47 to 63
60 to 140
Hz
2
3
4
Output
Output (Triac T1)
Output (Triac T2)
Input (+)
Input (−)
Z.C. : Zero-cross circuit
1
Output (Triac T1)
2
Output (Triac T2)
3
Input (+)
4
Input (−)
V
out
60 to 280
I
T
I
surge
T
opr
T
stg
V
iso
T
sol
1.6
15
−25
to
+80
−30
to
+85
3.0
260
*1
V
rms
g
Unspecified tolerance :
±0.4mm
A
rms
A
°C
°C
kV
rms
°C
*1 Refer to Fig.1
*2 50Hz sine wave, start at Tj=25°C
*3 Isolation voltage measuring method
(1) Dielectric withstand voltage tester with zero cross circuit shall be used.
(2) The applied voltage waveform shall be sine wave.
(3) Voltage shall be applied between input and output.
(Input and output terminals shall be shorted respectively.)
(4) AC 60Hz, 1min, 40 to 60%RH.
*4 For 5s
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/
Application Circuits
NOTICE
qThe
circuit application examples in this publication are provided to explain representative applications of
SHARP devices and are not intended to guarantee any circuit design or license any intellectual property
rights. SHARP takes no responsibility for any problems related to any intellectual property right of a
third party resulting from the use of SHARP's devices.
qContact
SHARP in order to obtain the latest device specification sheets before using any SHARP device.
SHARP reserves the right to make changes in the specifications, characteristics, data, materials,
structure, and other contents described herein at any time without notice in order to improve design or
reliability. Manufacturing locations are also subject to change without notice.
qObserve
the following points when using any devices in this publication. SHARP takes no responsibility
for damage caused by improper use of the devices which does not meet the conditions and absolute
maximum ratings to be used specified in the relevant specification sheet nor meet the following
conditions:
(i) The devices in this publication are designed for use in general electronic equipment designs such as:
--- Personal computers
--- Office automation equipment
--- Telecommunication equipment [terminal]
--- Test and measurement equipment
--- Industrial control
--- Audio visual equipment
--- Consumer electronics
(ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and
safety when SHARP devices are used for or in connection with equipment that requires higher
reliability such as:
--- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
--- Traffic signals
--- Gas leakage sensor breakers
--- Alarm equipment
--- Various safety devices, etc.
(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely
high level of reliability and safety such as:
--- Space applications
--- Telecommunication equipment [trunk lines]
--- Nuclear power control equipment
--- Medical and other life support equipment (e.g., scuba).
qContact
a SHARP representative in advance when intending to use SHARP devices for any "specific"
applications other than those recommended by SHARP or when it is unclear which category mentioned
above controls the intended use.
qIf
the SHARP devices listed in this publication fall within the scope of strategic products described in the
Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export
such SHARP devices.
qThis
publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under
the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any
means, electronic or mechanical, for any purpose, in whole or in part, without the express written
permission of SHARP. Express written permission is also required before any use of this publication
may be made by a third party.
qContact
and consult with a SHARP representative if there are any questions about the contents of this
publication.
115