SIDACtor®
Device
RoHS
¨
DO-214AA
SIDACtor
solid state protection devices protect telecommunications equipment
such as modems, line cards, and CPE (telephones, answering machines, and fax
machines).
SIDACtor
devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
P0080S_L
P0220S_L
P0300S_L
P0640S_L
P0720S_L
P0900S_L
P1100S_L
P1300S_L
P1500S_L
P1800S_L
P2100S_L
P2300S_L
P2600S_L
P3100S_L
P3500S_L
V
DRM
Volts
6
15
25
58
65
75
90
120
140
170
180
190
220
275
320
V
S
Volts
25
32
40
77
88
98
130
160
180
220
240
260
300
350
400
V
T
Volts
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
I
DRM
µAmps
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
I
S
mAmps
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
I
T
Amps
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
I
H
mAmps
50
50
50
150
150
150
150
150
150
150
150
150
150
150
150
*
“L” in part number indicates RoHS compliance.
For non-RoHS compliant device, delete “L” from part number.
For individual “SA”, “SB”, and “SC” surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. I
PP
applies to -40 °C through +85 °C temperature range.
• I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
• Listed
SIDACtor
devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• V
DRM
is measured at I
DRM.
• V
S
is measured at 100 V/µs.
• Special voltage (V
S
and V
DRM
) and holding current (I
H
) requirements are available upon request.
Surge Ratings in Amps
I
PP
Series
0.2x310 * 2x10 *
8x20 *
0.5x700 ** 2x10 ** 1.2x50 **
Amps
A
B
C
20
25
50
Amps
150
250
500
Amps
150
250
400
10x160 *
10x160 **
Amps
90
150
200
10x560 *
10x560 **
Amps
50
100
150
5x320 *
9x720 **
Amps
75
100
200
10x360 * 10x1000 * 5x310 *
I
TSM
10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
Amps
75
125
175
Amps
45
80
100
Amps
75
100
200
Amps
20
30
30
di/dt
Amps/µs
500
500
500
* Current waveform in µs
** Voltage waveform in µs
www.littelfuse.com
3-2
© 2006 Littelfuse • Telecom Design Guide
SIDACtor® Device
Thermal Considerations
Package
DO-214AA
Symbol
T
J
T
S
R
θJA
Parameter
Operating Junction Temperature Range
Storage Temperature Range
Thermal Resistance: Junction to Ambient
Value
-40 to +150
-65 to +150
90
Unit
°C
°C
°C/W
Capacitance Values
pF
Part Number *
P0080S[A/B]L
P0080SCL
P0220SAL
P0220SBL
P0220SCL
P0300S[A/B]L
P0300SCL
P0640S[A/B]L
P0640SCL
P0720SAL
P0720SBL
P0720SCL
P0900SAL
P0900SBL
P0900SCL
P1100SAL
P1100SBL
P1100SCL
P1300SAL
P1300SBL
P1300SCL
P1500SAL
P1500SBL
P1500SCL
P1800SAL
P1800SBL
P1800SCL
P2100S[A/B]L
P2100SCL
P2300SAL
P2300SBL
P2300SCL
P2600SAL
P2600SBL
P2600SCL
P3100SAL
P3100SBL
P3100SCL
P3500SAL
P3500SBL
P3500SCL
MIN
25
35
25
25
30
15
25
40
55
35
35
50
35
35
45
30
30
45
25
25
40
25
25
35
25
25
35
20
30
25
25
30
20
20
30
20
20
30
20
20
25
MAX
150
260
150
150
240
140
250
60
155
60
75
150
55
70
140
50
70
115
45
60
105
40
55
95
35
50
90
35
90
35
50
80
35
45
80
35
45
70
35
40
65
* [A/B] in part number indicates that values are for both A and B surge ratings.
Note: Off-state capacitance (C
O
) is measured at 1 MHz with a 2 V bias.
Telecom Design Guide • © 2006 Littelfuse
3-3
www.littelfuse.com
SIDACtor Devices
SIDACtor® Device
+I
t
r
= rise time to peak value
t
d
= decay time to half value
I
T
I
S
I
H
I
DRM
-V
V
T
V
DRM
V
S
+V
I
PP
– Peak Pulse Current – %I
PP
100
Peak
Value
Waveform = t
r
x t
d
50
Half Value
0
0
t
r
t
d
t – Time (µs)
-I
V-I Characteristics
t
r
x t
d
Pulse Waveform
Percent of V
S
Change – %
10
I
H
(T
C
= 25 ˚C)
14
12
8
6
4
2
0
-4
-6
-8
-40 -20
0
20 40 60 80 100 120 140 160
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
-40 -20 0
20 40 60 80 100 120 140 160
I
H
25 ˚C
25 ˚C
Ratio of
Case Temperature (T
C
) – ˚C
Junction Temperature (T
J
) – ˚C
Normalized V
S
Change versus Junction Temperature
Normalized DC Holding Current versus Case Temperature
www.littelfuse.com
3-4
© 2006 Littelfuse • Telecom Design Guide