125W Single Output with PFC Function
Features :
PPS-125
series
Universal AC input / Full range
Built-in active PFC function
Protections:Short circuit/Over load/Over voltage
PWM control and regulated
Built-in remote sense function
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
High power density 6.117W/inch
3
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
PPS-125-3.3
3.3V
20A
PPS-125-5
5V
20A
0 ~ 20A
0 ~ 25A
100W
125W
100mVp-p
4.75 ~ 5.25V
2.0%
0.5%
1.0%
127 ~ 370VDC
PF>0.98/115VAC at full load
80%
80%
80%
83%
83%
83%
PPS-125-12
12V
8.5A
0 ~ 8.5A
0 ~ 10.5A
102W
126W
100mVp-p
PPS-125-13.5 PPS-125-15
13.5V
7.5A
0 ~ 7.5A
0 ~ 9.3A
101.25W
125.55W
100mVp-p
15V
6.7A
0 ~ 6.7A
0 ~ 8.4A
100.5W
126W
100mVp-p
PPS-125-24
24V
4.2A
0 ~ 4.2A
0 ~ 5.2A
100.8W
124.8W
150mVp-p
PPS-125-27
27V
3.8A
0 ~ 3.8A
0 ~ 4.6A
102.6W
124.2W
150mVp-p
PPS-125-48
48V
2.1A
0 ~ 2.1A
0 ~ 2.6A
100.8W
124.8W
250mVp-p
CURRENT RANGE (convection)
0 ~ 20A
CURRENT RANGE (18CFM FAN)
0 ~ 25A
RATED POWER (convection)
66W
OUTPUT
RATED POWER (18CFM FAN)
82.5W
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE ADJ. RANGE
3.13 ~ 3.46V
VOLTAGE TOLERANCE
Note.3
2.0%
11.40 ~ 12.60V 12.82 ~ 14.17V 14.25 ~ 15.75V 22.80 ~ 25.20V 25.65 ~ 28.35V 45.60 ~ 50.40V
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
0.5%
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
INPUT
EFFICIENCY (Typ.)
AC CURRENT
115VAC
230VAC
INRUSH CURRENT (max.)
0.5%
1.0%
90 ~ 264VAC
47~63Hz
PF>0.93/230VAC
70%
1.2A
0.5%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
1.0%
1000ms, 30ms, 20ms/230VAC
2000ms, 30ms, 20ms/115VAC at full load
79%
1.7A
0.6A
0.75A
COLD START 40A/230VAC
<2mA / 240VAC
130 ~ 160% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
3.63 ~ 4.45V 5.5 ~ 6.75V
13.8 ~ 16.2V 15.5 ~ 20.25V 17.25 ~ 20.25V 27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
LEAKAGE CURRENT
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
(Note 4)
31.05 ~ 36.45V 57.6 ~ 67.2V
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
111.7Khrs min. MIL-HDBK-217F (25 )
OTHERS
DIMENSION
PACKING
127*76.2*34.6mm (L*W*H)
0.37Kg; 36pcs/13.3Kg/0.89CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.